• 제목/요약/키워드: computational fluid dynamics

검색결과 2,896건 처리시간 0.035초

기상 조건과 매립 조건이 비산 먼지 발생에 미치는 영향 (Effects of Meteorological and Reclaiming Conditions on the Reduction of Suspended Particles)

  • 최재원;이영수;김재진
    • 한국환경과학회지
    • /
    • 제19권11호
    • /
    • pp.1423-1436
    • /
    • 2010
  • The effects of meteorological and reclaiming conditions on the reduction of suspended particles are investigated using a computational fluid dynamics (CFD) model with the k-$\varepsilon$ turbulence closure scheme based on the renormalization group (RNG) theory. Twelve numerical experiments with different meteorological and reclaiming conditions are performed. For identifying the meteorological characteristics of the target area and providing the inflow conditions of the CFD model, the observed data from the automatic weather station (AWS) near the target area is analyzed. Complicated flow patterns such as flow distortion, horse-shoe vortex, recirculation zone, and channeling flow appeared due to the topography and buildings in the domain. Specially, the flow characteristics around the reclamation area are affected by the reclaiming height, reclaiming size and windbreak height. Reclaiming height affected the wind speed above the reclaiming area. Windbreak induces more complicated flow patterns around the reclaiming area as well as within the reclaiming area. In front of the windbreak, flow is distorted as it impinges on the windbreak. As a result, upward flow is generated there. Behind the windbreak, a secondary circulation, so called, a recirculation zone is generated and flow is reattached at the end of the recirculation zone (reattachment point). At the lower part of the recirculation zone, there is a reverse flow toward the windbreak. Flow passing to the reattachment point starts to be recovered. Total amounts of suspended particles are calculated using the frictional and threshold frictional velocities, erosion potential function, and the number of surface disturbance. In the case of a 10 m-reclaiming and northerly wind, the amount of suspended particles is largest. In the presence of 5 m windbreak, the friction velocity above the reclaiming area is largely reduced. As a result, the total amount of the suspended particles largely decreases, compared to the case with the same reclaiming and meteorological conditions except for the windbreak The calculated suspended particle amounts are used as the emission rate of the dispersion model simulations and the dispersion characteristics of the suspended particles are analyzed.

풍동실험을 통한 국화군락의 공기유동 저항 분석 (Analysis for Aerodynamic Resistance of Chrysanthemum Canopy through Wind Tunnel Test)

  • 유인호;윤남규;조명환;이인복
    • 생물환경조절학회지
    • /
    • 제17권2호
    • /
    • pp.83-89
    • /
    • 2008
  • 작물은 복잡한 형상 때문에 CFD모델에서 다공성 매체로 설계된다. 작물이 고려된 CFD 모델 해석을 위해서는 작물군락의 공기저항값을 입력하여야 하며, 이 값은 작물에 따라 달라진다. 본 연구에서는 풍동실험을 통해 국화군락의 공기저항 값을 구하였다. 풍상측에서는 풍속과 재식밀도가 증가할수록 정압이 증가하였다. 풍하측에서는 풍속이 증가할수록 정압이 낮아졌으나 재식밀도의 영향은 크게 받지 않는 것으로 나타났다. 풍속과 재식밀도가 증가할수록 풍상측과 풍하측의 압력차가 커지는 것으로 나타났다. 국화군락의 공기저항값인 항력계수 $C_d$값은 0.22였으며, Fluent 프로그램의 공기저항 계수로 이용한다. CFX 프로그램에서 필요로 하는 다공성 매체의 특성값 $K_Q$는 재식간격 $9{\times}9cm$일 때 2.22, $11{\times}11cm$일 때 1.81, $13{\times}13cm$일 때 1.07이었으며, 이 값을 CFX 프로그램의 quadratic resistance coefficient로 입력한다.

HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가 (Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents)

  • 윤철;박진희;황미정;한상훈
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.553-562
    • /
    • 2012
  • 난방, 환기 및 공기조절(HVAC) 기능이 상실된 사고의 경우, 보조급수를 위한 모터-구동 펌프격실의 온도상승을 전산유체역학 분석을 통해 평가하였다. 닫힌 펌프격실의 과도 계산결과, 8 시간 동안 공간-평균된 공기온도는 $60^{\circ}C$ 정도의 상승이 예상된다. 외기 온도 및 외부 온도는 이전 계산결과로부터 초기 $35^{\circ}C$에서 시작하여 서서히 증가한다고 가정하였다. 격실 문이 사고발생 후 약 2, 4, 그리고 6시간 경과 시점에서 열릴 경우, 체적-평균 격실 내가 온도는 약 $4^{\circ}C$의 즉각적인 하강이 나타나며 이후 서서히 온도가 상승하는 장기 거동을 보인다. 전산유체역학을 적용한 현재의 상세 해석결과는 이전의 집중(lumped) 모델을 사용한 보수적인 계산결과에 비해 낮은 격실온도 상승률을 예측한다.

Clark-Y 수중익형 주변 공동 현상에 의한 유동장과 소음 예측에 대한 수치적 연구 (Numerical Study on Cavitation Flow and Noise in the Flow Around a Clark-Y Hydrofoil)

  • 구가람;정철웅;김상현;하콩투;박원규
    • 대한기계학회논문집A
    • /
    • 제41권2호
    • /
    • pp.87-94
    • /
    • 2017
  • 프로펠러와 같은 수중운동체 주변에서 발생하는 공동 현상은 물체를 부식시키고 소음을 발생시키므로, 공학적 측면에서 중요한 문제로 다루어지고 있다. 따라서 본 연구에서는 Clark-Y 수중익형에서 발생하는 공동 현상과 이로 인한 유동 소음을 예측하였다. 공동 예측 결과를 정량적으로는 수중익형 표면의 압력 분포, 정성적으로는 수중익형 주변 공동의 체적분율 변화 양상을 이용하여 비교하였으며, 실험결과 및 선행 연구와 비슷한 경향을 가짐을 확인하였다. 이러한 공동에 의한 유동 소음을 예측하기 위하여 음향상사법을 이용하였으며, 시간에 따른 체적분율 변화를 단극자 소음원으로, 수중 익형 표면에서의 비정상 압력섭동을 이극자 소음원으로 모델링하였다. 소음 예측 결과는 SPL과 방향성을 통해 분석하였고, 계산된 전체 주파수 영역에서 비정상 압력섭동에 의한 소음원이 지배적임을 확인하였다.

탱크 내 격벽에 의한 간극 변화가 선박 운동에 미치는 영향 연구 (A Study of Sloshing Tank on Vessel Motions with Various Baffle Clearance)

  • 김경성;유선진
    • 해양환경안전학회지
    • /
    • 제24권6호
    • /
    • pp.796-802
    • /
    • 2018
  • 선박의 유체 저장 탱크 내부의 적재용량에 의한 선박 운동 고유 특성의 변화는 많은 실험 과 연구를 통해 밝혀졌다. 또한 이러한 현상에 의한 선박 운동 특성 변화를 최소화하기 위한 장치는 지속적으로 연구 및 개발되고 있으며, 특히 횡동요 운동에 대한 저감효과에 대한 부분이 주를 이루고 있다. 본 연구에서는 이러한 장치 중 하나인 저장탱크 내부의 격벽에 의한 횡동요 저감장치의 길이 변화에 따른 간극의 변화에 의한 선박 운동의 변화를 수치 시뮬레이션 하였다. 본 연구를 위해 경계요소법 기반의 부유체 운동 프로그램과 입자법 기반의 전산유체역학 프로그램이 동적 연성된 프로그램을 사용하였으며, 동적 연성된 프로그램은 동일 실험과의 비교를 통해 검증하였다. 검증된 프로그램은 격벽의 길이를 달리하여 간극에 변화를 준 다양한 경우에 대해 수치 시뮬레이션을 수행하였다. 그 결과 액체 저장률의 변화 및 액체 탱크 내부의 격벽에 의한 간극의 차이에 의해 선박 운동 특성이 변화함을 응답 진폭 함수의 비교를 통해 확인하였다. 주목할 만한 결과로써 적재용량에 따라 변화하는 선박의 운동 특성이 간극을 조정함으로써 동일한 선박 특성을 가지게 됨을 확인하였으며, 이는 격벽에 의한 간극의 조종을 통한 선박 운동 제어가 가능함을 보여준다. 추후 격벽의 수 및 각기 다른 길이를 가진 격벽에 의한 연구를 수행하여 격벽 길이 조정을 통한 선박 운동 특성 제어에 대한 연구를 수행할 계획이다.

