• 제목/요약/키워드: concrete-filled steel tube

검색결과 447건 처리시간 0.021초

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF

Stress-transfer in concrete encased and filled tube square columns employed in top-down construction

  • Kim, Sun-Hee;Yom, Kyong-Soo;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.63-77
    • /
    • 2016
  • Top-down construction is a construction technique in which pit excavation and structure construction are conducted simultaneously. Reducing construction time and minimizing noise and vibration which affect neighboring structures, the technique is widely employed in constructing downtown structures. While H-steel columns have been commonly used as core columns, concrete filled steel tube (CFT) columns are at the center of attention because the latter have less axial directionality and greater cross-sectional efficiency than the former. When compared with circular CFT columns, square CFT columns are more easily connected to the floor structure and the area of percussion rotary drilling (PRD) is smaller. For this reason, square CFT columns are used as core columns of concrete encased and filled square (CET) columns in underground floors. However, studies on the structural behavior and concrete stress transfer of CET columns have not been conducted. Since concrete is cast according to construction sequence, checking the stress of concrete inside the core columns and the stress of covering concrete is essential. This paper presents the results of structural tests and analyses conducted to evaluate the usability and safety of CET columns in top-down construction where CFT columns are used as core columns. Parameters in the tests are loading condition, concrete strength and covering depth. The compressive load capacity and failure behavior of specimens are evaluated. In addition, 2 cases of field application of CET columns in underground floors are analyzed.

콘크리트 충전 강관 부재의 휨거동에 관한 유한요소해석 (Finite Element Analysis of the Flexural Behavior of Concrete Filled Steel Tubes)

  • 강재윤;최은석;진원종;이정우;김병석;이흥수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.418-421
    • /
    • 2006
  • Appropriate analysis models for concrete-filled steel tube (CFT) subjected to bending moment were determined to assess flexural behavior of CFT member. Applying this model, finite element analyses was performed and compared against experimental data considering the compressive strength of in-filling material and the composite action between tube shell and in-filling core. Analysis results showed that the FE model proposed in this study is feasible for the analytical investigation of the flexural behavior of CFT member according to loading conditions, effect of compressive strength of various core materials and other design parameters.

  • PDF

콘크리트 충전 강관 거더-바닥판 합성단면의 휨거동에 관한 실험적 연구 (Experimental Study on Flexural Behavior of CFT Girder-Deck Composite Section)

  • 진원종;강재윤;최은석;이정우;이흥수;곽종원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.166-169
    • /
    • 2006
  • A new bridge system described in this paper uses concrete-filled steel tube (CFT) girders as a replacement for conventional girders. Experimental investigations were carried out to comprehend the flexural behavior of CFT girder-slab deck composite section. The experimental investigation consisted of designing and constructing a test specimen and loading it to collapse in bending to check the applicability of the system. The test results showed that concrete filled steel tube girders have good ductility and maintain its strength up to the end of the loading. In the test, the flexural behavior of each specimen of CFT girder-deck composite section is identified.

  • PDF

The behavior of concrete filled steel tubular columns infilled with high-strength geopolymer recycled aggregate concrete

  • Rajai Z. Al-Rousan;Haneen M. Sawalha
    • Steel and Composite Structures
    • /
    • 제51권6호
    • /
    • pp.661-678
    • /
    • 2024
  • The utilization of geopolymer recycled aggregate concrete (GRAC) as the infilled core of the concrete-filled steel tubular (CFST) columns provides superior economic and environmental benefits. However, limited research exists within the field of geopolymer recycled aggregate concrete considered a green and sustainable material, in addition to the limitation of the design guidelines to predict the behavior of such an innovative new material combination. Moreover, the behavior of high-strength concrete is different from the normal-strength one, especially when there is another material of high-strength properties, such as the steel tube. This paper aims to investigate the behavior of the axially loaded square high-strength GRACFST columns through the nonlinear finite element analysis (NLFEA). A total of thirty-two specimens were simulated using ABAQUS/Standard software with three main variables: recycled aggregate replacement ratio (0, 30, and 50) %, width-to-thickness ratios (52.0, 32.0, 23.4, and 18.7), and length-to-width ratio (3, 5, 9, and 12). During the analysis, the response in terms of the axial load versus the longitudinal strain was recorded and plotted. In addition, various mechanical properties were calculated and analyzed. In view of the results, it has been demonstrated that the mechanical properties of high-strength GRACFST columns such as ultimate load-bearing capacity, compressive stiffness, energy absorption capacity, and ductility increase with the increase of the steel tube thickness owing to the improvement of the confinement effect of the steel tube. In contrast, the incorporation of the recycled aggregate adversely affected the mentioned properties except the ductility, while the increase of the recycled aggregate replacement ratio improved the column's ductility. Moreover, it has been found that the increase in the length-to-width ratio significantly reduced both the failure strain and the energy absorption capacity. Finally, the obtained NLFEA results of the ultimate load-bearing capacity were compared with the corresponding predicted capacities by numerous codes. It has been concluded that AISC, ACI, and EC give conservative predictions for the ultimate load-bearing capacity since the confinement effect was not considered by these codes.

