• Title/Summary/Keyword: conditions of evaporation

Search Result 458, Processing Time 0.025 seconds

Deposition Properties of NiCr Thin Films Prepared by Thermal Evaporation (Thermal Evaporation법으로 제조한 NiCr 박막의 증착 특성)

  • Kun, Yong;Park, Yong-Ju;Choi, Seoung-Pyung;Jung, Jin;Choi, Gwang-Pyo;Ryu, Hyun-Wook;Park, Jin-Seong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.6
    • /
    • pp.450-455
    • /
    • 2004
  • NiCr thin films were fabricated by thermal evaporation method using NiCr alloy as evaporating source. NiCr thin films were annealed at various temperatures in air atmosphere in order to investigate effects of annealing conditions on phase change, composition, and microstructures of NiCr films. Typical multilayer was formed after annealing in air atmosphere. This results from the diffusion and oxidation of Cr toward surface during annealing. In the case of annealing at 700$^{\circ}C$, large columnar grains of NiO were formed on Cr-oxide layer through the diffusion and oxidation of Ni over Cr-oxide layer. Especially, NiO layer was formed additionally on surface, sustaining the underlayer structure with the formation of porous Ni layer.

Fractal Structures of Molybdena Thin Films Deposited on Alumina Ceramics

  • Zhang, Jizhgong;Diaoa, Zhu;Tiana, Haoyang
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.1
    • /
    • pp.36-39
    • /
    • 2002
  • Molybdena powder was heated at both 660$^{\circ}C$ and 700$^{\circ}C$ for half-hour in an evaporation-deposition device. The molybdena thin films deposited on the surfaces of alumina ceramics displayed two kinds of fractal aggregates, i.e., the stackings of ribbon-like crystals and ramified palm-like structures. It is revealed from the experimental results that the microstructures of these fractal aggregates depended strongly on their growth conditions. The dynamics of fractal growth of molybdena thin film is discussed.

  • PDF

Numerical Study on the Droplet Vaporization Characteristics of Dimethyl Ether(DME) Droplet (DME 액적의 증발특성 해석)

  • 유용욱;류종혁;김용모
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.69-75
    • /
    • 2004
  • The present study is numerically investigated for the high pressure effects on the vaporization process of the DME droplet. The evaporation rate of DME droplets is about twice that of dodecane droplets at the same chamber condition. The DM droplet vaporization characteristics is parametrically studied for the wide range of the operating conditions encountered with the high pressure combustion process.

A Study on the Zone Melting Recrystallization of Sequentially Evaporated InSb Thin Films for Improvement of the Electron Mobility (순차 증착한 InSb 박막의 전자 이동도 향상을 위한 대용융 재결정에 관한 연구)

  • 김병윤;현규택;주승기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.6
    • /
    • pp.31-37
    • /
    • 1993
  • InSb thin films were fabricated by zone melting recrystallization of In/Sb multilayered thin films prepared by sequential evaporation. Unreacted metal phase or dispersed metal precipitates lowered the electron mobility and the electron mobility increased with development of (111) prefered orientation. Properties of the film could be controlled by changing mzximum temperature and scanning speed, and the electron mobility as high as 12, 000 cm $^2$/Vsec could be obtained under the optimized conditions.

  • PDF

Characteristics of dry-process based metal nano ink for printed electrodes

  • Kim, Dong-Kwon;Lee, Caroline;Hong, Seong-Je;Kim, Young-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1466-1468
    • /
    • 2009
  • The preparation method of copper nanopowder by dry process for conductive ink was investigated. Inert gas condensation method was used to synthesize copper nanopowder. The produced powders was spherical and sized 10~100nm flowing the conditions. The results showed that input voltage and evaporation rate is critical variables for nano-sized copper powder.

  • PDF

Prediction of Adiabatic Capillary Tube Length of Heat Pump Using Carbon Dioxide (CO2 히트펌프용 단열 모세관 길이 예측에 관한 연구)

  • Oh, Hoo-Kyu;Choi, Kwang-Hwan;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.576-581
    • /
    • 2011
  • In this paper, the prediction of adiabatic capillary tube of heat pump using carbon dioxide is investigated theoretically and experimentally to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include evaporation temperature, cooling pressure of gas cooler, mass flowrate, and the length and diameter of capillary tube. Based on study results of several researchers, the correlation predicting the length of capillary tube of $CO_2$ heat pump was proposed. And the experimental results of evaporation temperature, mass flowrate and cooling pressure in adiabatic capillary tube have an good agreement to those calculated from Eq. (3) within 0.63~10.9%. Therefore, the prediction calculating the length of adiabatic capillary tube of $CO_2$ heat pump was proposed at the given conditions such as cooling pressure, evaporation temperature and capillary tube diameter.

