• 제목/요약/키워드: computed tomography image

검색결과 980건 처리시간 0.026초

Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

  • Joo, Ji Hyeon;Kim, Yeon Joo;Kim, Young Seok;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Su Ssan;Park, Jin-Hong;Jeong, Yuri;Ahn, Hanjong;Kim, Choung-Soo;Lee, Jae-Lyun;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.199-205
    • /
    • 2013
  • Purpose: To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Materials and Methods: Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. Results: The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. Conclusion: WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

협설만곡치아의 파노라마방사선영상소견에 대한 연구 (A study of the panoramic radiographic images of the buccolingual dilaceration)

  • 김영호;정환석;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.39-44
    • /
    • 2010
  • Purpose : We want to identify the appearance of the buccolingual root dilaceration teeth in the panoramic views and specify the characteristics of these teeth. Materials and Methods : One thousand-six patients were examined on the basis of both panoramic and CT image criteria. We diagnosed and excluded certain teeth from the samples; both prosthodontic or pathologic lesion appearing teeth and mesiodistally dilacerated ones. We meticulously discerned buccolingually dilacerated teeth in the CT images and total 48 samples were selected. The degree of severity in dilaceration was standardized by 2 types of criteria. The samples were differentiated into 3 groups and again categorized into six types showing from the panoramic views: irregular view on the root apex area, clear blunt on the root tip, stepping on root tip, double lamina dura or double tip, arrow-target shaped root, bull's eye, normal view. Results : The types of teeth selected from total 48 buccolingual root dilaceration samples were mandibular first and second molar, premolars, canines, and lateral incisors. The direction of dilaceration was an even percentage to each buccal and lingual side for most selected teeth, however, that of both canines and lateral incisors were directed in almost a buccal side. In the panoramic views, the root types of the buccolingually dilacerated teeth were irregular view on the root apex area, clear blunt on the root tip, stepping on root tip and normal types were almost always normal view. The more severity in dilareated degree, the more chances of observation in the panoramic views were clear blunt on the root tip and stepping on root tip. Conclusion : As observed in the shape of stepping on root tip or double lamina dura in the panoramic views, there can be much more probability to diagnose as a buccolingually dilacerated root.

Isolated Right Pulmonary Artery Hypoplasia with Retrograde Blood Flow in a 68-Year Old Man

  • Chang, You-Jin;Ra, Seung-Won;Chae, Eun-Jin;Seo, Joon-Beom;Kim, Won-Young;Na, Shin;Kim, Joo-Hee;Park, Tai-Sun;Park, Soo-Kyung;Park, Seong-Joon;Lee, Tae-Hoon;Ahn, Young-Chel;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • 제71권2호
    • /
    • pp.126-133
    • /
    • 2011
  • Unilateral pulmonary artery hypoplasia (UPAH) is a rare disease in adults and is frequently accompanied by a congenital cardiac anomaly at a young age. The diagnosis is usually based on computed tomography (CT), angiography, and magnetic resonance imaging (MRI). However, no reports are available on retrograde flow in patients with UPAH. We describe a 68-year-old man with isolated UPAH and retrograde blood flow. He was admitted for dyspnea on exertion for the past 23 years. His diagnosis was delayed, as his symptoms and signs mimicked his underlying pulmonary diseases, such as emphysema and previous tuberculous pleurisy sequelae. A discrepancy was detected between the results of a ventilation-perfusion scan and the CT image. This was resolved by MRI, which showed retrograde blood flow from the right to the left pulmonary artery. Using MRI, we diagnosed this patient with isolated pulmonary artery hypoplasia and retrograde flow.

