• Title/Summary/Keyword: concentration measuring test

Search Result 214, Processing Time 0.035 seconds

Interfacial Evaluation and Microfailure Sensing of Nanocomposites by Electrical Resistance Measurements and Wettability (전기저항측정법 및 젖음성을 이용한 나노복합재료의 미세파손 감지능 및 계면물성 평가)

  • Park, Joung-Man;Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Baek, Yeong-Min;Park, Ha-Seung
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.138-144
    • /
    • 2017
  • Damage sensing of polymer composite films consisting of poly(dicyclopentadiene) p-DCPD and carbon nanotube (CNT) was studied experimentally. Only up to 1st ring-opening polymerization occurred with the addition of CNT, which made the modified film electrically conductive, while interfering with polymerization. The interfacial adhesion of composite films with varying CNT concentration was evaluated by measuring the wettability using the static contact angle method. 0.5 wt% CNT/p-DCPD was determined to be the optimal condition via electrical dispersion method and tensile test. Dynamic fatigue test was conducted to evaluate the durability of the films by measuring the change in electrical resistance. For the initial three cycles, the change in electrical resistance pattern was similar to the tensile stress-strain curve. The CNT/p-DCPD film was attached to an epoxy matrix to demonstrate its utilization as a sensor for fracture behavior. At the onset of epoxy fracture, electrical resistance showed a drastic increase, which indicated adhesive fracture between sensor and matrix. It leads to prediction of crack and fracture of matrix.

Development of Enzyme Immuno Assay for Analysis of Free Prostate Specific Antigen in Serum (혈청 유리형 전립선항원 (free PSA) 측정을 위한 효소면역측정법의 개발)

  • Kyung-Ok Lee;Kyung-In Kim;Kyu-Pum Lee
    • Biomedical Science Letters
    • /
    • v.3 no.2
    • /
    • pp.107-114
    • /
    • 1997
  • Recent reports indicate that the clinical usefulness of prostate specific antigen (PSA), particulary in the differentiation of benign prostate hyperplasia from prostate cancer, can be improved by measuring the amount of free PSA in serum. Measuring free PSA is especially useful in attempts to improve diagnositc performance of PSA in the diagnostic gray zone of total PSA. The objective of this study was to develop free PSA assay kit using sandwich microplate enzyme immunoassay format. We chose a test format with polyclonal anti-PSA antibodies coated on the wells and monoclonal anti-free PSA antibodies for quantification to gain higher test sensitivity. We adpoted 10 uL of specimen and 2 hours of first incubation time with detecting antibody for free PSA EIA format using microplate. The within-day and between-day precision (%CV) in the high and low concentration ranges were below 4%. The correlation coefficient between in-house free PSA assay and commercial assay kit was r=0.9965 (slope=0.0984, y intercept=0.0173, N=27). No hook effect was found by 40 ng/mL and correlation coefficient (r) value of the fitted linear regression was over 0.995. The recovery tests were in the range of 98.9∼104.1% for free PSA. In conclusion, in-house free PSA enzyme immune assay is cost effective, simple and rapid and could be useful for the prognosis after theraphy as well as for the differential diagnosis between prostate cancer and benign prostate hyperplasia.

  • PDF

A study on lead exposure indices of male workers exposed to lead less than 1 year in storage battery industries (축전지 제조업에서 입사 1년 미만 남자 사원들의 연 노출 지표치에 관한 연구)

