• 제목/요약/키워드: concrete, De-icing salts

검색결과 15건 처리시간 0.024초

융빙제에 의한 콘크리트의 내구성능 저하에 관한 실험적 연구 (An Experimental Study on the Deterioration of Concrete Due to De-icing Salts)

  • 고경택;류금성;이종석;김도겸;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.973-978
    • /
    • 2001
  • In clod weather regions, a strong seasonal wind brings sea salts to the land. In addition to it, recently, the spreading amount of de-icing salts has increased numerously for the purpose of removing snow and ice. Thus the salts environment around concrete structures becomes so severe that various damages of concrete due to applied salts will be brought up. It is briskly carried out study on effects of do-icing salts on concrete in America, Japan, European countries. However, there are not test method for the deterioration of concrete subjected to both freezing-thawing and chloride attack in Korea. In this study, we conduct on test for the compound deterioration subjected to both freezing-thawing and chloride attack, in order to investigate effects of de-icing salts on the deterioration of concrete.

  • PDF

융빙제 사용으로 인해 열화된 콘크리트 구조물의 내구성 조사 (The Investigation of Deteriortion of Concrete Structures due to the De-icing Salts)

  • 문한영;김성수;류재석;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 봄 학술발표회 논문집
    • /
    • pp.77-82
    • /
    • 1996
  • The study was performed for the purpose of obtaining the fundamental data to improve the durability of concrete structures due to de-icing salts. To assume the degree of concrete deterioration, soluble chloride content in concrete, the depth of carbonation and compressive strength of core specimens were measured. The porgress of corrosion of concrete bridge was electrochemically monitored. The results show that the concrete structure was deteriorated and reinforced steel in concrete was corroded due to de-icing salts.

  • PDF

Neuro-fuzzy model of concrete exposed to various regimes combined with De-icing salts

  • Ghazy, Ahmed;Bassuoni, Mohamed. T.
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.649-659
    • /
    • 2018
  • Adaptive neuro-fuzzy inference systems (ANFIS) can be efficient in modelling non-linear, complex and ambiguous behavior of cement-based materials undergoing combined damage factors of different forms (physical and chemical). The current work investigates the use of ANFIS to model the behavior (time of failure (TF)) of a wide range of concrete mixtures made with different types of cement (ordinary and portland limestone cement (PLC)) without or with supplementary cementitious materials (SCMs: fly ash and nanosilica) under various exposure regimes with the most widely used chloride-based de-icing salts (individual and combined). The results show that predictions of the ANFIS model were rational and accurate, with marginal errors not exceeding 3%. In addition, sensitivity analyses of physical penetrability (magnitude of intruding chloride) of concrete, amount of aluminate and interground limestone in cement and content of portlandite in the binder showed that the predictive trends of the model had good agreement with experimental results. Thus, this model may be reliably used to project the deterioration of customized concrete mixtures exposed to such aggressive conditions.

제설제에 노출된 서울시내 도로 시설물의 열화 환경 분석 (Evaluation on De-Icing Salts Laden Environment of Road in Seoul)

  • 윤인석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권1호
    • /
    • pp.1-9
    • /
    • 2022
  • 제설제는 동절기 도로 위의 눈을 녹이기 위하여 사용되고 있으나, 서울과 같은 대도시에서 교통이 밀집한 도로 시설물의 열화를 촉진시키는 주요 요인 중의 하나이다. 도로 시설물의 합리적인 유지관리 전략을 수립하기 위하여 제설제에 노출된 도로 시설물의 환경분석이 필요하다. 본 연구는 서울시의 적설량 및 사용된 제설제량을 토대로 외래 염소농도를 계산하였다. 평균 표면 염소이온량을 구하고자 서울시의 5년간 기후환경 및 제설제 사용량을 이용하였으며, 주간선 및 보조간선율 17.5 ~ 30%, 제설제 노출 유효면적율 50 ~ 80% 수준에서 검토하였는데, 농축 속도는 0.073~ 0.077%/년, 최대 표면 염소이온량은 콘크리트 중량대비 2.2 ~ 2.31% 수준이었다. 본 연구결과는 염소이온 프로파일의 예측 또는 콘크리트 구체의 화학적 부식정도 등으로 종합적인 유지관리 대책을 수립하는데 활용될 수 있을 것으로 기대된다.

제설제로부터 기인한 염화물의 콘크리트 확산특성 (Chloride Diffusion of Concrete in Presence of De-icing Salt)

  • 정해문;안태송
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.507-510
    • /
    • 2005
  • In winter, a large amount of de-icing salts such as $CaCl_2$, NaCl have been used on highways for road safety. They make concrete structures deteriorated. In this study, the chloride diffusion of concrete in presence of de-icing salt was investigated. The diffusion coefficient of chloride in presence of $CaCl_2$ solution was larger than in presence of NaCl solution. Therefore, it is necessary to assess chloride profile in presence of $CaCl_2$ by different way from the case in presence of NaCl solution or seawater.

  • PDF

제설제의 염화물과 동결융해의 영향을 동시에 받는 교량구조물 콘크리트 바닥판의 열화특성 (Deterioration Properties for the Concrete Decks of Bridge Structure Effected Simultaneously on the Chlorides of De-icing Salts and Freeze-Thaw)

  • 신승문;박주경;선윤숙;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.137-139
    • /
    • 2007
  • Recently, the research on durability of concrete proceed rapidly in the building industry. Deterioration due to do-icing salts occurs in practice in bridge structure, dike, barrier and similar structure. This paper reports the results of effect of chlorides on the freeze-thaw properties of concrete bridge deck in winter. The case fresh water condition where the concrete will receives a freez-thaw effect compared to decrease of durability quotient a lot occurs is a possibility of knowing from brine condition.

