• 제목/요약/키워드: compressive ultimate strain

검색결과 145건 처리시간 0.026초

A Study on Residual Compression Behavior of Structural Fiber Reinforced Concrete Exposed to Moderate Temperature Using Digital Image Correlation

  • Srikar, G.;Anand, G.;Prakash, S. Suriya
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.75-85
    • /
    • 2016
  • Fire ranks high among the potential risks faced by most buildings and structures. A full understanding of temperature effects on fiber reinforced concrete is still lacking. This investigation focuses on the study of the residual compressive strength, stress strain behavior and surface cracking of structural polypropylene fiber-reinforced concrete subjected to temperatures up to $300^{\circ}C$. A total of 48 cubes was cast with different fiber dosages and tested under compression after exposing to different temperatures. Concrete cubes with varying macro (structural) fiber dosages were exposed to different temperatures and tested to observe the stress-strain behavior. Digital image correlation, an advanced non-contacting method was used for measuring the strain. Trends in the relative residual strengths with respect to different fiber dosages indicate an improvement up to 15 % in the ultimate compressive strengths at all exposure temperatures. The stress-strain curves show an improvement in post peak behavior with increasing fiber dosage at all exposure temperatures considered in this study.

Mechanical properties of recycled fine glass aggregate concrete under uniaxial loading

  • Liang, Jiong-Feng;Yang, Ze-Ping;Yi, Ping-Hua;Wang, Jian-Bao
    • Computers and Concrete
    • /
    • 제16권2호
    • /
    • pp.275-285
    • /
    • 2015
  • This paper reports the results of an experimental study on the compressive strength and the stress-strain curve (SSC) of recycled fine glass aggregate concrete with different replacement percentages of recycled fine glass aggregate. The results show that the recycled fine glass aggregate contents have significant impact on the workability, compressive strength, the elastic modulus, the peak and the ultimate strains of recycled fine glass aggregate concrete. Analytical expressions for the stress-strain relationship of recycled fine glass aggregate concrete are given, which can satisfactorily describe the effect of the recycled fine glass aggregate on the SSC.

단부 횡보강영역에 따른 전단벽 연성도의 변화 (Variations in Ductility of Shear Wall with Length of Boundary Confinement)

  • 강수민;오재은;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.853-858
    • /
    • 2001
  • Experimental studies were peformed to investigate variations in ductility of shear wall with length of boundary confinement. Eight specimens containg different lengths of confinment zone, which model compressive zone in plastic regions of shear walls, were tested against eccentric vetical load. Stress-strain model for confined concrete was used to predict strength and ductility of the specimens, which was compared to the test results. The results obtained show that failure of the compressive zone occurs in a brittle manner when the stress of unconfined zone softened after the ultimate strength were reached. To enhance the ductility of shear walls with concentrated confinement zone such as barbell-type walls, the ultimate strength of the confinement zone needs to be increased, and for shear walls with distributed confinement zone the length of the confinement zone needs to be extended.

  • PDF

순수 알루미늄의 판재압연 및 공형압연시 가공경로에 따른 변형분포와 기계적 성질의 예측 (Study of the Effect of Loading Path on the Strain and Mechanical Properties of Aluminum with Flat and Groove Rolling Experiment)

  • 김성일;변상민
    • 소성∙가공
    • /
    • 제17권6호
    • /
    • pp.420-428
    • /
    • 2008
  • The effect of loading path changes on the strain and mechanical properties of a commercial pure aluminum was studied using flat rolling and groove rolling. Material during flat rolling undergoes a continuous monotonic compressive loading, while one during groove rolling experiences a series of cross compressive loading. Four-pass flat rolling and groove rolling experiment are designed such that the aluminum undergoes the same amount of the strain at each pass. The rolling experiment was performed at room temperatures. Specimens for tensile test are fabricated from the plate and bar rolled. In addition, the strain distribution for the plate and bar cold rolled specimens is also calculated by finite element method. The results reveal that differences of loading path attributed by monotonic loading(flat rolling) and cross loading(groove rolling) significantly influence the mechanical properties such as yield stress, ultimate tensile stress, strain hardening and elongation. It is clear that the different loading path can give raise to change the deformation history, although it is deformed with same amount of strain for same material.

