• Title/Summary/Keyword: conditioning simulation

Search Result 999, Processing Time 0.022 seconds

Theoretical Analysis on Heat Transfer Characteristics and Heat Flux Performance in Ondol Systems of Dried Type (건식온돌시스템의 전열특성 및 방열성능에 관한 이론적 분석)

  • Jang, Yong-Sung;Yu, Ki-Hyung;Cho, Dong-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.176-181
    • /
    • 2007
  • This study aims to evaluate theoretically heat transfer characteristics and heat flux performance in ondol system of dried type is composed of panel of ceramics to improve of thermal conductivity and fin to expand heat. To this end, we analyzed effect of design factors(temperature of hot water, set temperature of room and thermal conductivity of finishing materials) in ondol system of dried type by heat transfer analysis. The main results of this study are summarized as follows; The deviation of heat flux and temperature was reduced by heat expansion from fin decreasing heat loss generated in air layer. The temperature and heat flux in upper finishing materials surface linearly increased according to temperature increment of hot water, but the temperature distribution in upper surface was assessed uneven. The greater heat resistance value of upper finishing materials, the deviation of maximum temperature and minimum temperature was decreased. Also, we suggested a basic design data about ondol system of dried type through an analysis of simulation results on heat transfer characteristics and heat flux performance.

  • PDF

An Analytical Study on the Optimal Set-point of the Hybrid Plant (복합열원설비 운전온도 최적 설정에 관한 해석적 연구)

  • Jeon, Jong-Ug;Lee, Sun-Il;Lee, Tae-Won;Kim, Yong-Ki;Hong, Dae-Hie;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.352-357
    • /
    • 2007
  • The objective of this study is to find the optimal set-point of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Ground Source Heat Pump) and the conventional plant(chiller, boiler). The work presented in this study was carried out by using the EnergyPlus(Version 2.0). In order to validate the simulation model, field data were measured from a building. The GSHP was used as a base plant and the conventional plant as the assistant plant. Various temperatures were controlled (zone summer set-point, zone winter set-point, chilled water temperature, hot water temperature) to find the optimal set-point temperature of the system. The influence of the various set-points were analyzed seasonally.

  • PDF

Numerical Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at each Operation Mode (동시냉난방 열펌프 시스템의 운전모드별 성능특성에 관한 수치적 연구)

  • Joo, Young-Ju;Jung, Hyun-Joon;Kang, Hoon;Choi, Jong-Min;Lee, Moo-Yeon;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.370-375
    • /
    • 2007
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this numerical study, a 4-room simultaneous heating and cooling heat pump system was modeled and its performance was calculated at each operating mode. Also, performance analysis was compared with experimental results.

  • PDF

Simulation of the effect of working fluids on the horizontal tube condenser (작동유체가 수평관형 응축기 성능에 미치는 영향에 관한 모사)

  • Jun, Yong-Du;Lee, Kum-Bae;O, Gyu-Nam;Kim, Jin-Kyong;Park, Ki-Ho;Chung, Dae-Hun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.281-285
    • /
    • 2008
  • Effective use of available energy sources is of general concern along with the issues of global warming and unstable oil price. As one of the effort to recover waste heat from industrial facilities effectively, researchers have interest in a technology called organic Rankine cycle(ORC), in which the working fluid is some organic liquid instead of water. Known to have poor efficiency already, this old technology is considered to give an innovative solution to utilizing low grade energy sources, by improving the efficiency. Nano fluidics, coatings and the use of additives are the examples of these efforts. In the present study, we present simulated performance of a horizontal tube type condenser geometry. N-hexanr and isopentane are compared to water vapor case under 1 atm and the inet cooling water temperature of $20^{\circ}C$. EES(Engineering Equations Solver) is used for the present work.