A study on the action mechanism of internal pressures in straight-cone steel cooling tower under two-way coupling between wind and rain

  • Ke, S.T.;Du, L.Y.;Ge, Y.J.;Yang, Q.;Wang, H.;Tamura, Y.
    • Wind and Structures
    • /
    • 제27권1호
    • /
    • pp.11-27
    • /
    • 2018
  • The straight-cone steel cooling tower is a novel type of structure, which has a distinct aerodynamic distribution on the internal surface of the tower cylinder compared with conventional hyperbolic concrete cooling towers. Especially in the extreme weather conditions of strong wind and heavy rain, heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind, but existing studies mainly focus on the impact effect brought by wind-driven rain to structure surface. In addition, for the indirect air cooled cooling tower, different additional ventilation rate of shutters produces a considerable interference to air movement inside the tower and also to the action mechanism of loads. To solve the problem, a straight-cone steel cooling towerstanding 189 m high and currently being constructed is taken as the research object in this study. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed with continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind sped and rainfall intensity on flow field mechanism, the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower cylinder is analyzed. On this basis, the internal pressures of the cooling tower under the most unfavorable working condition are compared between four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the 3D effect of equivalent internal pressure coefficient is the most significant when considering two-way coupling between wind and rain. Additional load imposed by raindrops on the internal surface of the tower accounts for an extremely small proportion of total wind load, the maximum being only 0.245%. This occurs under the combination of 20 m/s wind velocity and 200 mm/h rainfall intensity. Ventilation rate of shutters not only changes the air movement inside the tower, but also affects the accumulated amount and distribution of raindrops on the internal surface.

초고층 공동주택의 주방.욕실 배기 풍속을 풍력발전에 활용하는 방안 (A Study on the Wind Power Generation Using Vertical Exhaust Air Duct of the High-Rise Apartments)

  • 이용호;김성용;황정하;박진철
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.1-10
    • /
    • 2012
  • The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows: 1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of $0.16m^2{\sim}0.4m^2$. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct/area of PS section ${\times}$ 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01~3.98m/s and contribute to the proper wind velocity level (3.0m/s). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The "entire house holds" condition for exhaust fan operation provided more even exhaust wind velocity than the "some house holds" condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.

지하 열저장 공동의 종횡비와 저장용량에 따른 열성층화 및 열손실 (Thermal Stratification and Heat Loss in Underground Thermal Storage Caverns with Different Aspect Ratios and Storage Volumes)

  • 박도현;류동우;최병희;선우춘;한공창
    • 터널과지하공간
    • /
    • 제23권4호
    • /
    • pp.308-318
    • /
    • 2013
  • 열저장소 내 열성층화는 에너지저장 시스템의 효율을 향상시키고 수요 발생시 더 많은 유효에너지를 공급하기 위해 필수적인 기술이다. 일반적으로 저장소의 종횡비(폭에 대한 높이의 비)와 크기에 따라 열성층도가 달라지는 것으로 알려져 있다. 본 논문은 열수 저장을 위한 암반공동의 종횡비와 저장용량이 저장공동 내 열성층화와 외부로의 열손실에 미치는 영향을 조사하는 데 연구 목적이 있다. 이를 위해 전산유체역학 코드인 FLUENT를 이용하여 암반공동의 종횡비와 저장용량에 따른 열전달 시뮬레이션을 수행하였다. 성층도 정량화 지수를 이용하여 시간경과에 따른 열성층화의 변화를 분석하였으며, 저장공동 외부로의 열손실을 평가하였다. 분석 결과, 종횡비가 증가함에 따라 공동 내 열성층화가 향상되는 경향을 보였으나, 종횡비 3-4 이상부터는 이러한 영향이 크지 않은 것으로 분석되었다. 저장용량이 작은 암반공동에 비해 용량이 큰 암반공동에서 상대적으로 긴 시간 동안 열성층화가 높게 유지되는 것으로 분석되었으나, 종횡비 증가에 따라 저장용량이 다른 공동들간의 성층화 차이가 줄어드는 경향을 나타냈다. 암반공동의 종횡비가 커질수록 공동의 표면적이 늘어나 종횡비의 증가에 따라 주변 암반으로의 열손실이 증가하는 경향을 보였으며, 단위 저장용량을 줄여 소규모 다중공동을 적용하는 경우, 총 저장용량이 동일한 단일공동에 비해 전체 열손실량이 증가하는 것으로 분석되었다.

