• Title/Summary/Keyword: concrete mixture proportions

Search Result 49, Processing Time 0.022 seconds

Basic Mixing and Mechanical Tests on High Ductile Fiber Reinforced Cementless Composites (고인성 섬유보강 무시멘트 복합체의 기초 배합 및 역학 실험)

  • Cho, Chang-Geun;Lim, Hyun-Jin;Yang, Keun-Hyeok;Song, Jin-Kyu;Lee, Bang-Yeon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.121-127
    • /
    • 2012
  • Cement has been traditionally used as a main binding material of high ductile fiber reinforced cementitious composites. The purpose of this paper is to investigate the feasibility of using alkali-activated slag and polyvinyl alcohol (PVA) fibers for manufacturing high ductile fiber reinforced cementless composites. Two mixture proportions with proper flowability and mortar viscosity for easy fiber mixing and uniform fiber dispersion were selected based on alkali activators. Then, the slump flow, compression, uniaxial tension and bending tests were performed on the mixes to evaluate the basic properties of the composites. The cementless composites showed an average slump flow of 465 mm and tensile strain capacity of approximately 2% of due to formation of multiple micro-cracks. Test results demonstrated a feasibility of manufacturing high ductile fiber reinforced composites without using cement.

Studies on Properties of Superplasticized Fly Ash Concrete (고류동화제(高流動化劑)를 사용한 플라이애쉬 콘크리트의 제성질(諸性質)에 관한 연구(硏究))

  • Kim, Seong Wan;Sung, Chan Yong;Cho, Il Ho
    • Korean Journal of Agricultural Science
    • /
    • v.16 no.2
    • /
    • pp.212-224
    • /
    • 1989
  • This paper reports results of an investigation to determine properties of superplasticizered fly ash concrete. The mixture proportions of fly ash were 0, 10, 20 and 30%, by weight of cement, and superplasticizer was added as a percentage of fly ash, 0, 0.6, 12 and 1.8%. To investigate the effective use of the superplasticized fly ash concrete, the basic data were analyzed. The results obtained were summarized as follows : 1. The unit water content was decreased by 1%, 6% and increased by 2% to the ratio of addition of fly ash 10%, 20%, 30%, respectively, but in case of the superplasticized fly ash concrete, it was decreased by 3~16%, 4~14% and 10~17%, at 0.6, 12, and 1.8% dosage of superplasticizer, respectively. 2. In the properties of the fresh fly ash concrete, the slump loss was reduced with the ratio of replacement of fly ash increased, and with times went by. When using superplasticizer in fly ash substituting concrete, the fludity in the concrete was not decreased. 3. The compressive strength of fly ash concrete at early ages was lower than that of ordinary concrete. At the later age of 28 days, the compressive strength with 20% addition of fly ash was increased than that of ordinary concrete. In cased of 10%, 30% addition of fly ash, the compressive strength were reduced. From this, it was proved that the optimum amount of fly ash appears to be about 20%. The compressive strength at all ages of superplasticized fly ash concrete was significantly higher than that of fly ash concrete, with increasing fly ash content. 4. In case of the tensile strength, the effects of the increasing strength with the ages were similar to those of the compressive strtength, and at the later ages was seen a decreasing tendency of strengths. 5. The correlation between compressive and tensile strength of superplasticized fly ash concrete was highly significant. The multiple regression equations of compressive and tensile strength were obtained on a function of the mixture proportion of fly ash and the addition of superplasticizer. The relation between compressive and tensile strength is higher than for ordinary concrete. The strength ratio is 7~11, and it is higher than that of ordinary concrete, 8~10. 6. Bulk density was decreased by 1~3% compared with ordinary concrete with the mixture proportion of fly ash increased, 10~30%, and decreased by 1~2% with the superplasticizer added 0.6~1.8%.

