• Title/Summary/Keyword: conditions of evaporation

Search Result 458, Processing Time 0.028 seconds

A Study on the Development of a Simulation Model for Predicting Soil Moisture Content and Scheduling Irrigation (토양수분함량 예측 및 계획관개 모의 모형 개발에 관한 연구(I))

  • 김철회;고재군
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.1
    • /
    • pp.4279-4295
    • /
    • 1977
  • Two types of model were established in order to product the soil moisture content by which information on irrigation could be obtained. Model-I was to represent the soil moisture depletion and was established based on the concept of water balance in a given soil profile. Model-II was a mathematical model derived from the analysis of soil moisture variation curves which were drawn from the observed data. In establishing the Model-I, the method and procedure to estimate parameters for the determination of the variables such as evapotranspirations, effective rainfalls, and drainage amounts were discussed. Empirical equations representing soil moisture variation curves were derived from the observed data as the Model-II. The procedure for forecasting timing and amounts of irrigation under the given soil moisture content was discussed. The established models were checked by comparing the observed data with those predicted by the model. Obtained results are summarized as follows: 1. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as the equation(2). 2. Among the various empirical formulae for potential evapotranspiration (Etp), Penman's formula was best fit to the data observed with the evaporation pans and tanks in Suweon area. High degree of positive correlation between Penman's predicted data and observed data with a large evaporation pan was confirmed. and the regression enquation was Y=0.7436X+17.2918, where Y represents evaporation rate from large evaporation pan, in mm/10days, and X represents potential evapotranspiration rate estimated by use of Penman's formula. 3. Evapotranspiration, Et, could be estimated from the potential evapotranspiration, Etp, by introducing the consumptive use coefficient, Kc, which was repre sensed by the following relationship: Kc=Kco$.$Ka+Ks‥‥‥(Eq. 6) where Kco : crop coefficient Ka : coefficient depending on the soil moisture content Ks : correction coefficient a. Crop coefficient. Kco. Crop coefficients of barley, bean, and wheat for each growth stage were found to be dependent on the crop. b. Coefficient depending on the soil moisture content, Ka. The values of Ka for clay loam, sandy loam, and loamy sand revealed a similar tendency to those of Pierce type. c. Correction coefficent, Ks. Following relationships were established to estimate Ks values: Ks=Kc-Kco$.$Ka, where Ks=0 if Kc,=Kco$.$K0$\geq$1.0, otherwise Ks=1-Kco$.$Ka 4. Effective rainfall, Re, was estimated by using following relationships : Re=D, if R-D$\geq$0, otherwise, Re=R 5. The difference between rainfall, R, and the soil moisture depletion D, was taken as drainage amount, Wd. {{{{D= SUM from { {i }=1} to n (Et-Re-I+Wd)}}}} if Wd=0, otherwise, {{{{D= SUM from { {i }=tf} to n (Et-Re-I+Wd)}}}} where tf=2∼3 days. 6. The curves and their corresponding empirical equations for the variation of soil moisture depending on the soil types, soil depths are shown on Fig. 8 (a,b.c,d). The general mathematical model on soil moisture variation depending on seasons, weather, and soil types were as follow: {{{{SMC= SUM ( { C}_{i }Exp( { - lambda }_{i } { t}_{i } )+ { Re}_{i } - { Excess}_{i } )}}}} where SMC : soil moisture content C : constant depending on an initial soil moisture content $\lambda$ : constant depending on season t : time Re : effective rainfall Excess : drainage and excess soil moisture other than drainage. The values of $\lambda$ are shown on Table 1. 7. The timing and amount of irrigation could be predicted by the equation (9-a) and (9-b,c), respectively. 8. Under the given conditions, the model for scheduling irrigation was completed. Fig. 9 show computer flow charts of the model. a. To estimate a potential evapotranspiration, Penman's equation was used if a complete observed meteorological data were available, and Jensen-Haise's equation was used if a forecasted meteorological data were available, However none of the observed or forecasted data were available, the equation (15) was used. b. As an input time data, a crop carlender was used, which was made based on the time when the growth stage of the crop shows it's maximum effective leaf coverage. 9. For the purpose of validation of the models, observed data of soil moiture content under various conditions from May, 1975 to July, 1975 were compared to the data predicted by Model-I and Model-II. Model-I shows the relative error of 4.6 to 14.3 percent which is an acceptable range of error in view of engineering purpose. Model-II shows 3 to 16.7 percent of relative error which is a little larger than the one from the Model-I. 10. Comparing two models, the followings are concluded: Model-I established on the theoretical background can predict with a satisfiable reliability far practical use provided that forecasted meteorological data are available. On the other hand, Model-II was superior to Model-I in it's simplicity, but it needs long period and wide scope of observed data to predict acceptable soil moisture content. Further studies are needed on the Model-II to make it acceptable in practical use.

