• Title/Summary/Keyword: concentration of power

Search Result 2,530, Processing Time 0.029 seconds

Melatonin Suppression under LED Lighting Focused on Spectral Power Distribution Differences

  • Hong, Seong-Kwan;Kim, Kyoung-Sil;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.7-17
    • /
    • 2015
  • Changes in melatonin concentration levels by differences in CCT of white LED light focused on Spectral Power Distribution (SPD) differences compared to the same CCT of conventional fluorescent light were analyzed. For this, melatonin concentration levels in saliva samples were taken over four different experiments at seven-day intervals. In 71.4% of participants, it was confirmed that melatonin concentration is suppressed by exposure to light, and a slight difference was observed by different CCTs. In addition, Experiment II with a high CCT was relatively high in terms of the melatonin suppression rate compared to Experiment III. A key finding was the possibility that different SPDs under a particular CCT of white LED light compared to the same CCT of conventional fluorescent light could have the same effect on the melatonin suppression.

Characteristics of Superposed Discharge type Ozonizer by Variation of Inner Dielectric Vacuum

  • Chun, Byung-Joon;Lee, Kwang-Sik;Song, Hyun-Jig
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.6
    • /
    • pp.230-235
    • /
    • 2003
  • In this paper, a superposed discharge type ozonizer with an internal dielectric that can be made into a vacuum tube has been designed and fabricated. Ozone generation and discharge characteristics have been investigated in accordance with output voltage of power supply, flow-rate, discharge power and vacuum of inside internal dielectric. Pure oxygen was used as the supply gas of the ozonizer. Ozone concentration and ozone generation are gradually increased when discharge power is increased at the same flow-rate and they are both proportional to the vacuum level. As such, the maximum ozone concentration of 8840 ppm was obtained at vacuum 0.1 Torr and flow-rate 0.5 $\ell$/min.

PEDOT:PSS and Graphene Oxide Composite Hydrogen Gas Sensor (전도성 고분자 PEDOT:PSS와 산화 그래핀 복합물 수소 가스 센서)

  • Maeng, Sunglyul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.2
    • /
    • pp.69-73
    • /
    • 2018
  • The power law is very important in gas sensing for the determination of gas concentration. In this study, the resistance of a gas sensor based on poly (3, 4-ethylenedioxythiophene) polystyrene sulfonate+graphene oxide composite was found to exhibit a power law dependence on hydrogen concentration at $150^{\circ}C$. Experiments were carried out in the gas concentration range of 30~180 ppm at which the sensor showed a sensitivity of 6~9% with a response and recovery time of 30s.

Fresnel lens optics simulation with middle sized linear concentration without secondary optics (2차 광학계가 필요없는 프레넬 렌즈를 이용한 중집광 광학계 시뮬레이션)

  • Kang, Sung-Won;Kim, Yong-Sik;Sim, Chang-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.27-33
    • /
    • 2011
  • HCPV(High Concentrated PV) systems have well known for CPV market all over the world. Low concentration type silicon based modules have been introduced in the market. But low cost of standard flat silicon modules made them useless nowadays. High cost of compound semiconductor solar cell reduced cost effective cpv module production than that of recently silicon solar cell. In order to overcome increasing cost of CPV module, we study middle concentration type fresnel lens simulation using concentrated type silicon based solar cell. Linear type fresnel lens made production of CPV module without secondary optics such as light pipe or light tunnel. This type of fresnel lens design makes more cost effective solution for cpv niche market.

  • PDF

Research on the calculation method of sensitivity coefficients of reactor power to material density based on Monte Carlo perturbation theory

  • Wu Wang;Kaiwen Li;Yuchuan Guo;Conglong Jia;Zeguang Li;Kan Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4685-4694
    • /
    • 2023
  • The ability to calculate the material density sensitivity coefficients of power with respect to the material density has broad application prospects for accelerating Monte Carlo-Thermal Hydraulics iterations. The second-order material density sensitivity coefficients for the general Monte Carlo score have been derived based on the differential operator sampling method in this paper, and the calculation of the sensitivity coefficients of cell power scores with respect to the material density has been realized in continuous-energy Monte Carlo code RMC. Based on the power-density sensitivity coefficients, the sensitivity coefficients of power scores to some other physical quantities, such as power-boron concentration coefficients and power-temperature coefficients considering only the thermal expansion, were subsequently calculated. The effectiveness of the proposed method is demonstrated in the power-density coefficients problems of the pressurized water reactor (PWR) moderator and the heat pipe reactor (HPR) reflectors. The calculations were carried out using RMC and the ENDF/B-VII.1 neutron nuclear data. It is shown that the calculated sensitivity coefficients can be used to predict the power scores accurately over a wide range of boron concentration of the PWR moderator and a wide range of temperature of HPR reflectors.

