• Title/Summary/Keyword: compressed pulse

Search Result 48, Processing Time 0.023 seconds

Optimal Radar Pulse Compression Processing Algorithm and the Resulting Optimal Codes for Pulse Compressed Signals (레이더 펄스 압축 신호의 최적 탐색 알고리즘 개발 및 최적 코드에 관한 연구)

  • 김효준;이명수;김영기;송문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.6B
    • /
    • pp.1100-1105
    • /
    • 2000
  • The most widely used radar pulse compression technique is correlation processing using Barker code. This technique enhances detection sensitivity but, unfortunately, suffers from the addition of range sidelobes which sometimes will degrade the performance of radar systems. In this paper, our proposed optimal algorithm eliminates the sidelobes at the cost of additional processing and is evaluated in the presence of Doppler shift. We then propose optimal codes with regard to the proposed algorithm and the performance is compared against the traditional correlation processing with Barker codes. The proposed processing using optimal codes will be shown to be superior over the traditional processing in the presence of Doppler shift.

  • PDF

Midinfrared Pulse Compression in a Dispersion-decreasing and Nonlinearity-increasing Tapered As2S3 Photonic Crystal Fiber

  • Shen, Jianping;Zhang, Siwei;Wang, Wei;Li, Shuguang;Zhang, Song;Wang, Yujun
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.250-260
    • /
    • 2021
  • A tapered As2S3 photonic crystal fiber (PCF) with four layers of air holes in a hexagonal array around the core is designed in this paper. Numerical simulation shows that the dispersion D decreases and the nonlinearity coefficient γ increases from the thick to the thin end along the tapered PCF. We simulate the midinfrared pulse compression in the tapered As2S3 PCF using the adaptive split-step Fourier method. Initial Gaussian pulses of 4.4 ps and a central wavelength of 2.5 ㎛ propagating in the tapered PCF are located in the anomalous dispersion region. With an average power of assumed input pulses at 3 mW and a repetition frequency of 81.0 MHz, we theoretically obtain a pulse duration of 56 fs and a compression factor of 78 when the pulse propagates from the thick end to the thin end of the tapered PCF. When confinement loss in the tapered PCF is included in the simulation, the minimum pulse duration reaches 72 fs; correspondingly, the maximum compression factor reaches 61. The results show that in the anomalous-dispersion region, midinfrared pulses can be efficiently compressed in a dispersion-decreasing and nonlinearity-increasing tapered As2S3 PCF. Due to confinement loss in the tapered fiber, the efficiency of pulse compression is suppressed.

Optical Pulse Compression at $1.319{\mu}m$ Through Fiber-grating Pair (광섬유와 회절격자를 이용한 $1.319{\mu}m$ 파장 광펄스의 압축)

  • 이재승;박희갑;심창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.13-19
    • /
    • 1991
  • Utilizing self-phase modulation effects of a dispersion-shifted fiber and delayline characteristics of two gratings, mode-locked 80 ps pulses at 1.319 $\mu \textrm m$ wavelength from a Nd:YAG laser are compressed to 2.1 ps. This experiment is suitable for studying the transmission characteristics of high energy short pulses along normal fibers in zero dispersion regime.

  • PDF

A Study on parameter optimization and output stabilization of Magnetic Switch System. (자기스위치 시스템의 파라메다 최적화 및 출력 안정화에 관한 연구)

  • Jun, Sang-Young;Lee, Choo-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.637-641
    • /
    • 1989
  • We have developed 3-stage of Magnetic Switch System based on the nonlinearities of ferromagnetic material used in the saturable inductor, and made experiment of parameter optimization and output stabilization of Magnetic Switch System. The cross-section and conductor burns of each satarable inductor were optimized 30 $cm^2$ 19.25 $cm^2$ 5, and 25 $cm^2$ 2, respectively. With this condition, 6.2 us [FWHM], 96 A pulse at first stage was compressed into 0.4 us[FWHM], 1.61 kA pulse at last stage. The current gain and compression ratio were 16.8, 17, respectively. ln addition, System output was stabilized with reset current of 6 A, 200 us.

