• Title/Summary/Keyword: conductivity measurement

Search Result 627, Processing Time 0.026 seconds

Development and characterization of graphite reinforced conductive polymer composites for PEMFC bipolar plates (고분자전해질 연료전지용 흑연계 복합소재 분리판 개발)

  • Heo Seongil;Yun Jincheol;Oh Kyeongseok;Han Kyungseop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.248-251
    • /
    • 2005
  • Graphite reinforced conductive polymer composites for PEMFC bipolar plates were fabricated by the compression molding technique. Graphite powder was mixed with an phenol resin to impart electrical property in composites. In this study, conductive polymer composites with high filler $loadings(>60wt.\%)$ were manufactured to accomplish high electrical conductivity above 100S/cm. The level of compaction is important because graphite powder increase electrical conductivity of composites by direct physical contact between particles. The optimum molding pressure according to filler was proposed experimentally. Various tests(electrical conductivity, flexural strength, compressive strength, leach test, etc) were carried out to verify the performance of fabricated composites for PEMFC bipolar plates. Fabricated composites have good electrical conductivity and mechanical strength. The results of leach test and contact angle measurement showed similar characteristics compared with commercial bipolar plates.

  • PDF

Estimation of grain size data from the hydraulic conductivity (투수계수로부터 입도분포 자료의 추정)

  • Nkomozepi, Temba;Chung, Sang-Ok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.29
    • /
    • pp.29-35
    • /
    • 2011
  • The relationship between hydrologic processes and scale is one of the more complex issues in surface water hydrology. Disturbances that change vegetation and/or soil properties have been known to subsequently alter the landscape. The primary objective of this study was to estimate the grain size of soils with different properties from the hydraulic conductivity using pedotransfer functions. The double ring infiltrometer method was used to measure the vertical hydraulic conductivity of three soils under different soil planar surface treatments. Seven selected pedotransfer functions were used to estimate percentile diameters and the reduction in infiltration caused by compaction was misconstrued as caused by changes in percentile diameter. Results showed that compaction on the sandy loamy foot paths reduced the hydraulic conductivity by about 50%. The study showed that perceptual models of infiltration processes and appreciation of scale problems in modeling are far more sophisticated than normally presented in texts. Hydraulic measurement methods are still relevant and will provide significant information of grain size of the soils.

  • PDF

Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials (목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.2
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

An Experimental Study on the Measurement of Electrical Conductivity of Cementitious Composites According to the Type of Steel Fiber (강섬유 종류에 따른 시멘트 복합체의 전기전도도 측정에 대한 실험적 연구)

  • Lee, Yae-Chan;Kim, Gyu-Yong;Nam, Jeong-Soo;Lee, Sang-Kyu;Shu, Dong-Kyun;Eu, Ha-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.191-192
    • /
    • 2020
  • The purpose of this study is to measure the electrical conductivity of cementitious composites as an early step to obtain shielding performance by mixing various type of steel fiber into cementitious composites, the main building material of protection facility, to shield electromagnetic pulse (EMP) damage. Fiber such as conductors as amorphous metallic fiber, hooked steel fiber, and smooth steel fiber are mixed into cementitious composites to give electrical conductivity and measure the impedance of concrete using LCR meter. By doing this, the electrical conductivity of each type of steel fiber reinforced cementitious composites (FRCC) is compared.

  • PDF

Test Application of Electrical Conductivity Measurement in Borehole for Determining Aquifer Properties (대수층의 수리특성 연구를 위한 시추공 전기전도도 측정기법의 현장 시험 적용)

  • Kim Yeong-Hwa;Kim Ji-Hoon;Hong Jeong-Pyo
    • The Journal of Engineering Geology
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • As a trial to find an efficient technique for determining hydraulic conductivity, a test application of electrical conductivity measurement technique was made using a signal conditioning data acquisition system in borehole. The experiment was made in two test boreholes BM-2 and BM-3 which are located in the Experiment forests of Kangwon National University in Bongmyongri, Chunchon. We obtained series of electric conductivity variation curves after the beginning and completion of saline water injection using these two bore-holes as the pumping well and the observing well alternatively, The analysis of time series electrical conductivity data suggests kinds of valuable information about aquifer properties by holes and depths, and we could confirm the potential of this method as an efficient tool for in situ aquifer test.