  • PDF

An Experimental Study for Characteristics Evaluation of Cement Mortar Using Infrared Thermography Technique (적외선 화상기법을 이용한 시멘트 모르타르 특성의 실험적 평가)

  • Kwon, Seung-Jun;Maria, Q. Feng
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.53-59
    • /
    • 2010
  • Recently, NDTs (Non-Destructive Techniques) using infrared camera are widely studied for detection of damage and void in RC (reinforced concrete) structures and they are also considered as an effective techniques for maintenance of infrastructures. The temperature on concrete surface depends on material and thermal properties such as specific heat, thermal conductivity, and thermal diffusion coefficient. Different porosity on cement mortar due to different mixture proportions can show different heat behavior in cooling stage. The porosity can affect physical and durability properties like strength and chloride diffusion coefficient as well. In this paper, active thermography which uses flash for heat induction is utilized and thermal characteristics on surface are evaluated. Samples of cement mortar with W/C (water to cement ratio) of 0.55 and 0.65 are prepared and physical properties like porosity, compressive strength, and chloride diffusion coefficient are evaluated. Then infrared thermography technique is carried out in a constant room condition (temperature $20{\sim}22^{\circ}C$ and relative humidity 55-60%). The mortar samples with higher porosity shows higher residual temperature at the cooling stage and also shows reduced critical time which shows constant temperature due to back wall effect. Furthermore, simple equation for critical time of back wall effect is suggested with porosity and experimental constants. These characteristics indicate the applicability of infrared thermography as an NDT for quality assessment of cement based composite like concrete. Physical properties and thermal behavior in cement mortar with different porosity are analyzed in discussed in this paper.

Design of Fiber Reinforced Cement Matrix Composite Produced with Limestone Powder and Flexural Performance of Structural Members (석회석 미분말을 혼입한 시멘트계 매트릭스 섬유복합재료의 설계 및 구조부재의 휨성능)

  • Hyun, Jung-Hwan;Kim, Yun-Yong
    • Composites Research
    • /
    • v.29 no.6
    • /
    • pp.328-335
    • /
    • 2016
  • The purpose of this study is to develop fiber reinforced cement matrix composite (ECC) produced with limestone powder in order to achieve high ductility of the composite, and to evaluate flexural performance of structural members made with ECC. Four kinds of mixture proportions were determined on the basis of the micromechanics and a steady state cracking theory considering the matrix fracture toughness and fiber-matrix interfacial characteristics. The mechanical properties of ECC, represented by strain-hardening behavior in uniaxial tension, were investigated. Also, strength property of the composite was experimentally evaluated. Two structural members made with ECC were produced and tested. Test results were compared with those of conventional concrete structural members. Increased limestone powder contents of ECC provides higher ductility of the composites while generally resulting in a lower strength property. ECC structural members exhibited higher flexural ductility, higher flexural load-carrying capacity and tighter crack width compared to conventional structural members.

Cyclic Responses of Steel Reinforced ECC Column under Reversed Cyclic Loading Conditions (철근 보강된 ECC 기둥의 반복하중에 대한 이력거동)

  • Hyun, Jung-Hwan;Shim, Young-Heung;Bang, Jin-Wook;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • In this study, experimental research was carried out to evaluate steel reinforced ECC (Engineered Cementitious Composites) column, which exhibits excellent crack control property and highly ductile behavior. Ordinary portland cement and high volume fly ash were used as binding materials in the mixture proportions for the purpose of achieving a high level of multiple cracking property with the tightly controlled crack width. To compare with the cyclic behavior of steel reinforced ECC column specimen, a conventional reinforced concrete column was prepared and tested under reversed cyclic loading condition. Based on the cyclic load test, ECC column exhibited higher cyclic behavior, compared to the conventional RC column, in terms of load carrying capacity and energy dissipation capacity.

The strength properties of alkali-activated silica fume mortars

  • Saridemir, Mustafa;Celikten, Serhat
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.153-159
    • /
    • 2017
  • In this study, the strength properties of alkali-activated silica fume (SF) mortars were investigated. The crushed limestone sand with maximum size of 0-5 mm and the sodium meta silicate ($Na_2SiO_3$) used to activate the binders were kept constant in the mortar mixtures. The mortar specimens using the replacement ratios of 0, 25, 50, 75 and 100% SF by weight of cement together with $Na_2SiO_3$ at a constant rate were produced in addition to the control mortar produced by only cement. Moreover, the mortar specimens using the replacement ratio of 4% titanium dioxide ($TiO_2$) by weight of cement in the same mixture proportions were produced. The prismatic specimens produced from eleven different mixtures were de-moulded after a day, and the wet or dry cure was applied on the produced specimens at laboratory condition until the specimens were used for flexural strength ($f_{fs}$) and compressive strength ($f_c$) measurement at the ages of 7, 28 and 56 days. The $f_{fs}$ and $f_c$ values of mortars applied the wet or dry cure were compared with the results of control mortar. The findings revealed that the $f_c$ results of the alkali activated 50% SF mortars were higher than that of mortar produced with Portland cement only. It was found that the $f_{fs}$ and $f_c$ of alkali-activated SF mortars cured in dry condition was averagely 4% lower than that of alkali-activated SF mortars cured in wet condition.

