• Title/Summary/Keyword: concrete durability

Search Result 2,168, Processing Time 0.03 seconds

A Study on the Reduction of Combined Deterioration by Mixing Latex in Base Concrete (바탕콘크리트의 라텍스 혼입에 따른 복합열화 저감에 관한 연구)

  • Kim, Dae-Geon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.101-102
    • /
    • 2023
  • This study aims to mix the base concrete by mixing latex to improve the durability performance to reduce the composite deterioration of the base concrete. Latex fiber has high resistance to freezing and thawing, adhesion, and deicing agent (calcium chloride), and it is used to secure long-term durability to reduce cracking and compound deterioration of concrete. In addition, through experiments, we are trying to find ways to improve the strength of concrete by studying the mixing of the appropriate mixing ratio of latex.

  • PDF

Feasibility of utilizing oven-drying test to estimate the durability performance of concrete

  • Chen, How-Ji;Tang, Chao-Wei;Peng, Hsien-Sheng
    • Computers and Concrete
    • /
    • v.8 no.4
    • /
    • pp.389-399
    • /
    • 2011
  • The increasing concern for reinforced concrete structure durability has been justifying in many ways in the last few decades. However, there is no perfect durability test method till now. In this research an alternative method, which is based on the cumulative moisture loss percent of the concrete specimens after oven-drying, was proposed to estimate the durability performance of the concrete. Two temperatures were considered for the oven-drying tests: $100^{\circ}C$ and $200^{\circ}C$. Test results showed that oven-drying at $200^{\circ}C$ was obviously an unsuitable procedure to preserve the fragile microstructure of cement-based materials. By contrast, experimental results through oven-drying at $100^{\circ}C$ allowed estimating the moisture loss percent of cement-based materials in a more rational manner. Moreover, the magnitudes of the cumulative moisture loss percent obtained from oven-drying tests at $100^{\circ}C$ for 48 hours have good correlations with the data of other well-known methods, namely, electrical resistance test, water permeability test, and mercury intrusion porosimetry test. This investigation established that regarding the oven-drying test as one of the tests for evaluating the potential durability of concrete is considerably practicable.

Strength and Durability Properties by Concrete Type (콘크리트 종류에 따른 강도 및 내구성 특성)

  • 이병덕;심대원;양우석;안태송
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.189-194
    • /
    • 2000
  • The optimum mix proportioning of concrete is to produce a concrete which satisfies the strength, workability and durability required with minimum component of materials. However in practice the cement content of mix proportioning in construction field is normally higher then required. In this study, the existing mix proportioning of concrete currently used in Korea Highway Corporation has been reviewed by reducing 10kg of cement content by 3~5 strength in strength and workability during the first year of this project. The optimum mix design is established based on the results of the above review and durability were examined during the second year. The experimental results though 2 year show that 103~0% of the reduction of cement content still satisfies the specified strength of concrete and produces higher durability concrete.

  • PDF

Strength and durability of concrete in hot spring environments

  • Chen, How-Ji;Yang, Tsung-Yueh;Tang, Chao-Wei
    • Computers and Concrete
    • /
    • v.6 no.4
    • /
    • pp.269-280
    • /
    • 2009
  • In this paper an experimental study of the influence of hot springs curing upon concrete properties was carried out. The primary variables of the investigation include water-to-binder ratio (W/B), pozzolanic material content and curing condition. Three types of hot springs, in the range $40-90^{\circ}C$, derived from different regions in Taiwan were adopted for laboratory testing of concrete curing. In addition, to compare with the laboratory results, compressive strength and durability of practical concrete were conducted in a tunnel construction site. The experimental results indicate that when concrete comprising pozzolanic materials was cured by a hot spring with high temperature, its compressive strength increased rapidly in the early ages due to high temperature and chloride ions. In the later ages, the trend of strength development decreased obviously and the strength was even lower than that of the standard cured one. The results of durability test show that concrete containing 30-40% Portland cement replacement by pozzolanic materials and with W/B lower than 0.5 was cured in a hot spring environment, then it had sufficient durability to prevent steel corrosion. Similar to the laboratory results, the cast-inplace concrete in a hot spring had a compressive strength growing rapidly at the earlier age and slowly at the later age. The results of electric resistance and permeability tests also show that concrete in a hot spring had higher durability than those cured in air. In addition, there was no neutralization reaction being observed after the 360-day neutralization test. This study demonstrates that the concrete with enough compressive strength and durability is suitable for the cast-in-place structure being used in hot spring areas.

Reforming Property of Tile and Concrete Surface layer Using Self-cleaning Concrete Impregnant (Self-cleaning 침투성 함침제의 적용에 따른 타일 및 콘크리트 표층부의 개질특성)

  • Song, Hun;Jeon, Chan-Soo;Kim, Young-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.13 no.4
    • /
    • pp.61-68
    • /
    • 2013
  • Concrete structure is not the only material vulnerable to physical and chemical processes of deterioration associates with severe conditions. Deterioration of the concrete structure, however, occurs more progressively from the outside of the concrete exposed to severe conditions. Especially, Carbonation, chloride ion attack is more important factor of concrete durability. This study is interested in manufacturing the self-cleaning concrete surface impregnant including TEOS, lithium silicate for the repair of the exposed concrete surface and the color concrete requiring the advanced function in view of the concrete appearance. Form the results, TEOS and lithium silicate are very effective that increasing the concrete durability using self-cleaning concrete impregnant. Self-cleaning concrete impregnant specimens is satisfied with performance requirement of KS standard in adhesion test in tension but the reinforcement of concrete substrate is slight. So, the self-cleaning concrete impregnant of this study is more desirable for the improvement of durability rather than the reinforcement.