철근콘크리트 휨부재 설계를 위한 도로교설계기준(한계상태설계법)의 철근비 규정 검토 (Review of Steel ratio Specifications in Korean Highway Bridge Design Code (Limit States Design) for the Design of RC Flexural Members)

  • 이기열;김우;이준석
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.277-287
    • /
    • 2017
  • 이 연구는 한계상태설계법을 기반으로 하는 도로교설계기준에 의해 철근콘크리트 휨부재 설계 시 적용하는 균형철근비와 최대 철근량에 대한 규정을 검토한 것이다. 현행 도로교설계기준(한계상태설계법)에서는 휨부재 철근량 산정의 기준이 되는 균형철근비에 대한 명시적 규정이 없고, 휨모멘트 재분배 효과를 반영한 최대 중립축 깊이 및 콘크리트 단면적의 0.04배로서 최대 철근량을 산정한다. 그런데, 최대 중립축 깊이 규정에 의하면 최대 철근량이 적게 산정되어 단면을 크게 하여야 하며, 콘크리트 단면적의 0.04배라는 한계값이 적용될 경우에는 인장 철근의 변형률이 항복 변형률의 2배 이하로 되어 충분한 연성거동을 보장할 수 없는 문제점이 있다. 이 연구에서는 연성거동을 확보할 수 있는 휨부재 설계를 위한 사용 철근량 산정의 기준이 되는 균형철근비를 극한한계상태 검증 규정 및 재료 특성과 콘크리트 기준압축강도에 따른 극한한계변형률을 도입하여 설계 실무에 적용할 수 있도록 간편한 식으로 유도하였다. 그리고, 설계된 휨부재가 충분한 연성이 확보되도록 인장철근의 최소허용변형률을 항복변형률의 2배로 가정하고 철근의 기준항복강도 및 콘크리트 기준압축강도에 상관없이 만족할 수 있도록 최대 중립축 깊이 비 보정계수를 도입하여 수정하고, 이로부터 최대철근비를 산정할 수 있도록 하였다.

Behavior of polygonal concrete-filled steel tubular stub columns under axial loading

  • Zhang, Tao;Ding, Fa-xing;Wang, Liping;Liu, Xue-mei;Jiang, Guo-shuai
    • Steel and Composite Structures
    • /
    • 제28권5호
    • /
    • pp.573-588
    • /
    • 2018
  • The objective of this paper is to investigate the mechanical performances of polygonal concrete-filled circular steel tubular (CFT) stub columns under axial loading through combined experimental and numerical study. A total of 32 specimens were designed to investigate the effect of the concrete strength and steel ratio on the compressive behavior of polygonal CFT stub columns. The ultimate bearing capacity, ductility and confinement effect were analyzed based on the experimental results and the failure modes were discussed in detail. Besides, ABAQUS was adopted to establish the three dimensional FE model. The composite action between the core concrete and steel tube was further discussed and clarified. It was found that the behavior of CFT stub column changes with the change of the cross-section, and the change is continuous. Finally, based on both experimental and numerical results, a unified formula was developed to estimate the ultimate bearing capacity of polygonal CFT stub columns according to the superposition principle with rational simplification. The predicted results showed satisfactory agreement with both experimental and FE results.

