Development and performance evaluation of the porous tube dilutor for real-time measurements of fine particles from high humidity environments (고수분 환경에서 미세먼지 실시간 측정을 위한 다공 튜브형 희석장치의 개발 및 성능 평가)

  • Woo, Chang Gyu;Hong, Ki-Jung;Kim, Hak-Joon;Kim, Yong-Jin;Han, Bangwoo;An, Jeongeun;Kang, Su Ji;Chun, Sung-Nam
    • Particle and aerosol research
    • /
    • v.13 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Real-time measurements of fine particles from stack emission gases are necessary due to the needs of continuous environmental monitoring of PM10 and PM2.5. The porous tube dilutor using hot and cold dilutions was developed to measure fine particles without condensable particles from highly humid emission gases and compared to the commercialized ejector-type dilutor. Particle size distributions were measured at the emission gases from a diesel engine and a coal-fired boiler. The porous tube dilutor could successfully measure the accumulation mode particles including relatively large particles more than $3{\mu}m$ without nuclei particles, while the ejector dilutor detected some condensable particles and could not detect large particles. The porous tube dilutor could successfully remove the already condensed water droplet particles generated by a humidifier in a $30m^3$ chamber.

A Study on the Permeation Properties of Permanent Gases and condensable Vapors through Hexamethyldisiloxane Plasma-Polymerized Membranes (Hexamethyldisiloxane 플라즈마 중합막을 통한 영구기체 및 응축성 증기의 투과특성에 관한 연구)

  • Oh, Sae-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.699-706
    • /
    • 2018
  • The permeation properties of plasma polymer membranes were studied for permanent gases such as He, $H_2$, $O_2$, $N_2$, $CH_4$ and condensable vapors such as $CO_2$, $C_2H_4$, $C_3H_8$. The plasma polymers were prepared by the discharge of microwave or radiofrequency(RF) wave. Hexamethyldisiloxane (HMDS) vapor was used as a monomer for plasma polymerization. In HMDS plasma-polymerized membranes prepared under microwave discharge, the permeability coefficient was dependent of the kinetic molecular diameter of the permeate gases. Additionally the membranes showed higher $O_2/N_2$ permselectivity compared to the plasma polymers from radiofrequency discharge. On the contrary, in the HMDS plasma-polymerized membranes prepared under radiofrequency discharge, the permeability coefficient was dependent of the critical temperature of the permeant gases. The membranes showed high selectivities of $C_2H_4$ and $C_3H_8$ over $N_2$. The permeability coefficient of plasma polymerized membranes prepared under microwave discharge was dependent of the molecular diameter of permeant gases because of high crosslinking density of the membrane. However, the crosslinking density of the plasma polymerized membranes prepared under RF discharge was lower because the energy density of RF wave is weaker than that of microwave. Hence, the permeability of RF plasma polymerized membranes became dependent of the critical temperature rather than molecular diameter of the gases.

A Study on the Dielectric Characteristics of Insulation Gases for a Sub-cooled Liquid Nitrogen System (이용률을 이용한 과냉질소 냉각시스템용 절연가스의 절연특성에 관한 연구)

  • Kang, Hyoung-Ku;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.1
    • /
    • pp.52-55
    • /
    • 2010
  • A sub-cooled liquid nitrogen system is known as a promising method to develop high voltage superconducting apparatuses such as superconducting fault current limiters (SFCLs) and superconducting cables. To develop a high voltage superconducting machine adopting the sub-cooled liquid nitrogen system with a constant pressure. injecting a non-condensable gas is indispensable. In this study. the dielectric characteristics of insulation gases are investigated and analyzed by using electric utilization factors ($\xi$). It is found that the maximum electric field at sparkover that occurs with 50 % probability. $E_{MAX.50%}$ exponentially decreases as the S increases. This means that the $E_{MAX.50%}$ at sparkover can be estimated with the $E_{MAX.50%}$

Vaporization and condensation of metallic species in hazardous waste incineration (폐기물 소각시 생성되는 유해 중금속물질의 증발.응축현상에 대한 연구)