Measurement of the Thermal Conductivity of a Polycrystalline Diamond Thin Film via Light Source Thermal Analysis

  • Kim, Hojun;Kim, Daeyoon;Lee, Nagyeong;Lee, Yurim;Kim, Kwangbae;Song, Ohsung
    • Korean Journal of Materials Research
    • /
    • v.31 no.12
    • /
    • pp.665-671
    • /
    • 2021
  • A 1.8 ㎛ thick polycrystalline diamond (PCD) thin film layer is prepared on a Si(100) substrate using hot-filament chemical vapor deposition. Thereafter, its thermal conductivity is measured using the conventional laser flash analysis (LFA) method, a LaserPIT-M2 instrument, and the newly proposed light source thermal analysis (LSTA) method. The LSTA method measures the thermal conductivity of the prepared PCD thin film layer using an ultraviolet (UV) lamp with a wavelength of 395 nm as the heat source and a thermocouple installed at a specific distance. In addition, the microstructure and quality of the prepared PCD thin films are evaluated using an optical microscope, a field emission scanning electron microscope, and a micro-Raman spectroscope. The LFA, LaserPIT-M2, and LSTA determine the thermal conductivities of the PCD thin films, which are 1.7, 1430, and 213.43 W/(m·K), respectively, indicating that the LFA method and LaserPIT-M2 are prone to errors. Considering the grain size of PCD, we conclude that the LSTA method is the most reliable one for determining the thermal conductivity of the fabricated PCD thin film layers. Therefore, the proposed LSTA method presents significant potential for the accurate and reliable measurement of the thermal conductivity of PCD thin films.

Automatic Measurement of the Degree of Contamination with Electric Conductivity and Oscillating Frequency (발진주파수 및 전도도를 통한 오손도 자동측정)

  • 최남호;구경완;이명섭;한상옥;정재기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.153-156
    • /
    • 2000
  • To reduce the maintenance expense, and the possibility of electric outage and accident, we should optimize the outdoor insulation system. And for the optimization, accurate measurement for the degree of contamination with climatic conditions, such as wind, rain, and drought, should be carried. However the classical measuring method, brush wiping, has some problems in the aspect of man power, reliability, and expense. In this paper, we propose two type apparatus, which could detect the degree of contamination on insulators in outdoor insulation system, such as transmission and distribution line insulator and bushing. One use the leakage current, and the other use the oscillating frequency to check the degree of contamination. To avoid the oxidation of electrode AC source, and the low degree of contamination was applied. From the result of this investigation we could get the good relationship between the degree of contamination and the leakage current and oscillating frequency

  • PDF

Quantitative Method to Measure Thermal Conductivity of One-Dimensional Nanostructures Based on Scanning Thermal Wave Microscopy (주사탐침열파현미경을 이용한 1 차원 나노구조체의 정량적 열전도도 계측기법)

  • Park, Kyung Bae;Chung, Jae Hun;Hwang, Gwang Seok;Jung, Eui Han;Kwon, Oh Myoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.957-962
    • /
    • 2014
  • We present a method to quantitatively measure the thermal conductivity of one-dimensional nanostructures by utilizing scanning thermal wave microscopy (STWM) at a nanoscale spatial resolution. In this paper, we explain the principle for measuring the thermal diffusivity of one-dimensional nanostructures using STWM and the theoretical analysis procedure for quantifying the thermal diffusivity. The SWTM measurement method obtains the thermal conductivity by measuring the thermal diffusivity, which has only a phase lag relative to the distance corresponding to the transferred thermal wave. It is not affected by the thermal contact resistances between the heat source and nanostructure and between the nanostructure and probe. Thus, the heat flux applied to the nanostructure is accurately obtained. The proposed method provides a very simple and quantitative measurement relative to conventional measurement techniques.

Image Analysis and DC Conductivity Measurement for the Evaluation of Carbon Nanotube Distribution in Cement Matrix

  • Nam, I.W.;Lee, H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.4
    • /
    • pp.427-438
    • /
    • 2015
  • The present work proposes a new image analysis method for the evaluation of the multi-walled carbon nanotube (MWNT) distribution in a cement matrix. In this method, white cement was used instead of ordinary Portland cement with MWNT in an effort to differentiate MWNT from the cement matrix. In addition, MWNT-embedded cement composites were fabricated under different flows of fresh composite mixtures, incorporating a constant MWNT content (0.6 wt%) to verify correlation between the MWNT distribution and flow. The image analysis demonstrated that the MWNT distribution was significantly enhanced in the composites fabricated under a low flow condition, and DC conductivity results revealed the dramatic increase in the conductivity of the composites fabricated under the same condition, which supported the image analysis results. The composites were also prepared under the low flow condition (114 mm < flow < 126 mm), incorporating various MWNT contents. The image analysis of the composites revealed an increase in the planar occupation ratio of MWNT, and DC conductivity results exhibited dramatic increase in the conductivity (percolation phenomena) as the MWNT content increased. The image analysis and DC conductivity results indicated that fabrication of the composites under the low flow condition was an effective way to enhance the MWNT distribution.