• Title/Summary/Keyword: concrete confinement

Search Result 653, Processing Time 0.041 seconds

Strength estimation for FRP wrapped reinforced concrete columns

  • Cheng, Hsiao-Lin;Sotelino, Elisa D.;Chen, Wai-Fah
    • Steel and Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.1-20
    • /
    • 2002
  • Fiber-Reinforced Plastics (FRP) have received significant attention for use in civil infrastructure due to their unique properties, such as the high strength-to-weight ratio and stiffness-to-weight ratio, corrosion and fatigue resistance, and tailorability. It is well known that FRP wraps increase the load-carrying capacity and the ductility of reinforced concrete columns. A number of researchers have explored their use for seismic components. The application of concern in the present research is on the use of FRP for corrosion protection of reinforced concrete columns, which is very important in cold-weather and coastal regions. More specifically, this work is intended to give practicing engineers with a more practical procedure for estimating the strength of a deficient column rehabilitated using FRP wrapped columns than those currently available. To achieve this goal, a stress-strain model for FRP wrapped concrete is proposed, which is subsequently used in the development of the moment-curvature relations for FRP wrapped reinforced concrete column sections. A comparison of the proposed stress-strain model to the test results shows good agreement. It has also been found that based on the moment-curvature relations, the balanced moment is no longer a critical moment in the interaction diagram. Besides, the enhancement in the loading capacity in terms of the interaction diagram due to the confinement provided by FRP wraps is also confirmed in this work.

Analysis and design of eccentrically loaded lightweight aggregate concrete-encased steel slender columns

  • Mostafa M.A. Mostafa
    • Structural Engineering and Mechanics
    • /
    • v.88 no.1
    • /
    • pp.25-42
    • /
    • 2023
  • This paper presents a finite element (FE) simulation of eccentrically loaded lightweight aggregate concrete-encased steel (LACES) columns with H-shaped steel sections, analytical equations are also established to estimate the columns' axial and bending moment interaction capacities. The validity of the proposed models is checked by comparing the results with experimental data. Good agreements between the test and proposed models' results are found with acceptable agreements. Moreover, design parameters, including the lightweight aggregate concrete (LWAC) strength, eccentricity, column slenderness ratio, and confinement, are studied using the FE analysis, and their efficiency factors are discussed. The results show that the ultimate axial capacity of the LACES composite columns subjected to eccentric loading is negatively affected by the increase in the columns' height, but it is positively affected by the increase of the confinement. Increasing the eccentricity and columns' height reduced the columns'stiffness. In addition, the ultimate capacity of the LACES column is significantly influenced by the LWAC strength and eccentricity, where the ultimate capacity of the LACES column is significantly increased by increasing LWAC strength, and it is remarkably decreased by increasing the eccentricity. When the eccentricity changed from zero to 70 mm, the ultimate axial capacity and stiffness decreased by 67.97% and 63.56%, respectively.

Experimental study on shear capacity of circular concrete filled steel tubes

  • Xiao, Congzhen;Cai, Shaohuai;Chen, Tao;Xu, Chunli
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.437-449
    • /
    • 2012
  • Concrete filled steel tube (CFST) structures have recently seen wide use in China, but studies of the shear problem of CFST are inadequate. This paper presents an experimental study on the shear capacity of circular concrete filled steel tube (CCFT) specimens with and without axial compression force. Shear capacity, ductility, and damage modes of CCFTs were investigated and compared. Test results revealed the following: 1) CCFTs with a small shear span ratio may fail in shear in a ductile manner; 2) Several factors including section size, material properties, shear span ratio, axial compression ratio, and confinement index affect the shear capacity of CCFTs. Based on test results and analysis, this paper proposes a design formula for the shear capacity of CCFTs.

Seismic Performance Assessment of Precast Reinforced Concrete Piers with Confinement Steel (프리케스트 RC 교각의 횡방향 철근에 따른 내진성능평가)

  • Shin, Sung-Jin;Kim, Dong-Hyun;Lee, Jae-Hoon;Sim, Jae-Beum;Shin, Hyun-Yang;Park, Dong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.457-458
    • /
    • 2009
  • Totally, 12 precast RC piers were constructed and tested to evaluate the seismic performance. Experimental variables of the specimens were confinement steel amount, longitudinal steel ratio, aspect ratio, segment connecting method. Only deformed bars were used for longitudinal steel to maximize economical efficiency.

  • PDF

Seismic Performance Evaluation of Circular RC Bridge Piers with Longitudinal Steel Lap Splice (주철근 겹이음에 따른 철근 콘크리트 교각의 내진성능 평가)

  • 이대형;박진영;정영수;조대연;이재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.187-193
    • /
    • 2001
  • The object of this research is to evaluate the seismic performance of existing circular reinforced concrete bridge piers by the Quasi-static test. Existing reinforced concrete bridge piers, which were non-seismical]y designed in accordance with the conventional provisions of Korea Highway Design Specification, are needed to rating evaluate seismic performance fur probable earthquake motions in future by developing a seismic analysis computer program with estimation algorithm. This study has been performed to verify the effect of lap spliced longitudinal steel, confinement steel type and confinement steel ratio for the seismic behavior of reinforced concrete bridge piers. Quasi-static test has been done to investigate the physical seismic performance of RC bridge piers, such as displacement ductility, energy absorption, strength degradation etc.

