• 제목/요약/키워드: concrete-filled steel tube

검색결과 446건 처리시간 0.042초

Structural Design of Mid-Story Isolated High-Rise Building - Roppongi Grand Tower

  • Nakamizo, Daiki;Koitabashi, Yuichi
    • 국제초고층학회논문집
    • /
    • 제7권3호
    • /
    • pp.233-242
    • /
    • 2018
  • Since the response reduction effect on over 200-meter-tall resulting from the seismic isolation system is smaller in general than low-rise and mid-rise buildings, mid-story isolated buildings are considered to reduce the response in the upper part above the isolation story, however, in many cases, the acceleration response just below the isolation story is likely to be the largest. This paper presents the structural design schemes, the design of the main structural frames, and the constructions of a 230-meter-tall super high-rise building with mid-story isolation mechanism integrated in Roppongi, Tokyo. Moreover, this paper shows how the architectural and structural design for integrating a mid-story isolation system in a super high-rise building has been conducted and what solutions have been derived in this project. The realization of this building indicates new possibilities for mid-story isolation design for super high-rise buildings.

콘크리트충전(充塡) 각형강관(角形鋼管) 기둥과 H형강 보 접합부(接合部)의 비선형 유한요소해석 (A Nonlinear FEM Analysis of Connections Between Concrete Filled Steel Tube Columns and H-Beams)

  • 윤현도;김용철;김옥룡;이훈희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권2호
    • /
    • pp.209-218
    • /
    • 2003
  • The analytical studies included nonlinear finite element analysis of split-tee connection details subjected to axial load and lateral load. A three-dimensional model of the connections between CFT columns and H-beams has been developed. Both initial geometrical imperfections and residual stresses are taken into consideration. A geometrically nonlinear load-displacement analysis of the structure containing the imperfection is then performed, using the Riks method. Analytical results are compared with existing experimental results. Extensive parametric analyses are carried out to investigate the relation of the connections between CFT columns and H-beam to various parameters such as the axial load, column width-thickness ratio, and split-tee thickness.

4차산업혁명 건설 및 기계 융합기술기반 CFT 중심축 구조체의 회전형 모듈러주택 (4th Industrial Revolution Construction and Machinery Covergence Technology base Rotational Modular Housing of CFT Central Axis Structure)

  • 김대건;우종열;우아진;전호경;홍영주;이동운
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.179-180
    • /
    • 2018
  • This study aims to provide a more comfortable environment for the external environment by designing a rotable dwelling that deviates from the conventional fixed residential concept. The round pillars, which are the center of the building, are constructed by placing the CFT (concrete Filled steel Tube) technique in place and assembling modular houses with columns. This study combines existing building techniques. Korea also needs to develop various related studies quickly.

  • PDF

사각판 스티프너로 보강한 콘크리트 충전강관 기둥과 H형강 보 접합부의 내진성능 (Seismic Performance of Wide Flange Beam-to-Concrete Filled Tube Column Joints with Stiffening Plates around the Column)

  • 박종원;강승민;김욱종
    • 한국강구조학회 논문집
    • /
    • 제15권2호
    • /
    • pp.167-174
    • /
    • 2003
  • 본 연구는 보 플랜지와 스티프너의 용접부 양단, 기둥 모서리 부분 스티프너에 라운드를 두는 방법 등을 통하여 총 7개 시험체에 실물대 반복하중실험을 실시한 결과를 나타낸 것이다. 실험 결과를 통하여 다음과 같은 결론을 얻을 수 있었다. (1) 필레(fillet)를 둠으로써 응력집중을 줄여 내진성능을 크게 향상 시킬 수 있다. (2) 스티프너 폭의 증가로 접합부의 강성 및 강도는 증가하였지만 에너지 소산 능력은 감소하였다. (3) 모든 시험체는 규준에서 강진지역의 내진구조에 대해 요구하는 총 0.04 radian의 회전각을 발휘할 수 있는 것으로 나타났다.