축력이 재하된 원형 콘크리트 충전강관 기둥의 최대 저항능력 (Ultimate Resisting Capacity of Axially Loaded Circular Concrete-Filled Steel Tube Columns)

  • 곽효경;곽지현
    • 콘크리트학회논문집
    • /
    • 제24권4호
    • /
    • pp.423-433
    • /
    • 2012
  • 콘크리트 충전 강관 기둥은 축하중 재하시 콘크리트에 구속응력이 발생함에 따라 콘크리트의 강도가 증가한다. 콘크리트의 강도 증가분은 발생된 구속응력의 크기에 종속되므로 비선형 해석을 통하여 원형 콘크리트 충전 강관의 축방향 하중에 대한 최대 저항능력을 산정하였다. 콘크리트의 포아송비 및 응력-변형률 관계와 같은 비선형 재료 특성을 고려하였으며, 강관의 다축 항복조건을 기준으로 최대 구속응력을 산정하였다. 실험 결과와의 비교를 통하여 제안된 모델을 검증하였으며, 회귀분석을 통하여 D/t 비율 및 재료성질에 따른 최대 구속응력 산정법을 단순화하였다. Eurocode 4 설계 기준 및 기존에 제안된 다양한 경험식과의 비교를 통하여 제안된 회귀분석식의 타당성을 검증하였다.

비재하 가열실험을 통한 이중강관 CFT기둥의 잔존강도 평가연구 (A Study on the Evaluation of Residual Strength of Double Concrete Filled Tube Column by Unstressed test)

  • 김선희;원용안;최성모
    • 한국강구조학회 논문집
    • /
    • 제24권1호
    • /
    • pp.81-89
    • /
    • 2012
  • 콘크리트 충전강관 기둥은 내부의 콘크리트에 의해 축열효과로 인해 철골기둥에 비해 내화성능이 우수하며, 기둥 단면 내 철근 및 강관을 보강하여 구조적내력 및 내화성능 향상연구가 이루어져 오고 있다. 실제로 보강된 CFT기둥은 고축력을 요구하는 기둥부재로 사용 빈도 수가 증가되고 있는 추세이다. 이러한 상황에서 CFT기둥을 사용한 건축물에 화재가 발생하여 손상을 입게 되었을 경우 성능 저하정도를 정밀하게 측정할 수 있는 기법이 필요하다. 본 연구에서는 화재 발생시 CFT기둥에 대한 내부 온도 분포를 평가 하고, 단면내부의 온도분포에 따라 내부 충전콘크리트와 보강재의 내력 저하 정도를 파악하여 CFT기둥의 전체적인 잔존강도를 평가하고자 한다.

중공형 콘크리트 충전 FRP Tube 말뚝의 휨강도 산정 (An Evaluation of Flexural Strength of Hollow Concrete Filled FRP Tube Piles)

  • 김형준;정흥진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.204-211
    • /
    • 2022
  • 본 연구에서는 복합말뚝의 장점을 활용하고 CFT말뚝의 단점인 부식에 대한 문제점을 해결할 수 있는 모델로 중공형 콘크리트 충전 FRP Tube 말뚝(Hollow Concrete Filled FRP Tube Pile, HCFFT말뚝)을 제시하였고, 수치해석 모델을 개발하여 거동을 분석하였다. 콘크리트가 손상 소성 거동, 강재가 항복 소성 거동, FRP가 탄성 거동을 한다는 것을 고려하여 변형률적합법을 적용하고, 중립축으로부터의 거리에 따른 FRP Tube 단면의 변화를 고려하여 HCFFT말뚝의 휨 강도 산정식을 제안하였다. 휨 강도 산정식과 수치해석 결과, 실험결과를 비교 분석하여 적정성을 검증하였다. 본 연구 결과는 FRP를 이용한 다양한 HCFFT말뚝의 최적설계에 기초자료로서 활용될 수 있을 것으로 판단된다.