Practical scaling method for underwater hydrodynamic model test of submarine

  • Moonesun, Mohammad;Mikhailovich, Korol Yuri;Tahvildarzade, Davood;Javadi, Mehran
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1217-1224
    • /
    • 2014
  • This paper provides a practical scaling method to solve an old problem for scaling and developing the speed and resistance of a model to full-scale submarine in fully submerged underwater test. In every experimental test in towing tank, water tunnel and wind tunnel, in the first step, the speed of a model should be scaled to the full-scale vessel (ship or submarine). In the second step, the obtained resistance of the model should be developed. For submarine, there are two modes of movement: surface and submerged mode. There is no matter in surface mode because, according to Froude's law, the ratio of speed of the model to the full-scale vessel is proportional to the square root of lengths (length of the model on the length of the vessel). This leads to a reasonable speed and is not so much for the model that is applicable in the laboratory. The main problem is in submerged mode (fully submerged) that there isn't surface wave effect and therefore, Froude's law couldn't be used. Reynold's similarity is actually impossible to implement because it leads to very high speeds of the model that is impossible in a laboratory and inside the water. According to Reynold's similarity, the ratio of speed of the model to the full-scale vessel is proportional to the ratio of the full-scale length to the model length that leads to a too high speed. This paper proves that there is no need for exact Reynold's similarity because after a special Reynolds, resistance coefficient remains constant. Therefore, there is not compulsion for high speeds of the model. For proving this finding, three groups of results are presented: two cases are based on CFD method, and one case is based on the model test in towing tank. All these three results are presented for three different shapes that can show; this finding is independent of the shapes and geometries. For CFD method, Flow Vision software has been used.

CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구 (The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis)

  • 이성현;유병기;이찬중;임영택
    • 한국버섯학회지
    • /
    • 제15권1호
    • /
    • pp.14-20
    • /
    • 2017
  • 버섯의 단위면적당 생산량을 증대시키기 위하여 다단으로 재배되는 버섯재배사는 재배균상이 내부공기의 유동을 막는 장애물로 작용하여 균상의 아래쪽과 위쪽간의 환경차이가 발생한다. 이러한 환경차이 때문에 버섯재배 균상의 위치에 따른 생육차이가 발생한다. 본 연구에서와 같이 버섯재배사 내부에서 버섯이 생육되지 않는 작업통로의 상단에 천장방향으로 대류팬을 설치하여 운용하면 재배사 내부의 공기를 전체적으로 균일하게 유지할 수 있는 것으로 나타났다. 다만, 버섯재배사 내부에 설치된 각종 환경조절장치 즉 유니트쿨러, 입기팬, 배기팬, 대류팬, 가습기 등이 모두 한꺼번에 가동될 때는 버섯재배 균상위의 RMS 값이 속도 23.86%, 온도 6.08%, 습도 2.72%로 나타났다. 하지만 유니트쿨러와 대류팬이 가동될 때는 균상위의 RMS 값이 속도 23.54%, 온도 0.51%, 습도 0.41%로 나타났다. 따라서 버섯재배사의 환경조절을 위한 입기팬, 배기팬과 가습기는 용량이 큰 것을 설치하여 전체적인 가동시간을 줄이고, 유니트쿨러와 대류팬을 조합한 환경관리 방법이 내부 환경의 균일성 향상에 큰 도움이 될 것으로 판단된다.