  • PDF

An Experimental Study of Spray Nozzle Desalination Facility (담수화 설비 스프레이 노즐에 대한 실험적 연구)

  • SHIN HYUN-KYOUNG;JOO HYUN-TAE;PARK MIN-HO;PARK KYOUNG-MIN;KIM JIN-YOUNG;LIM JIN-YOUNG
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.1 s.68
    • /
    • pp.26-31
    • /
    • 2006
  • Experimental research was undertaken to develop a domestic spray nozzle used on equipment for desalination. First, we made a test set-up in order to confirm nozzle efficiency of spray and distribution under different pressure conditions. Then, we found a maximum spray condition after verifying reliability of this facility. An optimum arrangement of the nozzle, based on the test result, was made using CATIA V5 and EXCEL.

Hydrophobic Membrans of Tetrafluoroethylene and 2,2,4, Trifluoro 5 Trifluorometoxy 1,3 Dioxole

  • Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • Korean Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.50-58
    • /
    • 1999
  • Symmetric asymmetric and composite perfluoropolymer membranes made with HYFLON AD have been prepared and evaluated. Porous and non porous symmetric membranes have been prepared by solvent evaporation with various processing conditions. Non-contact atomic force microscopy (AFM) was used to investigate the membrane morphology in air. Analysis of the images gave quantitative imformation on the surface pore strcture in particular on the pore size distributin. Possible useful uses of porous membranes are envisaged in the field of gas-liquid separations such as membrane contactors (MSc) Molecular Dynamics(MD) simulations structure of HYFLON AD 60X copolymer supporting these results are also reported. Amorphous perfluoropolymer membranes appears to be ideal other than in MCs when separation processes have to be performed in hostile environments i.e. high temperatures and aggressive non-aqueous media such as chemicals and solvents. In these cases HYFLON AD mem-branes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

Fabrication of Pentacene Thin Film Transistors by using Organic Vapor Phase Deposition System (Organic Vapor Phase Deposition 방식을 이용한 펜타센 유기박막트랜지스터의 제작)

  • Jung Bo-Chul;Song Chung-Kun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • In this paper, we investigated the deposition of pentacene thin film on a large area substrate by Organic Vapor Phase Deposition(OVPD) and applied it to fabrication of Organic Thin Film Transistor(OTFT). We extracted the optimum deposition conditions such as evaporation temperature of $260^{\circ}C$, carrier gas flow rate of 10 sccm and chamber vacuum pressure of 0.1 torr. We fabricated 72 OTFTs on the 4 inch size Si Wafer, Which produced the average mobility of $0.1{\pm}0.021cm^2/V{\cdot}s$, average subthreshold slope of 1.04 dec/V, average threshold voltage of -6.55 V, and off-state current is $0.973pA/{\mu}m$. The overall performance of pentacene TFTs over 4 ' wafer exhibited the uniformity with the variation less than 20 %. This proves that OVPD is a suitable methode for the deposition of organic thin film over a large area substrate.