Performance characteristics of the Coil Deposition Type Heat Pump using Geothermal Energy (지열을 이용한 코일 침적형 히트펌프의 성능 특성)

  • Oh, Hoo-Kyu;Lee, Dong-Gun;Jeon, Min-Ju;Son, Chang-Hyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.437-444
    • /
    • 2012
  • This paper describes the experimental characteristics on cooling and heating performance of the coil deposition type heat pump using geothermal energy to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling degree, evaporation and condensation temperature in the coil deposition type heat pump using geothermal energy. The main results are summarized as follows : As the evaporation temperature and subcooling degree of the coil deposition type heat pump using geothermal energy increases, and the condensation temperature decreases, the COP of this system increases. The subcooling degree, evaporation and condensation temperature of the coil deposition type heat pump have an effect on cooling and heating COP of this heat pump. Therefore, it is a necessary to determine the optimum operation conditions for the highest COP of this heat pump presented in this study.

Studies on the Evaporative Heat Transfer Characteristics and Pressure Drop of CO2 Flowing Upward in Inclined (45°) Smooth and Micro-fin Tubes (경사평활관 및 마이크로핀관에서의 이산화탄소의 증발열전달 특성과 압력강하에 관한 실험적 연구)

  • Kim, Yong-Jin;Cho, Jin-Min;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.612-620
    • /
    • 2008
  • New alternative refrigerants have been developed due to the ozone layer depletion and global warming. For this reason, carbon dioxide is believed to be a promising refrigerant for use in air conditioners and heat pumps. Evaporative heat transfer characteristics and pressure drop of $CO_2$ with outer diameter of 5 mm in inclined ($45^{\circ}$) smooth and micro-fin tubes have been investigated by the experiments with respect to several test conditions such as mass fluxes, heat fluxes, evaporation temperatures in this study. The inclined ($45^{\circ}$) smooth and micro-fin tubes with length of 1.44 m were installed to measure the evaporative heat transfer coefficients of $CO_2$ and heat was supplied to the refrigerant by direct heating method where the test tube was uniformly heated by electricity. The tests were conducted at mass fluxes from 212 to $656\;kg/m^2s$, heat fluxes from 15 to $60\;kW/m^2$ and evaporation temperatures from -10 to $20^{\circ}C$. The heat transfer coefficients of $CO_2$ are slightly increased with increasing mass flux, and the heat transfer characteristics in the inclined ($45^{\circ}$) tubes are enhanced about $5{\sim}10%$ compared with those in horizontal or vertical tubes.

Effect of Coagulating Conditions on the Morphology of Membrane and Drug Being Impregnated (응고화 경로가 고분자막 및 함침 약제 형상 변화에 미치는 영향의 분석)

  • 한명진;남석태;이재훈
    • Polymer(Korea)
    • /
    • v.25 no.2
    • /
    • pp.151-160
    • /
    • 2001
  • Polymeric membranes consisting of poly(d,1-lactide) as a polymer matrix and crystallizable progesterone as a drug were prepared by coagulating polymeric solutions. The homogeneous casting solutions in dimethyformamide were solidified by using three different coagulating processes : solvent evaporation under vacuum, solvent extraction via immersion into the nonsolvent bath, or vapor exposure at high humidity condition. With solvent removal via evaporation under vacuum, the cast solution film was vitrified to form a homogeneous film containing progesterone of spherical shape distributed evenly in the film. Being prepared by solvent extraction via immersion into a water bath, the resulting membrane showed an asymmetric structure, with progesterone of big crystallites distributed unevenly in the structure. On the other hand, the coagulation under high humidity transformed the cast film into a sponge-like structure, where progesterone took a shape like flake.

  • PDF

A Study on the Effect of Evaporation of Liquid Hydrogen Tank Related to Horizontal Sinewave (액화수소 저장탱크의 수평요동이 증발 특성에 미치는 영향에 대한 연구)

  • SEUNG JUN OH;JUN YEONG KWON;JEONG HWAN YOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.155-161
    • /
    • 2023
  • Recently, a study on alternative and renewable energy is being conducted due to energy depletion and environmental problems. In particular, a hydrogen has the advantage of converting and storing the remaining energy into water-electrolyzed hydrogen through renewable energy generation. In general, due to reasons such as insulation problems, a study on high-pressure hydrogen storage tanks and related parts has recently been conducted. However, in the case of liquid hydrogen, the volume can be reduced by about 800 times or more compared to high-pressure hydrogen gas, so the study on this is needed as a technology that can increase energy density. In this study, the evaporation characteristics were analyzed under fixed heat flux conditions for liquid hydrogen storage tanks and the change in thermal stratification according to sloshing was analyzed. The heat flux condition was fixed at 250 W/m2 and the horizontal resonance frequency of the primary mode was applied to the storage tank. As a result, it was confirmed that the thermal stratification phenomenon decreased compared to the case where the slashing was not present due to forced convection when the slashing was present.