  • PDF

Impact Analysis of BIM Spread on Mechanical Design Process Based on Consciousness Survey among Japanese Mechanical Engineers

  • Hiyama, Kyosuke;Diao, Yunting;Kato, Shisuke;Koganei, Makoto
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2013
  • Recently, the demand for Building Information Modeling (BIM) construction drawings and specifications has increased rapidly. Many countries have also started to implement BIM. The BIM implementation can change the design flow of buildings including high-rise buildings. Against this background, many companies are focusing on the development of BIM software. BIM involves a three-dimensional CAD program that can examine the placement of ductwork and machinery. It significantly increases the efficiency of a mechanical design through data unification using standard Industry Foundation Classes (IFC). In addition, BIM functions as a database to simplify the use of simulation technology for designing air-conditioning systems. To further develop BIM, it is important to know the expectations of mechanical engineers who will become frequent users of BIM in the future. A survey was conducted among Japanese mechanical engineers using a questionnaire to analyze the expectations of mechanical design using BIM. The results show that many respondents strongly recognize BIM as a three-dimensional CAD program. However they also expect that BIM can help the optimization of their design works and enhance design functionality by running simulations utilizing BIM.

Optimal Windows Transmittance by Energy Performance Analysis and Subjective Evaluation in office building (에너지성능분석 및 감성평가에 의한 오피스 창호의 적정 투과율 선정)

  • Kim, Byoung-Soo;Kim, Jung-Shin;Yim, Oh-Yon
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.73-83
    • /
    • 2004
  • The purpose of this study is to select the optimal transmittance rate of windows in office buildings through subjective evaluation and energy performance analysis(computer simulation program ; DOE 2.1E). The results are as follows ; 1) In the subjective evaluation experiment, minimum transmittance of the glass is GE 30% and LT 70%, but the optimal transmittance rate is concluded in $40%\sim60%$. 2) As a result of the energy performance analysis, it is desirable for the building of consumptive with mainly air-conditioning to make transmittance as 40-60%. 3) Comparing foreign study on minimum and optimal transmittance rate is $25%\sim38%$, the minimum transmittance of this study is almost the same. But for the optimal transmittance rate, 20% more is needed for KOREAN.

A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator (직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법)

  • Jang, Hoon;Lee, Woo-Cheol;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant (국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션)

  • Kang, Dae Il;Kim, Kilyoo;Jang, Seung-Cheol;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.

A Three Phase Three-level PWM Switched Voltage Source Inverter with Zero Neutral Point Potential

  • Oh Won-Sik;Han Sang-Kyoo;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. It consists of three single-phase inverter modules. Each module is composed of a switched voltage source and inverter switches. The major advantage is that the peak value of the phase output voltage is twice as high as that of a conventional neutral-point-clamped (NPC) PWM inverter. Thus, the proposed inverter is suitable for applications with low voltage sources such as batteries, fuel cells, or solar cells. Furthermore, three-level waveforms of the proposed inverter can be achieved without the switch voltage imbalance problem. Since the average neutral point potential of the proposed inverter is zero, a common ground between the input stage and the output stage is possible. Therefore, it can be applied to a transformer-less Power Conditioning System (PCS). The proposed inverter is verified by a PSpice simulation and experimental results based on a laboratory prototype.

A Study on Development of High Efficiency PCS using in PEMFC Generation System (PEMFC 발전시스템용 고효율 PCS 개발에 관한 연구)

  • Kwak, Dong-Kurl;Jung, Won-Seok;Jung, Do-Young;Kim, Choon-Sam;Shim, Jae-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.266-268
    • /
    • 2009
  • In this paper, authors deal with a power conditioning system (PCS) of high efficiency for a proton exchange membrane fuel cell (PEMFC) generation system. Fuel cells are a direct current (DC) power generators. They generate electricity through an electrochemical process that converts the energy stored in a fuel directly into electricity. Fuel cells have many benefits, which produce no particulate matter, nitrogen or sulfur oxides. And they have few moving parts and produce little or no noise. When fueled by hydrogen, they yield only heat and water as byproducts. Their wide application can reduce our dependence on fossil fuels and foreign sources of petroleum. This paper studies on a novel PCS circuit topology of high efficiency using in PEMFC generation system The controlling switches in the PCS is operated to soft switching. Some digital simulation results and experimental results for the proposed PCS is confirmed to the validity of the analytical results.

  • PDF