Correlation Between Flexural Toughness and Cracking Characteristics of Micro-fiber Reinforced Mortar According to Fiber Contents (마이크로 섬유보강 모르타르의 휨 인성과 균열 특성의 상관관계)

  • Shin, Kyung-Joon;Jang, Kyu-Hyou;Kim, Eui Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.249-257
    • /
    • 2008
  • Various methods have been used to reinforce the cementitious material such as mortar and concrete that have weak tensile strength. Major reinforcing method is to mix matrix with fibers which have strong tensile strength. Recently, micro-fiber reinforced mortar has been studied which removes coarse aggregate and uses micro-fiber with small diameter in order to homogenize the matrix properties and maximize the performance of fiber. Performance of micro-fiber reinforced mortar showing multiple cracking behavior is hardly represented only by the flexural toughness. Therefore, This paper reports the cracking behavior as well as mechanical behavior for various mixtures which have different fiber type and mixture proportions to find the proper parameter representing the cracking characteristic. Correlations between flexural toughness and various cracking characteristics such as cracking area, width and number are explored. As a result, it is found that flexural toughness, volume of fiber and number of cracks are suitable for representing the characteristics of micro-fiber reinforced mortar.

Experimental Study on the Development of Electromagnetic Pulse Shielding Inorganic Paint Using Carbon Materials (탄소 재료를 사용한 전자파 차폐 무기계 도료 개발에 관한 실험적 연구)

  • Kyong-Pil Jang;Tae-Hyeob Song
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.234-243
    • /
    • 2023
  • The electromagnetic pulse(EMP) is a general term for high-output electromagnetic waves, and is classified into EMP generated from nuclear weapons, non-nuclear EMP, and EMP generated by natural phenomena. Electromagnetic pulses are means that can cause fatal damage to all electronic devices with electromagnetic elements, such as communication devices, mobile phones, computers, TVs, and means of transportation. In this study, the electromagnetic pulse(EMP) shielding effectiveness evaluation of paints according to the type and amount of carbon material was conducted to develop EMP shielding inorganic paint using carbon materials. In order to analyze the improvement of compatibility and dispersibility between materials, experiments were conducted two times with about 27 types of mixture proportions, and the electromagnetic pulse shielding effectiveness was evaluated by the electrical resistance measurement method. As a result of applying the EMP shielding paint developed through this study to shielding concrete, it was confirmed that the shielding performance was improved from about 25 dB to a maximum of 40 dB.

Enhancing the Performance of Polypropylene Fiber Reinforced Cementitious Composite Produced with High Volume Fly Ash (폴리프로필렌 섬유로 보강된 하이볼륨 플라이애시 시멘트 복합재료의 성능 향상 기법)

  • Lee, Bang Yeon;Bang, Jin Wook;Kim, Yun Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.118-125
    • /
    • 2013
  • The synthetic fibers including Polyvinyl alcohol and Polyethylene fibers have been successfully used in the manufacture of high ductile fiber reinforced cementitious composites. Polypropylene (PP) fiber has also been used in composites, not for the purpose of achieving a high level of tensile ductility but to improve the fire resistance performance of concrete exposed to high temperatures. This paper discusses the method for enhancing the performance of composites supplemented with PP fiber. Five types of mixture proportions were designed with high volume fly ash for testing the performance of composites. Type I cement and fly ash F were used as binding materials. The water-to-binder ratio was 0.23~0.25, and the amount of PP fiber used was 2 vol%. Polystyrene bead were also used to increase the tensile ductility of composites. A series of experiments including slump, density, compression and uniaxial tension tests were performed to evaluate the performance of cementitious composites supplemented with PP fiber. From the test results, it was exhibited that the performance of composites supplemented with PP fiber can be enhanced by adopting the mechanics and statistics theory.