혈행화된 부분층 두개골피판을 이용한 상악골 종양 적출 환자에서의 안와하벽 재건술 증례 (Inferior Orbital Wall Reconstruction with Vascularized Partial Thickness Calvarial Bone Flap in Three Cases of Maxillary Tumor)

  • 신상호;이윤정;김준식;김남균;이경석
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.49-54
    • /
    • 2009
  • 상악골 악성종양의 경우 적출 후 골편들을 이식해 상악동 전체를 재건하는 경우는 재발이 많아 잘 시행하지 않는다. 이러한 이유로 안와하연의 재건을 통해 안구 및 안면윤곽만을 재건하는데, 저자들이 시행한 혈행화된 부분 두께의 골이식(vascularized split thickeness calvarium)은 술기방법에 있어 골피판이 혈관경에서 쉽게 분리되는 성질이 있어 시행에 주의가 필요하고 혈관경을 포함한 temporalis muscle이 부피감을 주므로 미용상 불리한 점이 있는 반면에 골편의 높은 생존율이 보장된다는 장점과 공여부의 합병증이 적다는 장점을 가진다. 또한 술후 복시 현상이나 안구함몰이 관찰되지 않았다는 점이 합리적인 술기임을 지지해준다. 따라서 측두동맥 및 정맥을 혈관경으로 하는 혈행화된 두정골 부분층 이식술은 안와하벽을 재건하는데 있어 안전하게 시행가능 한 술기였음을 보고하는 바이다.

Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석 (Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning)

  • 채덕호;이장근;김광염;조완제
    • 한국지반환경공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.31-35
    • /
    • 2017
  • Chae et al.(2015)에 따르면 동결 사질토의 역학적 거동은 동결온도와 세립분 함유량에 따라 크게 영향을 받는 것으로 나타났다. 이러한 원인으로 동결온도에 따른 부동수분의 차이일 것이라는 의견과 세립분 함유량 및 간극 내 얼음에 의해 사질토 입자들 이격거리 차이에 의한 것이라는 의견이 제시되었다. 제시된 두 가지 의견 중 사질토 입자들 이격거리의 확인을 위해 micro X-ray CT 촬영을 수행하였다. X-ray CT 촬영에 의한 비파괴 검사는 최근 지반공학 분야에서 진행되고 있는 다양한 융복합 연구 중 하나로 CT 촬영을 통하여 지반재료의 내부 구조를 마이크로미터 단위의 높은 해상도를 통해 평가할 수 있는 방법이다. 본 연구에서는 -5, -10, $-15^{\circ}C$의 동결온도에서 성형된 5, 10, 15%의 세립분을 포함하고 있는 동결 사질토 공시체에 대하여 micro X-ray CT 촬영을 수행하고 기존의 개발된 이미지 해석 기법을 적용하여 동결 사질토 내의 조립질 입자들의 최단거리 및 평균거리를 통하여 세립분 함유량 및 동결온도가 조립질 입자간의 거리에 미치는 영향을 파악하고자 하였다. X-ray CT 촬영 결과, 동결온도 및 세립분 함유량은 동결 사질토 내 입자간 거리에는 큰 영향을 미치지 않는 것으로 나타났다.

구강악안면영역의 3차원 CT 영상 재형성시 역치 및 불투명도에 대한 연구 (Study of threshold and opacity in three-dimensional CT volume rendering of oral and maxillofacial area)

  • 최문경;이삼선;허경회;이원진;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.13-18
    • /
    • 2009
  • Purpose: This study was designed to determine a proper threshold value and opacity in three-dimensional CT volume rendering of oral and maxillofacial area. Materials and Methods: Three-dimensional CT data obtained from 50 persons who were done orthognatic surgery in department of oral and maxillofacial radiology of Seoul National University retrospectively. 12 volume rendering post-processing protocols of combination of threshold(100HU, 150HU, 221HU, 270HU) and opacity (58%, 80%, 90%) were applied. Five observers independently evaluated image quality using a five-point range scale. The results were analyzed by receiver operating characteristic curves, ANOVA and Kappa value. And three oromaxillofacial surgeons chose the all images that they thought proper clinically in the all of images. Results: Analysis using ROC curves revealed the area under each curve which indicated a diagnostic accuracy. The highest diagnostic accuracy appear with 100HU and 58% opacity. and the lowest diagnostic accuracy appear with 221HU and 58% opacity that are being used protocol in department of oral and maxillofacial radiology of Seoul National University. But, no statistically significant difference was noted between any of the protocols. And the number of proper images clinically that chosen by three oromaxillofacial surgeons is the largest in the cases of protocol 8 (221HU, opacity 80%) and protocol 11 (270HU, opacity 80%) in one after the other. Conclusion: Threshold and opacity in volume rendering can be controled easily and these can be causes of making an diagnostic accuracy. So we need to select proper values of these factors.