  • PDF

A Study on the Breakdown Mechanism of Compressed $SF_6$ by Polarity of a Protrusion on Electrode Surface (전극표면상 미소돌기의 극성에 의한 압축 $SF_6$ 개스의 절연파괴 Mechanism에 관한 연구)

  • 이동인;이광식;김인식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.956-963
    • /
    • 1990
  • The general shapes of prebreakdown pulses in a discharge gap were calculated and the current pulses due to avalanche were detected in SF6 by changing the polarity of the protrusion placed on an electrode at pressures up to about 400 Kpa. The mathematical model of prebreakdown pulse development with a negative protrusion shows agreement with the observed pulses. No evidence of intense bursts of field-emitted electrons was observed. Breakdown probably results from a single avalanche developing to a critical size. However the calculated shape of prebreakdown current pulse does not agree with the observed pulses with a positive protrusion. The breakdown is preceded by multiple avalanche development at pressures less than about 200 Kpa. This observation has been interpreted as due to the formation of negative ions following photoionization in the gas which drift into the critical volume near a positive protrusion.

  • PDF

An implementation of 60W X-band Cascade SSPA for Marine Radar System (선박 레이다용 60W X-band Cascade SSPA 구현)

  • Kim, Min-Soo;Jang, Yeon-Gil;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, An X-band solid state power amplifier(SSPA) for pulse compressed microwave signal with 60Watt power and power added efficiency(PAE) above 30% is described. Designed 60Watt high power amplifier(HPA) was implemented by cascade coupled amplifiers, and it is consisted on three stage drive amplifiers with internally matched GaAs FET and one stage main power amplifier with an internally matched GaN HEMT. The designed SSPA has performance with more than total power gain 37dB and output power 48dBm(60-W) in condition of frequency range $9.41{\pm}0.03GHz$, pulse period width under 1ms and duty cycle under 10%. The implemented SSPA can apply to high quality digital marine radar applications with pulse compression technique.

High Power Laser Driven Shock Compression of Metals and Its Innovative Applications (고 출력 레이저에 의한 충격파 현상 연구 및 응용)

  • Lee, Hyun-Hee;Gwak, Min-Cheol;Choi, Ji-Hee;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.832-840
    • /
    • 2008
  • Ablation occurs at irradiance beyond $10^9\;W/cm^2$ with nanosecond and short laser pulses focused onto any materials. Phenomenologically, the surface temperature is instantaneously heated past its vaporization temperature. Before the surface layer is able to vaporize, underlying material will reach its vaporization temperature. Temperature and pressure of the underlying material are raised beyond their critical values, causing the surface to explode. The pressure over the irradiated surface from the recoil of vaporized material can be as high as $10^5\;MPa$. The interaction of high power nanosecond laser with a thin metal in air has been investigated. The nanosecond pulse laser beam in atmosphere generates intensive explosions of the materials. The explosive ejection of materials make the surrounding gas compressed, which form a shock wave that travels at several thousand meters per second. To understand the laser ablation mechanism including the heating and ionization of the metal after lasing, the temporal evolution of shock waves is captured on an ICCD camera through laser flash shadowgraphy. The expansion of shock wave in atmosphere was found to agree with the Sedov's self-similar spherical blast wave solution.