The Effects of Superplasticizers on the Engineering Properties of Plain Concrete

  • Park, Seung-Bum
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.29-43
    • /
    • 1999
  • The effects of superplasticizers on fresh and hardened concrete were investigated. The experimental program included tests on the workability and slump loss, bleeding, setting time, air content, compressive, tensile and flexural strength, permeability, shrinkage, freeze-thaw durability and creep deformation. Properties of superplasticized concrete were compared with those of conventional and base concretes. Superplasticizers were observed to have an appreciable fluidifying action in fresh concrete. They permitted a significant water reduction while maintaining the same workability. Bleeding of superplasticized concrete was much lower than that of conventional concrete of the same consistency. This indicates that the use of superplasticizers did not affect the tendency of segregation of fresh concrete. The compressive, tensile, and flexural strengths of superplasticized concrete were significantly higher than those of conventional concrete. The permeability and drying shrinkage and creep of superplasticized concrete were less than those of conventional concrete, but there were no significant differences between base and superplasticized concrete. Compared with base concrete, non-air-entrained superplasticized concrete had slightly higher freeze-thaw durability. and superplasticized concrete with an appropriate amount of entrained air Eave even better resistance to freezing and thawing.

  • PDF

ASSESSMENT OF PROPERTIES AND DURABILITY OF FLY ASH CONCRETE USED IN KOREAN NUCLEAR POWER PLANTS

  • Cho, Myung-Sug;Noh, Jae-Myoung
    • Nuclear Engineering and Technology
    • /
    • v.44 no.3
    • /
    • pp.331-342
    • /
    • 2012
  • Since the opening of the Shin-Kori #1,2 in 2005, fly ash mixed concrete has been used for NPP concrete structures under construction in Korea with the aim of preventing aging and improving durability. In this paper, the quality suitability of fly ash manufactured in Korea is assessed and the basic physical properties of fly ash mixed concrete and its durability against primary causes of aging are verified through experimental methods. Because of the internal structure filling effect from the pozzolanic reaction of fly ash and the resulting improvements in mechanical performance in such areas as strength and salt damage resistance, the durability of fly ash mixed concrete is shown to be superior. It is judged that this result can be applied in measures not only for improving the safety of NPP structures in operation in Korea but also for implementing effective structure life management should extending the life of structures be needed in the future.

Mechanical and Durability Performance of Roller-Compacted Concrete with Fly Ash for Dam Applications

  • Park, Chan-Gi;Yoon, Jong-Whan;Kim, Wan-Young;Won, Jong-Pil
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.57-61
    • /
    • 2007
  • This study investigated the mechanical and durability performance of roller-compacted concrete (RCC) with fly ash for dam applications. A test program studied the effects on the properties of fresh and hardened RCC with fly ash replacement ratio, as well as the long-term durability of the resulting mixture. Fly ash replaced 20, 30, 40, and 50% by mass of the cement. Laboratory tests of the compressive strength, splitting tensile strength, shear strength, chloride ion permeability, abrasion, and drying shrinkage were conducted. The test results demonstrated that 30% fly ash replacement is an optimum level, and that this mixture has excellent mechanical and durability properties.

A Study on the Effect of Experimental Factors for the Durability Inspection of High Strength Concrete (고강도콘크리트의 내구성진단을 위한 영향인자 파악을 위한 연구)

  • Kwon, Young-Jin;Kim, Moo-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.123-130
    • /
    • 1997
  • The effect of experimental factors on the Freeze-Thaw durability in the High Strength Concrete has been analyzed and investigated with [DESIGN of EXPERIMENT: L16). The Experimental parameters included the type of aggregate and mixer, the conditions of aggregates, and the difference of mixing temperature, procedure and placing, etc. It is aim of this study to provide the fundamental data on the effect of various factors on the frost resistance of high strength concrete for the practical use and research data accumulation of durability inspection. The results of this experiment indicate that the freeze-thaw durability of high strength concrete is markedly affected by the coarse aggregate source, mixing temperature and curing conditions.

  • PDF

Durability Assesment for Concrete Structures Exposed to Chloride Attack Using a Bayesian Approach (베이지안 기법을 이용한 염해 콘크리트 구조물의 내구성 평가)

  • Jung, Hyun-Jun;Zi, Goang-Seup
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.589-594
    • /
    • 2007
  • This paper is shown new method for durability assesment and design have been noticed to be very valuable has been successfully applied to predict concrete structures. This paper provides that a new approach for predicting the corrosion durability of reinforced concrete structures exposed to chloride attack. In this method, the prediction can be updated successive1y by the Bayesian theory when additional data are available. The stochastic properties of model parameters are explicitly taken into account into the model the probability of the durability limit is determined from the samples obtained from the Latin hypercube sampling technique. The new method may be very useful in designing important concrete structures and help to predict the remaining service life of existing concrete structures under chloride attack environments.

  • PDF