Strain penetration of high-strength steel bars anchored in reinforced concrete beam-column connections

  • Li, Ling;Zheng, Wenzhong;Wang, Ying
    • Structural Engineering and Mechanics
    • /
    • 제72권3호
    • /
    • pp.367-382
    • /
    • 2019
  • This paper presents experimental and analytical investigations on additional fixed-end rotations resulting from the strain penetration of high-strength reinforcement in reinforced concrete (RC) beam-column connections under monotonic loading. The experimental part included the test of 18 interior beam-column connections with straight long steel bars and 24 exterior beam-column connections with hooked and headed steel bars. Rebar strains along the anchorage length were recorded at the yielding and ultimate states. Furthermore, a numerical program was developed to study the effect of strain penetration in beam-column connections. The numerical results showed good agreement with the test results. Finally, 87 simulated specimens were designed with various parameters based on the test specimens. The effect of concrete compressive strength ($f_c$), yield strength ($f_y$), diameter ($d_b$), and anchorage length ($l_{ah}$) of the reinforcement in the beam-column connection was examined through a parametric study. The results indicated that additional fixed-end rotations increased with a decrease in $f_c$ and an increase in $f_y$, $d_b$ and $l_{ah}$. Moreover, the growth rate of additional fixed-end rotations at the yielding state was faster than that at the ultimate state when high-strength steel bars were used.

Low strength concrete members externally confined with FRP sheets

  • Ilki, Alper;Kumbasar, Nahit;Koc, Volkan
    • Structural Engineering and Mechanics
    • /
    • 제18권2호
    • /
    • pp.167-194
    • /
    • 2004
  • In this paper axial loading tests on low strength concrete members, which were confined with various thickness of carbon fiber reinforced polymer (CFRP) composite sheets are described. Totally 46 specimens with circular, square and rectangular cross-sections with unconfined concrete compressive strengths between 6 and 10 MPa were included in the test program. During the tests, a photogrammetrical deformation measurement technique was also used, as well as conventional measurement techniques. The contribution of external confinement with CFRP composite sheets to the compressive behavior of the specimens with low strength concrete is evaluated quantitatively, in terms of strength, longitudinal and lateral deformability and energy dissipation. The effects of width/depth ratios and the corner radius of the specimens with rectangular cross-section on the axial behavior were also examined. It was seen that the effectiveness of the external confinement with CFRP composite sheets is much more pronounced, when the unconfined concrete compressive strength is relatively lower. It was also found that the available analytical expressions proposed for normal or high strength concrete confined by CFRP sheets could not predict the strength and deformability of CFRP confined low strength concrete accurately. New expressions are proposed for the compressive strength and the ultimate axial strain of CFRP confined low strength concrete.

콘크리트의 변형률 국소화에 관한 연구 (A Study on the Strain Localization of Concrete)

  • 서철;변근주;송하원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.178-182
    • /
    • 1995
  • Strain localization is important phenomenon since it governs the total behavior or ultimate loads in various kinds of engineering problems. Establishment of an analysis method for strain localization phenomena is also of great concern for expansion of fracture mechanics of concrete. Inside zone of localization, a decrese in stress is accompanied by an increse in strain; outside the strain decreses. All deformation localization phenomenon cannot be predicted by both the classical stress-strain formulation and the linear elastic fracture mechanics. In this paper, a simple one dimensional model including localized deformation zone is studied under compressive and tensile loading. When the model is loaded. localization is assumed to occur uniformly in a finite region and material outside the localization zone is modelled as elastic unloading occurs. Size effects of effective elastic moduli under compression and tension in localization zone are examined.

  • PDF

용접철망을 사용한 슬래브접합부의 구조성능에 관한 실험적 연구 (An Experimental Study on the Structural Performance of Slab Joint Using Welded Wire Fabric)

  • 윤영호;양지수;김석중;정란;양영성;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.291-300
    • /
    • 1994
  • The influence of elevated temperatures on the mechanical properties of concrete is important for fire-resistance studies and also for understanding the behavior of containment vessel, such as nuclear reactor pressure vessels, during service and ultimate condition. The present study is to clarify the damage/deterioration of concrete structures that are subjected to high temperature exposure. To this end, comprehensive experiments are conducted. The major test variables are the peak temperatures, rate of temperature increase, and sustained duration at peak temperature. The results include weight loss residual compressive strength and stress-strain curve. From those results, residua compressive strength formula and stress-strain relationship are proposed.

  • PDF