• Title/Summary/Keyword: concrete floor

Search Result 584, Processing Time 0.042 seconds

Experimental Model Analysis of Double Floor (실험적 모드해석법에 의한 이중바닥구조의 동특성 해석)

  • 변근주;노병철;이헌주;이호범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.207-212
    • /
    • 1993
  • When constructing highly precise production plants, for example, super LSI plants or semiconductor plants, it is important to take the necessary control countermeasures into consideration to obtain the working microvibration environment, which is directly related to product precision. Working environment of a clean room means vibration-free and there are only ultra-miro vibration which human cannot sense. In order to provide an place having a vibration-free working environment with only ultra-micro vibration it is necessary to posses a great number of vibration isolation technlogies, wide-ranging and abundant survey and teat data, and a high level of knowledge enabling comprehensive judgments to be made. In this study, experimental modal analysis is used to analyze the dynamic characteristics of double floor for vibration-proofing near apparatus which generate vibration. It is concluded that the double floor system with rubber pad inserted between floor panel and pedestal is good for vibration proof.

  • PDF

An Experimental Study for Crack Prevention of Floor Mortar (바닥용 모르타르의 균열방지를 위한 실험적 연구)

  • 정재동;김진근;최응규;이칠성;이상순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.202-207
    • /
    • 1996
  • Recently, the mortar crack on floor is very serious in construction field, e.g. the crack due to plastic shrinkage and the crack due to drying shrinkage. To prevent this kind of crack, optimum mix propertions not only satisfying the required workability but also minimizing the unit water content were selected. And the expansion admixtures were used to compensate the shrinkage of mortar. This study shows that water/cement ratio used in construction field is about 64%. Even if we reduce water/cement ratio of mortar by the appropriate use the fine aggregate with high fineness modulus and superplastizer, floor mortar can have the required workability. The equations between mortar flow and water/cement ratio, sand/cement ratio, fineness modulus of fine aggregate were proposed in this study. And this equation may provide available mix proportions of floor mortar.

  • PDF

Evaluation of Floor Vibration Existing in Apartment Building (RC 아파트 바닥의 수직진동 성능 평가)

  • 이민정;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.967-972
    • /
    • 2003
  • In recent years building floors has become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have longer period so that they would be more vulnerable to the floor vibration. This study attempts to evaluate the performance of the floors in typical apartment buildings. Four different floors with the area of 43.2$m^2$, 41.44$m^2$, 34.5$m^2$, and 28.89$m^2$ were investigated. The guideline provided by AISC(997) and human perception level of Korean people proposed by S. W. Han(2003) are used to check the acceptability of the floor vibration.

  • PDF

Proposing the Thickness of 2-Way Slab Satisfying Floor Vibration Criteria for Several Boundary Condition (수직진동에 대한 사용성을 고려한 경계조건에 따른 2방향 슬래브 최소두께 제안)

  • Kim, Dong-Hyun;Lee, Min-Jung;Han, Sang-Whan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.199-202
    • /
    • 2005
  • KCI 2003 provides minimum thickness of slab that satisfies serviceability to static displacement. Previous study (Han, et al. 2003) showed the several slabs that designed according to minimum thickness criteria had floor vibration problem. In this study, evaluate the floor vibration serviceability of KCI 2003 minimum thickness requirements for 2-way flat plate and propose the minimum thicknesses of 2-way slabs that satisfy floor vibration criteria according to several boundary condition. For this purpose, one degree of freedom model is used and Monte Carlo simulation is performed.