  • HwangBo, Young;Kim, Yong-Bae;Lee, Gap-Soo;Lee, Sung-Soo;Ahn, Kyu-Dong;Lee, Byung-Kook;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.4 s.55
    • /
    • pp.747-764
    • /
    • 1996
  • This study intended to obtain an useful information for health management of lead exposed workers and determine biological monitoring interval in early period of exposure by measuring the lead exposure indices and work duration in all male workers (n=433 persons) exposed less than 1 year in 6 storage battery industries and in 49 males who are not exposed to lead as control. The examined variables were blood lead concentration (PBB), Zinc-protoporphyrin concentration (ZPP), Hemoglobin (HB) and personal history; also measured lead concentration in air (PBA) in the workplace. According to the geometric mean of lead concentration in the air, the factories were grouped into three categories: A; When it is below $0.05mg/m^3$, B; When it is between 0.05 and $0.10mg/m^3$, and C; When it is above $0.10mg/m^3$. The results obtained were as follows: 1. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in all male workers exposed to lead less than 1 year in storage battery industries were $29.5{\pm}12.4{\mu}g/100ml,\;52.9{\pm}30.0{\mu}g/100ml\;and\;15.2{\pm}1.1\;gm/100ml$. 2. The means of blood lead concentration (PBB), ZPP concentration and hemoglobin(HB) in control group were $5.8{\pm}1.6{\mu}g/100ml,\;30.8{\pm}12.7{\mu}g/100ml\;and\;15.7{\pm}1.6{\mu}g/100ml$, being much lower than that of study group exposed to lead. 3. The means of blood lead concentration and ZPP concentration among group A were $21.9{\pm}7.6{\mu}g/100,\;41.4{\pm}12.6{\mu}g/100ml$ ; those of group B were $29.8{\pm}11.6{\mu}g/100,\;52.6{\pm}27.9{\mu}g/100ml$ ; those of group C were $37.2{\pm}13.5{\mu}g/100,\;66.3{\pm}40.7{\mu}g/100ml$. Significant differences were found among three factory group(P<0.01) that was classified by the geometric mean of lead concentration in the air, group A being the lowest. 4. The mean of blood lead concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $24.1{\pm}12.4{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $29.2{\pm}13.4{\mu}g/100ml$ ; and it was $28.9\sim34.5{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 5. The mean of ZPP concentration of workers who have different work duration (month) was as follows ; When the work duration was $1\sim2$ month, it was $40.6{\pm}18.0{\mu}g/100ml$, ; When the work duration was $3\sim4$ month, it was $53.4{\pm}38.4{\mu}g/100ml$ ; and it was $51.5\sim60.4{\mu}g/100ml$ for the workers who had longer work duration than other. Significant differences were found among work duration group(P<0.05). 6. Among total workers(433 person), 18.2% had PBB concentration higher than $40{\mu}g/100ml$ and 7.1% had ZPP concentration higher than $100{\mu}g/100ml$ ; In workers of factory group A, those were 0.9% and 0.0% ; In workers of factory group B, those were 17.1% and 6.9% ; In workers of factory group C, those were 39.4% and 15.4%. 7. The proportions of total workers(433 person) with blood lead concentration lower than $25{\mu}g/100ml$ and ZPP concentration lower than $50{\mu}g/100ml$ were 39.7% and 61.9%, respectively ; In workers of factory group A, those were 65.5% and 82.3% : In workers of factory group B, those were 36.1% and 60.2% ; In workers of factory group C, those were 19.2% and 43.3%. 8. Blood lead concentration (r=0.177, P<0.01), ZPP concentration (r=0.135, P<0.01), log ZPP (r=0.170, P<0.01) and hemoglobin (r=0.096, P<0.05) showed statistically significant correlation with work duration (month). ZPP concentration (r=0.612, P<0.01) and log ZPP (r=0.614, P<0.01) showed statistically significant correlation with blood lead concentration 9. The slopes of simple linear regression between work duration(month, independent variable) and blood lead concentration (dependent variable) in workplace with low air concentration of lead was less steeper than that of poor working condition with high geometric mean air concentration of lead. The study result indicates that new employees should be provided with biological monitoring including blood lead concentration test and education about personal hygiene and work place management within $3\sim4$ month.

  • PDF

Drivers' Workloads through the Driving Vehicle Test at Intersections (교차로 실차주행 실험을 통한 운전자 부하요인에 관한 연구)

  • Seo, Im-Ki;Park, Je-Jin;Sung, Soo-Lyeon;NamGung, Moon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.3
    • /
    • pp.112-123
    • /
    • 2012
  • Different from general roads, intersections are the points where roads having different geometric structure and traffic operation system are met, and thereby they have complicated road structure and environmental factors. Various changes in driving patterns such as collision between vehicles approaching from roads adjacent to intersections, sudden stop of vehicles upon stop sign, quick start upon green lights kept increasing traffic accidents. It is known that traffic accidents are mainly derived from human factors. This study, in order to find out factors affecting drivers' behaviors within intersections, measured physiological responses such as brain wave, sight, driving speed, and so on by using state-of-the-art measuring device. As to concentration brain wave at individual intersections, it was found out that brain wave of testes was higher at main Arterial and accident-prone intersections compared with that of subsidiary Arterial. In addition, it was detected that drivers' visual activity was widely distributed at accident-prone intersections, meaning that it enhanced cautious driving from nearby vehicles. As to major factors causing drivers' workloads, factors from nearby vehicles such as deceleration, acceleration, lane change of nearby vehicles appeared as direct factors causing drivers' workloads, clarifying that these factors were closely related to causes of traffic accidents at intersections. Results of this study are expected to be used as basic data for evaluation of safety at intersections in consideration of physiological response of drivers.