  • Song, Yu-Seok;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1983-1993
    • /
    • 1996
  • For selected (pure and compound) metallic species effects of saturation ratio, temperature, particle size and number density on condensation mechanisms are first reviewed. The tendencies for vaporization and condensation differ between metallic species because of the significant differences in their saturation pressures. Then particle pressure of a metal vapor species at incineration temperature is calculated by simplifying waste as a compound of methane, chlorine and small amounts of metals and assuming a thermodynamic equilibrium state. Next the condition is assessed for which supersaturation of combustion gases by the species above the critical level for homogeneous condensation may occur, when the gases contain a large number of pre-existing particles such as entrained ashes. Regardless of the presence of chlorine in the waste, the homogeneous condensation of PbO vapors may occur, depending on number density of the pre-existing particles. However, when chlorine exists in the waste, the homogeneous condensation of PbCl$_2$vapors does not occur, which is similar to the case of Cd and Hg vapors. Thus these highly volatile species, PbCl$_2$, Cd, and Hg, may emit to atmosphere as vapor phase. In general, for reducing the emission of hazardous metallic species into the atmosphere, the number density of pre-existing particles has to be increased. For fixed particle number density, the temperature drop rate must be kept in low if the temperature at which a condensable vapor species emits from a incineration system is fixed, while the temperature drop rate must be kept in high if the residence time for which a condensable species stays in the system is fixed.

A Study on the Characteristics of Condensable Fine Particles in Flue Gas (배출가스 중 응축성미세먼지 특성 연구)

  • Gong, Buju;Kim, Jonghyeon;Kim, Hyeri;Lee, Sangbo;Kim, Hyungchun;Jo, Jeonghwa;Kim, Jeonghun;Gang, Daeil;Park, Jeong Min;Hong, Jihyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.5
    • /
    • pp.501-512
    • /
    • 2016
  • The study evaluated methods to measure condensable fine particles in flue gases and measured particulate matter by fuel and material to get precise concentrations and quantities. As a result of the method evaluation, it is required to improve test methods for measuring Condensable Particulate Matter (CPM) emitted after the conventional Filterable Particulate Matter (FPM) measurement process. Relative Standard Deviation (RSD) based on the evaluated analysis process showed that RSD percentages of FPM and CPM were around 27.0~139.5%. As errors in the process of CPM measurement and analysis can be caused while separating and dehydrating organic and inorganic materials from condensed liquid samples, transporting samples, and titrating ammonium hydroxide in the sample, it is required to comply with the exact test procedures. As for characteristics of FPM and CPM concentrations, CPM had about 1.6~63 times higher concentrations than FPM, and CPM caused huge increase in PM mass concentrations. Also, emission concentrations and quantities varied according to the characteristics of each fuel, the size of emitting facilities, operational conditions of emitters, etc. PM in the flue gases mostly consisted of CPM (61~99%), and the result of organic/inorganic component analysis revealed that organic dusts accounted for 30~88%. High-efficiency prevention facilities also had high concentrations of CPM due to large amounts of $NO_x$, and the more fuels, the more inorganic dusts. As a result of comparison between emission coefficients by fuel and the EPA AP-42, FPM had lower result values compared to that in the US materials, and CPM had higher values than FPM. For the emission coefficients of the total PM (FPM+CPM) by industry, that of thermal power stations (bituminous coal) was 71.64 g/ton, and cement manufacturing facility (blended fuels) 18.90 g/ton. In order to estimate emission quantities and coefficients proper to the circumstances of air pollutant-emitting facilities in Korea, measurement data need to be calculated in stages by facility condition according to the CPM measurement method in the study. About 80% of PM in flue gases are CPM, and a half of which are organic dusts that are mostly unknown yet. For effective management and control of PM in flue gases, it is necessary to identify the current conditions through quantitative and qualitative analysis of harmful organic substances, and have more interest in and conduct studies on unknown materials' measurements and behaviors.

Numerical simulation of air discharged in subcooled water pool

  • Y. Cordova ;D. Blanco ;Y. Rivera;C. Berna ;J.L. Munoz-Cobo ;A. Escriva
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3754-3767
    • /
    • 2023
  • Turbulent jet discharges in subcooled water pools are essential for safety systems in nuclear power plants, specifically in the pressure suppression pool of boiling water reactors and In-containment Refueling Water Storage Tank of advanced pressurized water reactors. The gas and liquid flow in these systems is investigated using multiphase flow analysis. This field has been extensively examined using a combination of experiments, theoretical models, and Computational Fluid Dynamics (CFD) simulations. ANSYS CFX offers two approaches to model multiphase flow behavior. The non-homogeneous Eulerian-Eulerian Model has been used in this work; it computes global information and is more convenient to study interpenetrated fluids. This study utilized the Large Eddy Simulation Model as the turbulence model, as it is better suited for non-stationary and buoyant flows. The CFD results of this study were validated with experimental data and theoretical results previously obtained. The figures of merit dimensionless penetration length and the dimensionless buoyancy length show good agreement with the experimental measurements. Correlations for these variables were obtained as a function of dimensionless numbers to give generality using only initial boundary conditions. CFD numerical model developed in this research has the capability to simulate the behavior of non-condensable gases discharged in water.