  • PDF

염화칼슘이 함유된 제설제로 인한 콘크리트 바닥판 단부의 염해에 관한 사례 연구 (A Case Study on Chloride Corrosion for the End Zone of Concrete Deck Subjected to De-icing Salts Added Calcium Chloride)

  • 정지승;김보헌;김일순
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.87-93
    • /
    • 2014
  • In this study, the reinforced concrete rahmen bridge damaged by the chloride attack was investigated. According to the investigation, the degraded concretes on cantilever kerb and end part were intensively observed. Thus, the chloride content test and half-cell method were performed to evaluate the degraded parts. As a result, the contents of chloride on degraded parts were C and D grade. On the other hand, the half-cell potential values of rebar in degraded concrete were measured with the minor corrosion. This rebar corrosion is expected to progressing. Chloride content D grade is due to expansion pressure by corrosion of rebar and freeze-thaw by permeate water, could see progresses rapidly degradation. In order to prevent chloride attack to concrete deck caused by deicing salts, corresponding to the chloride critical concentration must maintain grade b or at least grade c. Chloride condition evaluation standard apply to evaluation of marine structure chloride attack with chloride attack by deicing salts.

Durability studies on concrete with partial replacement of cement and fine aggregates by fly ash and tailing material

  • Sunil, B.M.;Manjunatha, L.S.;Yaragalb, Subhash C.
    • Advances in concrete construction
    • /
    • 제5권6호
    • /
    • pp.671-683
    • /
    • 2017
  • Commonly used concrete in general, consists of cement, fine aggregate, coarse aggregate and water. Natural river sand is the most commonly used material as fine aggregate in concrete. One of the important requirements of concrete is that it should be durable under certain conditions of exposure. The durability of concrete is defined as its ability to resist weathering action, chemical attack or any other process of deterioration. Durable concrete will retain its original form, quality and serviceability when exposed to its environment. Deterioration can occur in various forms such as alkali aggregate expansion, freeze-thaw expansion, salt scaling by de-icing salts, shrinkage, attack on the reinforcement due to carbonation, sulphate attack on exposure to ground water, sea water attack and corrosion caused by salts. Addition of admixtures may control these effects. In this paper, an attempt has been made to replace part of fine aggregate by tailing material and part of cement by fly ash to improve the durability of concrete. The various durability tests performed were chemical attack tests such as sulphate attack, chloride attack and acid attack test and water absorption test. The concrete blend with 35% Tailing Material (TM) in place of river sand and 20% Fly Ash (FA) in place of OPC, has exhibited higher durability characteristics.

재령에 따른 플라이 애쉬 콘크리트의 염소이온 확산특성 (Chloride Ion Diffusion Characteristics of Fly ash. Concrete with Age)

  • 이재호;이광명;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.681-686
    • /
    • 2003
  • One of the major degradation processes of reinforced concrete (RC) structure is corrosion of reinforced steel due to chloride attack. Severe environments, such as marine environment and exposure to de-icing salts, could accelerate the steel corrosion of RC structures through the chloride ion intrusion into concrete. In order to delay this degradation process, several kinds of admixtures have been used in concrete mix. In this study, effective diffusion coefficient of chloride ion ($D_{eff}$) and total passed charge of concrete with and without fly ash were measured using electrical method. It is found that fly ash concrete has much less chloride ion coefficient than ordinary concrete at later age. By analyzing the test results, $D_{eff}$ at 28 and 90 days was obtained as a function of water-binder ratio (W/B) and an equation for predicting $D_{eff}$ with age was proposed considering the decreasing rate of $D_{eff}$.

  • PDF

시멘트 콘크리트 포장의 스케일링 저항성 평가방법에 관한 실험적 연구 (An Experimental Study on Evaluation Methods for Scaling Resistance of Cement Concrete Pavement)

  • 이현기;오홍섭;심종성;심재원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권3호
    • /
    • pp.30-38
    • /
    • 2015
  • 적설한랭지의 경우, 동절기의 동해 및 적설에 의한 교통통행의 원활을 기하기 위하여 제설제를 사용한다. 이와 같은 제설염의 사용은 동결융해 및 염화물에 의해 콘크리트의 급속한 스케일링 피해를 야기시킨다. 이에 대한 피해로 인하여 콘크리트 포장은 콘크리트의 피복두께 감소에 따른 조기 열화 및 사용자의 안정성 등 여러 가지 문제를 발생시킨다. 이에 따라 국외적으로 이와 같은 현상에 대하여 평가를 하기 위해 다양한 시험 및 평가 방법이 제시되고 있다. 하지만 국내에서는 아직 평가방법에 대한 규정은 없으며, 관련 연구 또한 미미한 수준이다. 따라서 본 논문에서는 각 기관 및 나라에서 제시되고 있는 평가방법을 조사하고, 각각의 규정에 따라 실험을 수행하여 결과를 도출하여 비교 분석하였다. 나아가 이와 같은 실험방법과 실험결과의 고찰을 통하여 국내현장에 맞는 실험법을 제안하고자 한다.