  • PDF

Strength and Ductility of R/C Columns with Welded Reinforcement Grids(II) - Focused on Comparisons with Columns Confined by Conventional Reinforcement (용접 띠철근으로 보강된 철근콘크리트 기둥의 강도와 연성(II) - 보편적인 띠철근 보강 기둥과의 비교를 중심으로)

  • ;Murat Saatcioglu;Mongi Grira
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.561-568
    • /
    • 1997
  • Conventional confinement reinforcement for rectangular columns consist of closely spaced perimeter hoops, overlapping hoops, and crossties. One of the potential alternatives to conventional reinforcement is a welded reinforcement grid, prefabricated to required size and volumetric ratio of transverse reinforcement. An experimental investigation was carried out to investigate the strength and deformability of reinforced concrete columns confined with welded reinforcement grids. The comparisons of the envelopes of experimental force-displacement hysteric relationships for columns confined by welded grids with analytically generated force-displacement curves for columns confined with conventional ties. In general, inelastic deformability beyond the peak, as indicate by the slope of the cuvers, was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

Structural Performance of Shearwall with Sectional Shape in Wall-type Apartment Buildings (단면현상에 따른 벽식구조 전단벽의 구조성능 평가)

  • 한상환;오영훈;오창학;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.4
    • /
    • pp.3-14
    • /
    • 2000
  • Structural performance of the walls subjected to lateral load reversals depends on various parameters such as loading history, sectional shape, reinforcement, lateral confinement, aspect ratio, axial compression, etc. Thus, the performance of the shearwall for wall-type apartment should be evaluated properly considering above parameters. This study investigates the effect of sectional shape on the structural performance of the wall. Sectional shape of the specimen is rectangular, barbell and T. Based on this experimental results, all specimens behaved as ductile fashion and failed by concrete crushing of the compression zone. Deformation index of those specimens evaluated better than 3 of ductility ratio, and 1.5% of deformability specified by seismic provision. Moreover, the performance of the rectangular shaped specimen, whose compression zone was confined with U-bar and cross tie, was as good as the barbell shaped specimen. Therefore, if we considered construction practice such as workmanship and detailing, shearwall with rectangular section may be more economical lateral load resisting system.

Field Application of Spalling Prevention Method of High Performance Concrete (고성능 콘크리트의 폭렬방지 공법 현장적용 사례)

  • Kim Kyoung-Min;Heo Young-Sun;Lee Jae-Sam;Jee Suk-Won;Lee Seong-Yeun;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.7-10
    • /
    • 2005
  • This paper is about manufacture of spalling resistance concrete and also investigates the spalling mechanism and spalling resistance method with diverse materials, mixture proportion and lateral confinement. The present work with the basic experiment achieved successful method for spatting resistance using both proper amounts of fiber contents and lateral confinement using metal lath. Moreover, the developed spatting resistance method was applied for full sized column construction in the Doosan We've Poseidon I field, located in Busan city. The author investigated the physical properties examining workability, placeability and pumpability. These studies are continuously processing to develop new technology expecting remarkable impact on the spatting resistance and fire resistance performance of high-raise building construction in the future.

  • PDF

Analytical Approach on the Concrete Columns with Welded Reinforcement Grids (격자형 용접 띠철근으로 보강된 콘크리트 기둥의 해석적 접근)

  • Choi, Chang Sik;Murat, Saatcioglu;Mongi, Grira
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.1
    • /
    • pp.137-146
    • /
    • 1999
  • Analysis of R/C columns requires modeling of the plastic hinge region, as well as nonlinear material characteristics. This becomes a challenging task in view of the nonlinearity of both steel and concrete. Furthermore, formation and progression of plasticity in the hinge is a difficult phenomenan to simulate, especially under reversed cyclic loading and decaying strength conditions. This research provide one analytical model employed in column analysis, including the analysis procedure for establishing inelastic force-deformation relationships. The analytical results show good correlation with experimental data. The employed procedure with the adopted analytical models can be used to compute inelastic displacements of concrete columns with welded reinforcement grids. The inelastic deformability beyond the peak was similar to those indicated by columns with conventional ties. The superior performance of columns with welded grids may be attributed to the improved confinement characteristics of grids associated with increased rigidity of welded ties.

  • PDF

Confining Effect of CFS on Concrete Compressive Members under Load Actions (하중이력에 따른 콘크리트 압축부재의 CFS 보강효과에 관한 연구)

  • 배주성;김경수;김재욱;고영표
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.705-708
    • /
    • 1999
  • Advanced composite materials such as carbon fiber, aramid, and glass fiber sheet, are widely used recently to strengthening existing reinforced concrete structures. The purpose of this paper was to investigate the mechanical characteristics of concrete compressive members confined with carbon fiber sheet and evaluate the efficiency of the strengthening under load actions. Uniaxal compression tests of concrete compressive members confined with carbon fiber sheet were experimentally used to develop a relationship between the axial stresses and the lateral stresses. The resulting axial and lateral strains were used to determine the confinement effect of concrete compressive members.

  • PDF