Finite element study the seismic behavior of connection to replace the continuity plates in (NFT/CFT) steel columns

  • Rezaifar, Omid;Younesi, Adel
    • Steel and Composite Structures
    • /
    • 제21권1호
    • /
    • pp.73-91
    • /
    • 2016
  • The use of box columns has been increased due to the rigidity in rigid orthogonal moment resisting frames. On the other hand, the installation and welding of necessary horizontal continuity plates inside the columns are both labor-consuming and costly tasks. Accordingly, in this paper, a new beam-to-box column connection by trapezoidal external stiffeners and horizontal bar mats is presented to provide seismic parameters. The proposed connection consists of eight external stiffeners in the level of beam flanges and five horizontal bar mats in Concrete Filled Tube (CFT) columns. The new connection effectively alleviates the stress concentration and moves the plastic hinge away from the column face by horizontal external stiffeners. In addition, the result shows that proposed connection has provided the required strength and rigidity of connection, so that the increased strength, 8.08% and rigidity, 3.01% are compared to connection with internal continuity plates, also the results indicate that this connection can offer appropriate ductility and energy dissipation capacity for its potential application in moment resisting frames in seismic region. As a result, the proposed connection can be a good alternative for connection with continuity plates.

Experimental and FE investigation of repairing deficient square CFST beams using FRP

  • Mustafa, Suzan A.A.
    • Steel and Composite Structures
    • /
    • 제29권2호
    • /
    • pp.187-200
    • /
    • 2018
  • This paper handles the repairing of deficient square Concrete-Filled Steel-Tube (CFST) beams subject to bending through an experimental and numerical program. Eight square-CFST beams were tested. A 5-mm artificial notch was induced at mid-span of seven beams, four of them were repaired by using CFRP sheets and two were repaired by using GFRP sheets. The beam deflection, strain and ultimate moments were recorded. It was found that providing different cut-off points for the different layers of FRP sheets prohibited failure at termination points due to stress concentrations. Using different lengths of FRP sheets around the notch retarded crack propagation and prevented FRP rupture at the crack position. Finite element analysis was then conducted and the proposed FE model was verified against the recorded experimental data. The influence of various parameters as FRP sheet length, tensile modulus and the number of layers were studied. The moment capacity of damaged square-CFST beams was improved up to 77.6% when repaired by using four layers of CFRP, however, this caused a dramatic decrease in beam deflection. U-wrapping of notched-CFST beam with 0.75 of its length provided a comparable behaviour as wrapping the full length of the beam.

내부 구속 중공 CFT 기둥의 내진 성능 평가 (Evaluation of Seismic Performance for an Internally Confined Hollow CFT Column)

  • 한택희;김성남;강영종
    • 한국강구조학회 논문집
    • /
    • 제19권1호
    • /
    • pp.53-65
    • /
    • 2007
  • 새로운 형식의 기둥인 내부 구속 중공 콘크리트 충전 튜브 기둥(내부 구속 중공 CFT 기둥, ICH CFT column ; Internally Confined Hollow CFT Column)의 내진 성능 평가 실험을 수행하였다. 준정적 실험을 통하여 2가지 종류의 ICH CFT 기둥과 일반 중실 RC 기둥의 내진 성능을 비교 평가 하였다. 각각의 기둥 시험체에 대해 최대 하중과 변위의 관계를 측정하였으며, 이를 바탕으로 연성도, 소산에너지, 등가 감쇠비, 손상 지수가 계산되었다. 실험 결과 ICH CFT 기둥은 중실 RC 기둥에 비해 약 2배의 모멘트에 저항을 하였으며, 에너지의 흡수와 소산에서도 1.5배 정도의 성능을 보여주어, ICH CFT 기둥이 일반 중실 RC 기둥보다 더 뛰어난 성능을 가짐을 보여주었다.