Low-Temperature Operating $SnO_2$ Nanowire $NO_2$ Sensor

  • Jung, Tae-Hwan;Kwon, Soon-Il;Kim, Yeon-Woo;Park, Jae-Hwan;Lim, Dong-Gun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.485-486
    • /
    • 2008
  • The network structure of $SnO_2$ nanowires was fabricated on the electrodes by a simple thermal evaporation process from Sn metal powders and oxygen gas. The diameter of the nanowires was $20\;{\sim}\;60\;nm$ depending on the processing conditions. The operating temperature of the sensor could be decreased down below $50^{\circ}C$ by controlling the properties of the nanowires and the structures of the electrodes. The sensitivities were $10\;{\sim}\;15$ when the $NO_2$ concentrations were $10\;{\sim}\;50\;ppm$ at the operating temperature of $50^{\circ}C$.

  • PDF

Performance Analysis of R744 (Carbon Dioxide) Transcritical Refrigeration System Using Internal Heat Exchanger (내부 열교환기를 이용한 R744용 초임계 냉동사이클의 성능 분석)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.459-465
    • /
    • 2009
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system. These internal heat exchangers(liquid-suction or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as gas cooler pressure and evaporation temperatures, superheat in the evaporator and temperature of gas cooler outlet, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R744, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative capacity index) of this system. With a thorough grasp of these effect, it is necessary to design the R744 compression refrigeration cycle using internal heat exchanger.

Characterization of Tribological Properties of DLC Films Prepared by Different Deposition Method (증착방법에 따른 DLC 막의 마찰-마모 특성평가)

  • Oh, Yoon-Suk
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.5
    • /
    • pp.497-504
    • /
    • 2009
  • DLC is considered as the candidate material for application of moving parts in automotive components relatively in high pressure and temperature operating conditions for its high hardness with self lubrication and chemical inertness. Different deposition method such as arc plating, ion gun plating and PECVD were used for comparing mechanical and tribological properties of each DLCs deposited on stainless steel with 1 um thick respectively. Among these 3 types of DLCs, the arc plated DLC film showed highest value for wear resistance in dry condition. From the results of analysis for physical properties of DLC films, it seems that the adhesion force and crack initiation modes were more important factors than intrinsic mechanical properties such as hardness, elastic modulus and/or roughness to the wear resistance of DLC films. Raman spectroscopy was used for understanding chemical bonding natures of each type of DLC films. Typical D and G peaks were identified based on the deposition method. Hardness of the coating layers were identified by nanoindentation method and the adhesions were checked by scratch method.

Preparation of Poly(lactic acid) Scaffolds by the Particulate Leaching (염 추출법에 의한 폴리락틱산 다공성 지지체 가공)

  • Lee, Ji-Hae;Lee, Jong-Rok;Kang, Ho-Jong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.324-331
    • /
    • 2003
  • Particulate leaching method for the preparation of porous PLLA scaffolds was carried out and especially, the effect of PLLA/$CHCl_3$ solution concentration on the salt leaching rate and the pore structure of PLLA scaffolds were considered. It was found that maintaining lower PLLA/$CHCl_3$ concentration and higher $CHCl_3$ evaporation temperature in the preparation of PLLA/NaCl mixtures resulted in the enhancement of salt leaching rat e and higher porosity. This is understood that those conditions could minimize the formation of dense PLLA layer on the surface of PLLA/NaCl mixture as well as introducing better porosity on the surface. Higher salt leaching temperature accelerated the salt leaching rate but it seems that there is no influence on the porosity of PLLA scaffolds.

Heat Transfer Characteristics of Heat Exchange Module for a Water Tube Type Modular Boiler (모듈형 수관식 보일러를 위한 열교환 모듈의 열전달 특성)

  • Ahn, Joon;Kim, Jong-Jin;Kang, Sae-Byul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • A finned tube type heat exchange module has been proposed for a multi-burner water tube boiler. Fin density and length increase in streamwise direction to equalize the evaporation for each module, which makes it difficult to apply conventional bulk design procedure. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also conducted to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, since the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.