Effect of Evaluation Conditions on Electrochemical Accelerated Degradation of PEMFC Polymer Membrane (PEMFC 고분자 막의 전기화학적 가속 열화에 미치는 평가조건들의 영향)

  • Sohyeong Oh;Donggeun Yoo;Suk Joo Bae;Sun Geu Chae;Kwonpil Park
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.356-361
    • /
    • 2023
  • In order to improve the durability of the proton exchange membrane fuel cell (PEMFC), it is important to accurately evaluate the durability of the polymer membrane in a short time. The test conditions for chemically accelerated durability evaluation of membranes are high voltage, high temperature, low humidity, and high gas pressure. It can be said that the protocol is developed by changing these conditions. However, the relative influence of each test condition on the degradation of the membrane has not been studied. In chemical accelerated degradation experiment of the membrane, the influence of 4 factors (conditions) was examined through the factor experiment method. The degree of degradation of the membrane after accelerated degradation was determined by measuring the hydrogen permeability and effluent fluoride ion concentration, and it was possible to determine the degradation order of the polymer membrane under 8 conditions by the difference in fluoride ion concentration. It was shown that the influence of the membrane degradation factor was in the order of voltage > temperature > oxygen pressure > humidity. It was confirmed that the degradation of the electrode catalyst had an effect on the chemical degradation of the membrane.

Effect of Enteromorpha compressa on the physiological activities in carp, Cyprinus carpio (파래투여에 의한 잉어류의 생리활성에 관한 연구)

  • Choi, Min-Soon;Park, Kwan-Ha;Choi, Sang-Hoon;Kim, Jong-Yeon;Kim, Jong-Myeon;Cho, Jeong-Gon;Jang, Seon-Il
    • Journal of fish pathology
    • /
    • v.8 no.2
    • /
    • pp.149-156
    • /
    • 1995
  • Physiological activities of E. compressa were examined after oral and intraperitoneal(i.p.) adminstration in young(8g) Israeli and colored carp. Hematological parameters were evaluated to test physiological respose. Anti-bacterial activity was examined by counting the number of bacterial cells in the kidney, and also by measuring the change of agglutinin titers following A. sobriae infection. There was a tendency of increase in E. compressa-fed groups in total protein, albumin and glucose levels. The most marked increase was noted in the group fed with 5% E. compressa. GPT and GOT levels were reduced with the increase of E. compressa concentration. Feeding of E. compressa did not alter haematocrit(Ht) and hemoglobin (Hb) values. The number of A. sobriae was reduced in all groups intraperitoneally treated with variable concentration of E. compressa-extract. The lowest bacterial cells were found at the group intraperitoneally treated with $30{\mu}g$ of E. compressa-extract per g of colored carp($30{\mu}g/g$), indicating that the anti-bacterial activity is maximized at this concentration. The agglutinin titers were elevated in E. compressa extract-treated groups($30{\mu}g/g$) with the maximum value of $6.0{\pm}1.1$. These results indicate that E. compressa adminstration activated physiological response, and triggered a cascade for anti-bacterial reaction.

  • PDF

A Study on the Seasonal Survey of the Indoor Air Quality in New Apartment Houses (신축 공동주택의 계절별 실내공기질 실측조사에 관한 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Hwang, Gi-Huen
    • Land and Housing Review
    • /
    • v.4 no.4
    • /
    • pp.417-424
    • /
    • 2013
  • The purpose of this study was to investigate the characteristics of the indoor air quality by season. The surveyed houses were 48 new apartment complex in 2012 across the country. The houses were carried out the bakeout before the test. The measuring method was "Indoor air quality testing standards process" and the measured items were formaldehyde, benzene, toluene, ethylbenzene, xylene, styrene average emissions. All the items were more emitting during the summer. From June to September the average concentration of formaldehyde emission was higher than other seasons. The average emissions of benzene concentrations in all seasons were released in small quantities. Average emissions of toluene and ethylbenzene concentration from April to August showed slightly higher emissions. Xylene and styrene concentration showed the highest emissions at April, but without large deviations throughout the year.

Evaluation of Particulate Matter (PM2.5) Reduction through Greenwalls in Classrooms (교실 내 벽면녹화를 통한 초미세먼지(PM2.5) 저감 효과 평가)