  • PDF

CT 관전압이 상용 전산화치료계획장치의 선량계산에 미치는 영향 (The Effects of the CT Voltages on the Dose Calculated by a Commercial RTP System)

  • 강세권;조병철;박희철;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.23-29
    • /
    • 2004
  • CT관전압 및 기종의 변화에 따른 전자밀도 환산곡선 값의 변화가 상용 전산화치료계획장치의 선량계산 결과에 미치는 영향을 고찰하였다. CT기종 및 관전압을 달리하며 전자밀도 환산용 팬톰에 대한 CT 영상을 얻어서 여러 조직등가물질에 대해 전자밀도와 CT수의 관계를 구하였다. 동일 전자밀도에 대해 관전압이 감소함에 따라 고밀도의 골조직으로 갈수록 큰 CT수를 보였으며, 연조직에서는 거의 차이가 없었다. 전자밀도 환산곡선 값의 변화가 선량계산 결과에 미치는 정도를 알아보기 위하여 치료계획장치 상에서 폐조직과 골조직을 포함하는 물 팬톰을 그려서 만들고, 이들 가상 조직의 후방 위치에서 6 MV 광자선에 의한 선량을 계산하였다. 그 결과 폐조직, 물, 골조직의 순서로 선량이 높았으며, 골조직에 의한 선량은 관전압이 낮을수록 높은 값을 보였고, 이는 10 MV의 경우에도 동일하였다. 임상 적용의 예로서 폐 및 골반 부위의 CT 영상을 이용한 선량계산에서는 6 MV 및 10 MV모두 전자밀도 환산곡선 값의 변화에 따른 차이는 없었으며, 전자밀도 환산곡선을 구하는데 이용한 CT 기기와 선량을 계산하는데 이용한 영상을 얻은 CT 기기가 다른 데서 오는 것으로 판단되는 오차로서 최대 1.5%의 상대선량차이를 보였다.

  • PDF

CdTe 멀티에너지 엑스선 영상센서 패키징 기술 개발 (Development of Packaging Technology for CdTe Multi-Energy X-ray Image Sensor)

  • 권영만;김영조;유철우;손현화;김병욱;김영주;최병정;이영춘
    • 한국방사선학회논문지
    • /
    • 제8권7호
    • /
    • pp.371-376
    • /
    • 2014
  • CdTe 멀티에너지 X선 영상센서와 ROIC를 패키징 하기 위한 flip chip bump bonding, Au wire bonding 및 encapsulation 공정조건을 개발하였으며 성공적으로 모듈화 하였다. 최적 flip chip bonding 공정 조건은 접합온도 CdTe 센서 $150^{\circ}C$, ROIC $270^{\circ}C$, 접합압력 24.5N, 접합시간 30s일 때이다. ROIC에 형성된 SnAg bump의 bonding이 용이하도록 CdTe 센서에 비하여 상대적으로 높은 접합온도를 설정하였으며, CdTe센서가 실리콘 센서에 비하여 쉽게 파손되는 것을 고려하여 접합압력을 최소화하였다. 패키징 완료된 CdTe 멀티에너지 X선 모듈의 각각 픽셀들은 단락이나 합선 등의 전기적인 문제점이 없는 것을 X선 3D computed tomography를 통해 확인할 수 있었다. 또한 Flip chip bump bonding후 전단력은 $2.45kgf/mm^2$ 로 측정되었으며, 이는 기준치인 $2kgf/mm^2$ 이상으로 충분한 접합강도를 가짐을 확인하였다.