신형상 U형 하이브리드 합성보와 기둥 접합부의 내진성능에 관한 연구 (Study on the Cyclic Seismic Testing of U-shape Hybrid Composite Beam-to-Composite Column Connections)

  • 김성배;김상섭;유덕수
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.47-59
    • /
    • 2013
  • 본 연구는 신형상 U형 합성보의 1차 휨실험에 연이은 2차 연구로 U형 합성보와 기둥 접합부의 내진성능시험이다. 실험 변수는 기둥의 종류와 보 춤, 보 상부 플레이트 연속유무, 보 단부 철근 수 등으로 3개의 실험체를 제작하였다. 기둥의 종류는 철골 철근콘크리트 기둥과 CFT 형상의 ACT기둥이며, 보 춤은 300, 500(mm)이다. 접합부상세는 일반적으로 많이 적용하고 있는 짧은 브라켓을 활용한 볼트 접합부이다. 실험결과 변형능력은 2~4(%)의 층간변위각을 확보하였으며, 최대모멘트는 부휨모멘트의 경우 공칭모멘트 이상의 내력이 나타났다.

조립형 프리캐스트 콘크리트 보강재를 가지는 비좌굴가새의 이력특성 (Hysteresis Characteristics of Buckling Restrained Brace with Precast RC Restraining Elements)

  • 신승훈;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.72-84
    • /
    • 2016
  • 종래 브레이스시스템은 횡력저항 및 층변위제어에 효율적이며 골조물량 감소에 따른 경제성이 향상되어 일반적인 강구조 횡력저항시스템으로 적용되고 있다. 그러나 압축측에서 항복응력에 도달하기 전 가새의 좌굴이 발생하여 충분한 내력을 발휘하지 못하고, 내력열화형의 이력거동으로 불안정상태가 된다. 좌굴에 의한 내력저하 개선시스템으로 중심재를 구속하여 좌굴방지가 가능한 비좌굴가새는 심재의 항복 이후에도 안정적인 이력특성을 나타내어 종래 브레이스에 비하여 에너지흡수능력이 우수하다. 최근 10년간 미국, 일본 및 대만에서 매우 다양한 형상의 비좌굴가새가 제안되었으나, 기존의 실험연구에서는 그 형상이 매우 제한적인 경향을 보이고 있다. 본 연구에서는 조립형 Precast RC 보강재를 가지는 비좌굴가새를 제작하고 이력특성을 평가하기 위한 부재실험을 수행하였다. 또한 실험결과를 AISC(2005)의 요구조항과 비교하였다.

프리캐스트 모듈러 피어캡의 구조성능 평가 (Evaluation of Structural Performance of Precast Modular Pier Cap)

  • 김동욱;심창수
    • 콘크리트학회논문집
    • /
    • 제27권1호
    • /
    • pp.55-63
    • /
    • 2015
  • 사전제작 기술은 교량을 더 안전하고 주변과 친화적인 환경을 구축하며 작업 환경에 제한이 있을 경우에도 품질과 내구성을 개선하며 공사를 수행할 수 있다. 콘크리트 충전강관을 이용한 모듈러 하부구조 교각을 제안하였다. 프리캐스트 피어캡은 피어테이블과 프리스트레스를 도입한 프리캐스트 세그먼트로 구성되어 있다. 피어테이블은 매입형 강재를 사용하여 응력의 집중을 완화하였다. 피어캡과 교각은 4개 또는 6개의 CFT기둥으로 연결된다. 피어캡의 전단강도는 피어테이블에서 연장시킨 전단 스터럽에 의해 저항하게 된다. 횡방향 프리스트레스 힘은 사용하중에 의한 인장 응력을 제어하기 위하여 도입되었다. 이 논문에서는 모듈러 구조의 유효성을 정적실험을 통하여 평가하였다. 제안된 피어캡은 설계 요구사항들을 연속 철근과 프리스트레스에 의해 만족시켰다. 모듈러 구조의 표준화는 급속교체 및 교량의 급속시공에 효과적으로 사용될 수 있다.