  • Chi-Ku Choi;Ho-Hyeong Yang;Ho-Hyun Kim;Hyuk-Ku Kwon
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.4
    • /
    • pp.183-189
    • /
    • 2023
  • Background: The indoor air quality of classrooms, in which the capacity per unit area is high and students spend time together, must be managed for safety and comfort. It is necessary to develop an eco-friendly indoor air quality reduction method rather than biased management that relies solely on air purifiers. Objectives: In this study, plants and air purifiers were installed in middle school classrooms to evaluate the indoor PM2.5 reduction. Methods: Four middle school classrooms were selected as test beds. Air quality was monitored in real-time every one minute using IoT equipment installed in the classrooms, corridors, and rooftops. After measuring the background concentration, plants and air purifiers were installed in the classroom and the PM2.5 reduction effect was analyzed through continuous monitoring. Results: After installing the plants and air purifiers, the average PM2.5 concentration was 33.7 ㎍/m3 in the classrooms without plants and air purifiers, 25.6 ㎍/m3 in classrooms with plants only, and 21.7 ㎍/m3 in classrooms with air purifiers only. In the classroom where plants and air purifiers were installed together, it was 20.0 ㎍/m3. The reduction rates before and after installation were 4.5% for classrooms with plants only, 16.5% for classrooms with air purifiers only, and 27.6% for classrooms with both plants and air purifiers. The I/O ratio, which compares the concentration of PM2.5 in classrooms with corridors and outside air, also showed the lowest in the order of plants and air purifiers, air purifiers, and plant-only classrooms. Conclusions: The PM2.5 reduction effect of using plants was confirmed, and it is expected to be used as basic data for the development of environmentally-friendly indoor air quality improvement methods.

Phototoxicity Evaluation of Pharmaceutical Substances with a Reactive Oxygen Species Assay Using Ultraviolet A

  • Lee, Yong Sun;Yi, Jung-Sun;Lim, Hye Rim;Kim, Tae Sung;Ahn, Il Young;Ko, Kyungyuk;Kim, JooHwan;Park, Hye-Kyung;Sohn, Soo Jung;Lee, Jong Kwon
    • Toxicological Research
    • /
    • v.33 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • With ultraviolet and visible light exposure, some pharmaceutical substances applied systemically or topically may cause phototoxic skin irritation. The major factor in phototoxicity is the generation of reactive oxygen species (ROS) such as singlet oxygen and superoxide anion that cause oxidative damage to DNA, lipids and proteins. Thus, measuring the generation of ROS can predict the phototoxic potential of a given substance indirectly. For this reason, a standard ROS assay (ROS assay) was developed and validated and provides an alternative method for phototoxicity evaluation. However, negative substances are over-predicted by the assay. Except for ultraviolet A (UVA), other UV ranges are not a major factor in causing phototoxicity and may lead to incorrect labeling of some non-phototoxic substances as being phototoxic in the ROS assay when using a solar simulator. A UVA stimulator is also widely used to evaluate phototoxicity in various test substances. Consequently, we identified the applicability of a UVA simulator to the ROS assay for photoreactivity. In this study, we tested 60 pharmaceutical substances including 50 phototoxins and 10 non-phototoxins to predict their phototoxic potential via the ROS assay with a UVA simulator. Following the ROS protocol, all test substances were dissolved in dimethyl sulfoxide or sodium phosphate buffer. The final concentration of the test solutions in the reaction mixture was 20 to $200{\mu}M$. The exposure was with $2.0{\sim}2.2mW/cm^2$ irradiance and optimization for a relevant dose of UVA was performed. The generation of ROS was compared before and after UVA exposure and was measured by a microplate spectrophotometer. Sensitivity and specificity values were 85.7% and 100.0% respectively, and the accuracy was 88.1%. From this analysis, the ROS assay with a UVA simulator is suitable for testing the photoreactivity and estimating the phototoxic potential of various test pharmaceutical substances.

A Study on Torsional Characteristics of the Car Body Types at Cornering Motion (선회주행 시 차체의 비틀림 특성에 관한 연구)

  • Lee, Joon-Seong;Cho, Seong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.739-744
    • /
    • 2017
  • Elastic deformation and fatigue damage can cause the permanent deformation of a kart's frame during turning, affecting the kart's driving performance. A kart's frame does not contain any suspension or differential devices and, therefore, the dynamic behavior caused by torsional deformation when driving along a curve can strongly affect these two kinds of deformations. To analyze the dynamic behavior of a kart along a curved section, the GPS trajectory of the kart is obtained and the torsional stress acting on the kart-frame is measured in real time. The mechanical properties of leisure and racing karts are investigated by analyzing their material properties and conducting a tensile test. The torsional stress concentration and frame distortion are investigated through a stress analysis of the frame on the basis of the obtained results. Leisure and racing karts are tested in each driving condition using driving analysis equipment. The behavior of a kart when being driven along a curved section is investigated through this test. Because load movement occurs owing to centrifugal force when driving along a curve, torsional stress acts on the kart's steel frame. In the case of a leisure kart, the maximum torsional stress derived from the torsional fatigue limit was found to be 230 MPa, and the torsional fatigue limit coefficient was 0.65 when driving at a speed of 40 km/h. Furthermore, the driving elements during the cornering of a kart were measured based on an actual auto-test after installing a driving measurement system, and the driving behavior of the kart was analyzed by measuring its vertical displacement.