Simultaneous Multiple Transmit Focusing Using Orthogonal Weighted Linear FM Chirp (가중된 직교 선형 FM신호를 이용한 송신 동시 다중 빔집속 기반의 초음파 영상 기법)

  • 정영관;송태경
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.155-158
    • /
    • 2001
  • A new method for simultaneous multiple transmit focusing using orthogonal weighted FM chirp is proposed. Weighted chirp signals focused at different depths are transmitted at the same time. These chirp signals are mutually orthogonal in the approximate sense that the autocorrelation function of each signal has a narrow mainlobe width and low sidelobe levels, and the crosscorrellation function of any pair of the signals has smaller values than the sidelobe levels of each autocorrelation function. This means that each weighted chirp signal can be separately compressed into a short pulse, focused individually and combined with other focused beams to form a frame of image. Theoretically, any two chirp signals defined in two nonoverlapped frequency bands are mutually orthogonal. In the present work, however, a fractional overlap of adjacent frequency bands, by up to 25%, were permitted to design more chirp signals within a given transducer bandwidth. The crosscorrelation values due to the frequency overlap could be reduced by alternating the direction of frequency sweep of the adjacent chirp signals. The simulation results show that this method can improve the lateral resolution of image without sacrifice in the frame rate compared with the conventional pulse system.

  • PDF

Experimental Studies on the interaction of Kangsimsan and Hydralazine, Verapamil, Clonidine, Hydrochlorothiazide and Furosemide (고혈압(高血壓)에 강심산(强心散)과 Hydralazine, Clonidine, Hydrochlorothiazide 및 Furosemide의 병용투여(倂用投與)에 관한 실험적(實驗的) 연구(硏究))

  • Kim, Jin-Don;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.198-211
    • /
    • 1994
  • After giuing some anti-high blood pressure medicine of boiled-compressed fluid and 5-Kinds factors(Hydralazine, Verapamil, Clonidine, Furosemide and Hydrochlorothiazide with Kangsimsan to animals in single or together. I got the following conclusion in comparing blood-pressure and pulse of circulating system with urinating operation. 1. By joint-use of Kangsimsan and Hydralazine. it was found out that the effect of blood-pressure lowering continues longer in together-use than in single. And I coule see that the number of pulse increased. 2. By joint-use of Kangsimsan and Verapamil. the blood-pressure lowering operation was kept better in together-use than in single. the number of pulse was not affected any. 3. By joint-use of Kangsimsan and Clonidine the blood-pressure lowering operation was not found out any concrete result. 4. By joint-use of Kangsimsan and Furosemide. the Remarkble effect of Urinization was recognized to be much better in joint-use than in single. 5. By joint-use of Kangsimsan and Hydrochlorothiazide. the suppressing effect of urinization was recognized to be much better in joint-use than in single. Therefore in consideration of the above study and observation. when the joint-use of Kangsimsan and the blood-pressure lowering medicine. Hydralazine and Verapamil. the period of blood-pressure lowering was kept and I can conclude that in case of joint-use of Furosemide, a kind of good urinization. the effect of urinization by Furosemide is increased, but that of Hydrochlorothiazide is disturbed.

  • PDF

Design of FPGA-based Signal Processing of EWRG for Localized Heavy Rainfall Observation (국지성 호우 관측을 위한 FPGA 기반의 전파강수계 신호처리 설계)

  • Choi, Jeong-Ho;Lee, Bae-Kyu;Park, Hyeong-Sam;Park, Jeong-Min;Lim, Sang-Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1215-1223
    • /
    • 2020
  • Recently, the number of natural disasters caused by inclement weather conditions such as localized heavy rainfall, Typhoon, etc. is increasing in Korea, which requires relevant prevention and water management measures. Rain gauges installed on the ground have strengths in continuously·directly measures ground precipitation but cannot provide accurate information on spatial precipitation distribution in the areas without the rain gauges. The present research has designed and developed an electromagnetic-based multi-purpose precipitation gauge(EWRG, Electromagnetic Wave Rain Gauge) that can measure rainfall at the real time, by overcoming spatial representativeness. In this paper, we propose an FPGA-based signal processing design method for EWRG. The signal processing of the EWRG was largely designed by calculating the ADC and DDC of the LFM waveform, pulse compression, correlation coefficient and estimating the precipitation parameter. In this study, the LFM waveform and pulse compressed signal were theoretically analyzed.