Uplink Sub-channel Allocation and Power Control Algorithm Using Ranging Information in High speed Portable Internet System (휴대인터넷 시스템의 레인징 정보를 이용한 상향링크 부채널 할당 및 전력제어 알고리즘)

  • Kim, Dae-Ho;Kim, Whan-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9A
    • /
    • pp.729-736
    • /
    • 2005
  • In this paper, we introduce a new approach for the design of uplink sub-channel allocation and power control in the High-speed Portable Internet system that is based on OmMAnDD scheme. In OFDMA system, because the number of allocated sub-channel in mobile station varies from one to the whole sub-channel as in base station while mobile station's transmit power is lower than that of base station, full loading range(FLR) constraint occurs where whole sub-channel can be used and the conventional open-loop power control scheme can not be used beyond FLR. We propose a new scheme that limits the maximum sub-channel allocation number and uses power concentration gain(PCG) depending on location of mobile station, which is based on ranging in OfDMA system. Simulation results show that the proposed scheme extends the uplink coverage to the entire cell service coverage area, provides solutions for optimum utilization of radio resource and enables open-loop power control beyond FLR without extra hardware complexity.

Diagnostic techniques of aging deterioration of power transformer by insulating paper (절연지에 의한 전력용변압기 열화진단 기술)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Yoon, Yeo-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.449-452
    • /
    • 2004
  • The life of power transformer is basically dependent on the aging deterioration of insulating paper. Analysis of insulating paper for its DP value or tensile strength requires removal of a few strips of paper but direct measurement of this properties is not practical for in-service transformers. For this reason furfural analysis by HPLC has gained increasing favor as a means of estimating degradation of insulating papers in power transformers and this paper reports on the analysis of data on the concentration of furfural in oil samples from about 50 power transformers and the case study. The data showed that furfural content can estimate more accurately aging characteristics compared to concentration of CO, $CO_2$. We expect that these results can be useful to predict the aging characteristics and life diagnosis of power transformers and further the study must be continued.

  • PDF

An Internal Tritium Concentration Analysis in Urine Samples as a Function of Submission Time after Airborne Tritium Intake at Korean Pressurized Heavy Water Reactors (중수로원전 방사선작업종사자의 공기중 삼중수소 섭취 후 뇨시료 제출 시간이 체내 삼중수소 농도에 미치는 영향 분석)

  • Kim, Hee-Geun;Kong, Tae-Young;Jeong, Woo-Tae;Kim, Seok-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.184-189
    • /
    • 2009
  • In pressurized heavy water reactors, workers who enter radiation controlled areas must submit their urine samples to health physicists after radiation work; these samples are then used to monitor internal radiation exposure from tritium intake. This procedure assumes that the samples submitted represent tritium concentration inside the body at equilibrium. According to both technical reports from the International Commission on Radiological Protection and experimental results from Canadian nuclear utilities, tritium inside the body generally reaches equilibrium concentration after approximately 2-3 hours of intake. In practice, urine samples can be submitted either before the 2 hours mark or after several hours of radiation work because of the numerous tasks that workers must perform and their frequent entries during nuclear power plant maintenance. In this paper, tritium concentration in workers' urine samples was measured as a function of time submitted after radiation work. Based on the measurement results, changes in the tritium concentration inside the body and its effect on internal dose assessment were then analyzed. As a result, it was found that tritium concentration reaches equilibrium concentration before the 2 hours mark for most workers' urine samples.

Electric power generation from treatment of food waste leachate using microbial fuel cell

  • Wang, Ze Jie;Lim, Bong Su
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.157-161
    • /
    • 2017
  • Simultaneous treatment of food waste leachate and power generation was investigated in an air-cathode microbial fuel cell. A TCOD removal efficiency of $95.4{\pm}0.3%$ was achieved for an initial COD concentration of 2,860 mg/L. Maximum power density ranged was maximized at $1.86W/m^3$, when COD concentration varied between 60 mg/L and 2,860 mg/L. Meanwhile, columbic efficiency was determined between 1.76% and 11.07% for different COD concentrations. Cyclic voltammetric data revealed that the oxidation peak voltage occurred at -0.20 V, shifted to about -0.25 V. Moreover, a reduction peak voltage at -0.45 V appeared when organic matters were exhausted, indicating that reducible matters were produced during the decomposition of organic matters. The results showed that it was feasible to use food waste leachate as a fuel for power generation in a microbial fuel cell, and the treatment efficiency of the wastewater was satisfied.

A Study on the Implementation of Geographic Information System for an Intelligent Power Distribution Network with Location Informations of Power Line Communication-based Automatic Meter Reading System (전력선통신 기반 저압원격검침 시스템의 공간 정보를 활용한 지능형 배전망 지리정보시스템 구축에 관한 연구)

  • Seo, Chung-Ki;Lee, Seung-Gol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.365-369
    • /
    • 2015
  • In this paper, geographic information system(GIS) for an intelligent power distribution network was implemented with location informations acquired from automatic meter reading system, where the location informations of power line communication(PLC) modems installed at customer side were collected at data concentration units(DCUs) of headend equipment via PLC and then were transmitted to front end processor server. By displaying the connection status of the power distribution network on GIS map, operation of advanced metering infrastructure(AMI) or management of power grid system could be performed intuitionally and in real time, because the configuration state of the power grid could be easily monitored. The feasibility of the proposed system was confirmed with the especially constructed laboratory-level test bed and the verification test of the system will be carried out for a real power distribution network.