In vivo 3-dimensional Kinematics of Cubitus Valgus after Non-united Lateral Humeral Condyle Fracture

  • Kim, Eugene;Park, Se-Jin;Lee, Ho-Seok;Park, Jai-Hyung;Park, Jong Kuen;Ha, Sang Hoon;Murase, Tsuyoshi;Sugamoto, Kazuomi
    • Clinics in Shoulder and Elbow
    • /
    • 제21권3호
    • /
    • pp.151-157
    • /
    • 2018
  • Background: Nonunion of lateral humeral condyle fracture causes cubitus valgus deformity. Although corrective osteotomy or osteosynthesis can be considered, there are controversies regarding its treatment. To evaluate elbow joint biomechanics in non-united lateral humeral condyle fractures, we analyzed the motion of elbow joint and pseudo-joint via in vivo three-dimensional (3D) kinematics, using 3D images obtained by computed tomography (CT) scan. Methods: Eight non-united lateral humeral condyle fractures with cubitus valgus and 8 normal elbows were evaluated in this study. CT scan was performed at 3 different elbow positions (full flexion, $90^{\circ}$ flexion and full extension). With bone surface model, 3D elbow motion was reconstructed. We calculated the axis of rotation in both the normal and non-united joints, as well as the rotational movement of the ulno-humeral joint and pseudo-joint of non-united lateral condyle in 3D space from full extension to full flexion. Results: Ulno-humeral joint moved to the varus on the coronal plane during flexion, $25.45^{\circ}$ in the non-united cubitus valgus group and $-2.03^{\circ}$ in normal group, with statistically significant difference. Moreover, it moved to rotate externally on the axial plane $-26.75^{\circ}$ in the non-united cubitus valgus group and $-3.09^{\circ}$ in the normal group, with statistical significance. Movement of the pseudo-joint of fragment of lateral condyle showed irregular pattern. Conclusions: The non-united cubitus valgus group moved to the varus with external rotation during elbow flexion. The pseudo-joint showed a diverse and irregular motion. In vivo 3D motion analysis for the non-united cubitus valgus could be helpful to evaluate its kinematics.

비글견에서 실험적으로 유발한 흉수의 정량 평가: 방사선, 컴퓨터단층촬영 및 초음파 검사 비교 (Quantification of Experimentally Induced-Pleural Effusion in Beagle Dogs: Radiography versus CT and Ultrasonography)

  • 이기자;오이세;정성목;이희천;박성준;이영원;최호정
    • 한국임상수의학회지
    • /
    • 제25권2호
    • /
    • pp.96-101
    • /
    • 2008
  • 흉수량은 흉수천자의 실시 여부 및 진단과 치료에 이용되는 방법의 결정에 영향을 미치므로 흉수량 측정은 중요하다. 본 실험의 목적은 흉수를 정량화하기 위해 흉부 방사선 및 초음파와 컴퓨터단층촬영을 시행하여 그 결과를 비교하고 정확도를 측정하는데 있다. 임상적으로 건강한 6 마리의 비글견을 이용하여 생리식염수를 최종 용량이 60 ml/kg 될 때까지 체중당 10ml씩 흉강에 주입하면서 흉부 방사선 검사, 초음파 검사, CT 검사를 차례로 실시하였다. 흉부 방사선 사진에서 흉수의 유무 평가 및 흉수 정량화를 실시하였으며 초음파 영상에서 흉수량은 폐의 표면과 흉강벽 사이의 최대 수직 거리를 측정하여 평가하였다. CT 영상에서 흉수량은 soft tissue window에서 평가하였으며 최대 흉수량을 나타내는 영상에서 최소 수직거리를 측정하였다. 흉수량과 흉부 방사선 사진 및 초음파 영상에서의 측정치와 통계학적으로 유의적인 결과를 얻지 못했다. 그러나 CT 검사에서의 측정값과 흉수량과의 유의적인 관계를 나타내었다. 특히 흉수의 정량화에서 좌우측 측정치의 평균값이 좌우측 각각의 값보다 더 높은 정확도를 나타내었다. 흉수를 확인하기 위해서는 흉부 방사선 검사 초음파 검사 및 CT 검사가 모두 가능하나 흉수를 정량화하기 위해서는 흉부 방사선 및 초음파 검사보다 CT 검사가 유용함을 확인하였다.