Permeation Behavior of Olefin/Nitrogen Gases through Siloxane based Polymeric Membranes (실록산계 고분자 막을 통한 올레핀/질소 기체 투과 거동)

  • 이수복;신효진;최승학;김정훈;박인준;노재성;강득주
    • Membrane Journal
    • /
    • v.13 no.4
    • /
    • pp.246-256
    • /
    • 2003
  • For the olefin recovery from polyolefin off-gas, the permeation behaviors of olefins and nitrogen were investigated through three kinds of PDMS membranes - cross-linked PDMS membranes, a polysiloxaneimide membrane, and oligo-PDMS modified PDMS membranes. Their pure gas permeabilities were measured as a function of operation temperature(-20 to $50^{\circ}C$) and pressure(1 to 25 atm) with ethylene($C_2\;H_4$), propylene($C_3\;H_6$), butylene($C_4\;H_8$), and nitrogen($N_2$) gases. The permeabilities of olefins and nitrogen highly depended upon the nature of PDMS membranes. Among these membranes, cross-linked PDMS membranes showed stable and high olefin/nitrogen selectivities over a wide operation pressure range and further study in various test conditions. Their permeability of olefin and nitrogen were governed by the condensation temperature(solubility selectivity) and plasticization, not the order of the size(diffusivity selectivity) of gases, which matched well with the general permeation behavior of rubbery polymeric membranes for condensable and non-condensable gases. With increasing feed pressure or decreasing feed temperature, the permeabilities of more condensible olefins increase highly, presumably due to high solubility and plasticization, but that of non-condensible nitrogen decreases slightly and thus, the selectivities of olefin/nitrogen increase highly.

Decomposition of primary tar influenced by char particle types and reaction time during biomass gasification (바이오매스 가스화시 촤 입자 종류 및 반응시간에 따른 일차타르의 분해 특성)

  • Park, Jinje;Lee, Yongwoon;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.33-36
    • /
    • 2014
  • Gasification of biomass produces syngas containing CO, $H_2$ and/or $CH_4$, which can then be converted into energy or value-added fuels. One of key issues for efficient gasification is to minimize tar concentration in the syngas for use in a final conversion device such as gas engine. This study investigated the decomposition of primary tar by catalytic cracking using char as catalyst, of which the feature can be integrated into a fixed bed gasifier design. The pyrolysis vapor containing tar from pyrolysis of wood at $500^{\circ}C$ was passed through a reactor filled with or without char at $800^{\circ}C$ for a residence time of 1, 3 or 5 sec. Then, the condensable vapor (water and tar) and gases were analyzed for the yields and elemental composition. Four types of char particles with different microscopic surface area and pore size distribution: wood, paddy straw, palm kernel shell and activated carbon. The results were analyzed for the mass and carbon yields of tar and the composition of product gases to conclude the effects of char types and residence time.

  • PDF

Performance Test for the Performance Reliability of the Heat Pipe for Cooling Power Semiconductors (전력반도체 냉각용 히트파이프의 성능안정성 파악을 위한 성능시험)

  • 강환국
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.203-212
    • /
    • 2004
  • The heat pipe for cooling power semiconductor is required no performance changing during the life cycle up to 20 years. For the long reliable performance of the heat pipe, my reasons that has possibility to generate non condensable gases we not allowed. In this research, the maximum heat transport rate and operation characteristics that are related to various geometric and thermal conditions are carried out. Also the test items, specifications and methods to guarantee the long life cycle of the heat pipe for power semiconductor cooling device are provided and the tests are performed.

Properties of Products from Slow Pyrolysis of Geodae-Uksae 1 (거대억새의 저속 열분해 생성물 특성 분석)

  • Lee, Yongwoon;Eum, Pu-Reun-Byul;Jung, Jinho;Hyun, Seunghun;Park, Yong-Kwon;Ryu, Changkook
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.235-237
    • /
    • 2012
  • Geodae-Uksae 1 is a variety of Miscanthus sacchariflorus recently discovered in Korea. It is being mass-cultivated for use as energy crop due to its superior productivity, as high as 30 ton/ha/yr for the dry mass. This study investigates the method of producing biochar and bio-oil from the crop using slow pyrolysis. Especially, the study focused on assessing the biochar properties for its application to soil to improve soil quality and sequestrate carbon. Using an electrically heated packed bed reactor, the products of slow pyrolysis from Geodae-Uksae 1 were produced over a temperature range of $300-700^{\circ}C$ with a heating rate of $10^{\circ}C/min$. The biochar, condensable vapor (bio-oil) and residual gases were characterized for the physical and chemical properties. It was concluded that the ideal temperature for pyrolysis to produce biochar is $500^{\circ}C$.

  • PDF