  • PDF

Lightweight Floor Systems for Tall Buildings: A Comparative Analysis of Structural Material Efficiencies

  • Piyush Khairnar
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.145-152
    • /
    • 2023
  • Typical floor systems in contemporary tall buildings consist of reinforced concrete or composite metal deck over framing members and account for a majority of the structural weight of the building. The use of high-density materials, such as reinforced concrete and steel, increases the weight of floor systems, reducing the system's overall efficiency. With the introduction of high-performance materials, mainly mass timber products, and fiber-reinforced composites, in the construction industry, designers and engineers have multiple options to choose from when selecting structural materials. This paper discusses the application of mass timber and carbon fiber composites as structural materials in floor systems of tall buildings. The research focused on a comparative analysis of the structural system efficiency for five different design options for tall building floor systems. Finite Element Analysis (FEA) method was adopted to develop a simulation framework, and parametric structural models were simulated to evaluate the structural performance under specific loading conditions. Simulation results revealed the advantages of lightweight structural materials to improve system efficiency and reduce material consumption. The impact of mechanical properties of materials, loading conditions, and issues related to fire engineering and construction were briefly discussed, and future research topics were identified in conclusion.

Composite Wood-Concrete Structural Floor System with Horizontal Connectors

  • SaRibeiro, Ruy A.;SaRibeiro, Marilene G.
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The concept of horizontal shear connection utilization on wood-concrete beams intends to be an alternative connection detail for composite wood-concrete decks. The volume of sawn-wood is over three times more expensive than concrete, in Brazil. In order to be competitive in the Brazilian market we need a composite deck with the least amount of wood and a simple and inexpensive connection detail. This research project uses medium to high density tropical hardwoods managed from the Brazilian Amazon region and construction steel rods. The beams studied are composed of a bottom layer of staggered wood boards and a top layer of concrete. The wood members are laterally nailed together to form a wide beam, and horizontal rebar connectors are installed before the concrete layer is applied on top. Two sets of wood-concrete layered beams with horizontal rebar connectors (6 and 8) were tested in third-point loading flexural bending. The initial results reveal medium composite efficiency for the beams tested. An improvement on the previously conceived connection detail (set with six connectors) for the composite wood-concrete structural floor system was achieved by the set with eight connectors. The new layout of the horizontal rebar connectors added higher composite efficiency for the beams tested. Further analysis with advanced rigorous numerical Finite Element Modeling is suggested to optimize the connection parameters. Composite wood-concrete decks can attend a large demand for pedestrian bridges, as well as residential and commercial slabs in the Brazilian Amazon.

EXPERIMENT OF CONCRETE FLOOR FINISHING ROBOT

  • Woo, Kwang-Sik;Lee, Ho-Gil;Kim, Jin-Young;Song, Jae-Bok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1480-1484
    • /
    • 2004
  • In this paper, a self-propulsive and small concrete floor finishing trowel robot with twin trowels is proposed. Due to the small size and omni-directional moving capability, it is adequate for small space such as apartment. By adjusting the posture of trowels, it can move in any direction without wheels. We used cheap PIC processor for the cost saving design of the modules and adopted mode processors for easy operation of control stick. For the position control of the robot, we made a motion control algorithm appealing to the stepping motor driver module and the wireless communication module between the robot and PC (or control stick). In this paper, we discuss the control problem of the floor finishing robot in order to move to the right position. By comparing experimental result with simulation, we show the validity of the robot mechanism, sensors, and the control system.

  • PDF

Comparing floor height reduction effect of slim floor system with square steel pipe (각형강관을 이용한 슬림플로어 시스템의 층고절감효과 비교)

  • Cho, Youn-Jin;Rhim, Hong-Chul;Kim, Dae-You;Lyu, Seung-Il;Kim, Do-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.56-57
    • /
    • 2017
  • In recent years, new construction methods have been required to reduce the construction cost and increase the available area in an environment where construction work is frequently performed in a narrow urban area like Korea. As a result of these studies, slim floor composite beam has been suggested. Slim floor composite beam can reduce required depth because web of steel beam is embedded in the slab, so it is effective to reduce floor height and increase the available area. The purpose of this study is the floor height reduction evaluation by comparing system consisting of reinforced concrete, steel, and slim floor using square-shape steel pipe. After doing structural design for a typical plan, checked effectiveness by comparing each design plan. It is proven that slim floor composite beam can reduce required depth effectively comparing required materials of other system.

  • PDF