Numerical simulation and analytical assessment of STCC columns filled with UHPC and UHPFRC

  • Nguyen, Chau V.;Le, An H.;Thai, Duc-Kien
    • Structural Engineering and Mechanics
    • /
    • 제70권1호
    • /
    • pp.13-31
    • /
    • 2019
  • A nonlinear finite element model (FEM) using ATENA-3D software to simulate the axially compressive behavior of circular steel tube confined concrete (CSTCC) columns infilled with ultra high performance concrete (UHPC) was presented in this paper. Some modifications to the material type "CC3DNonlinCementitious2User" of UHPC without and with the incorporation of steel fibers (UHPFRC) in compression and tension were adopted in FEM. The predictions of utimate strength and axial load versus axial strain curves obtained from FEM were in a good agreement with the test results of eighteen tested columns. Based on the results of FEM, the load distribution on the steel tube and the concrete core was derived for each modeled column. Furthermore, the effect of bonding between the steel tube and the concrete core was clarified by the change of friction coefficient in the material type "CC3DInterface" in FEM. The numerical results revealed that the increase in the friction coefficient leads to a greater contribution from the steel tube, a decrease in the ultimate load and an increase in the magnitude of the loss of load capacity. By comparing the results of FEM with experimental results, the appropriate friction coefficient between the steel tube and the concrete core was defined as 0.3 to 0.6. In addition to the numerical evaluation, eighteen analytical models for confined concrete in the literature were used to predict the peak confined strength to assess their suitability. To cope with CSTCC stub and intermediate columns, the equations for estimating the lateral confining stress and the equations for considering the slenderness in the selected models were proposed. It was found that all selected models except for EC2 (2004) gave a very good prediction. Among them, the model of Bing et al. (2001) was the best predictor.

복합말뚝용 중공형 콘크리트 충전 강관말뚝의 강도 특성 (Strength Characteristics of Hollow Prestressed Concrete Filled Steel Tube Piles for Hybrid Composite Piles)

  • 백규호
    • 한국지반공학회논문집
    • /
    • 제34권1호
    • /
    • pp.37-46
    • /
    • 2018
  • 얇은 두께의 강관 내부에 PHC말뚝을 합성해서 기존 PHC말뚝 및 강관말뚝보다 휨강도와 전단강도가 향상된 프리스트레스를 도입한 중공형 콘크리트 충전 강관(HCFT)말뚝을 개발하였다. HCFT말뚝의 강도특성을 조사하기 위해 다양한 조건에서 제작된 HCFT말뚝과 함께 동일 직경의 PHC말뚝 및 강관말뚝에 대해 휨강도 및 전단강도시험을 실시하였다. 시험결과 직경이 450~500mm인 HCFT말뚝은 동일 직경의 ICP말뚝 대비 2.88배, 두께 12mm의 강관말뚝 대비 1.19배의 휨강도를 발휘하였고, 강관말뚝의 2.40배에 달하는 전단강도를 발휘하였다. 그리고 HCFT말뚝의 강관 내벽에 설치한 전단연결재는 HCFT말뚝의 휨거동에 거의 영향을 주지 않았으며, HCFT말뚝의 휨강도는 HCFT말뚝을 구성하는 강관과 PHC말뚝에 대한 개별 휨강도 합산치보다 35~63% 컸는데 이것은 강관의 구속효과로 인해 압축영역에 있는 콘크리트의 강도가 증가하기 때문으로 판단된다. 또한 HCFT말뚝이 복합말뚝에서 상부말뚝으로 사용되면 수평하중을 받는 구조물의 수평변위 저감과 구조안정성 향상에 효과적일 것으로 사료된다.