• Title/Summary/Keyword: compound eye

Search Result 68, Processing Time 0.026 seconds

Shortwave Infrared Photodetector based on PbS Quantum Dots for Eye-Safety Lidar Sensors (Eye safety 라이다 센서용 황화납 양자점 기반 SWIR photodetector 개발)

  • Suji Choi;JinBeom Kwon;Yuntae Ha;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.285-289
    • /
    • 2023
  • Recently, the demand for lidar systems for autonomous driving is increasing, and research on Shortwave Infrared(SWIR) photodetectors for this purpose is being actively conducted. Most SWIR photodetectors currently being developed are based on InGaAs, and have the disadvantages of complex processes, high prices, and limitations in research due to monopoly. In addition, current SWIR photodetectors use lasers in the 905 nm wavelength band, which can pass through the pupil and cause damage to the retina. Therefore, it is required to develop a SWIR photodetector using a wavelength band of 1400 nm or more to be safe for human eyes, and to develop a material that can replace the proprietary InGaAs. PbS QDs are group 4-6 compound semiconductors whose absorption wavelength band can be adjusted from 1000 to 2700 nm, and have the advantage of being simple to process. Therefore, in this study, PbS QDs having an absorption wavelength peak of 1415 nm were synthesized, and a SWIR photodetector was fabricated using this. In addition, the photodetector's responsivity was improved by applying P3HT and ZnO NPs to improve electron hole mobility. As a result of the experiment, it was confirmed that the synthesized PbS QDs had excellent FWHM characteristics compared to commercial PbS QDs, and it was confirmed that the photodetector had a maximum current change of about 1.6 times.

Discrimination Method of Brown Planthopper, Nilaparvata lugens(Stal) Nymphs by the Fluorescent Spots between Compound Eyes in Rice Paddies (벼논에서 벼멸구(Nilaparvata lugens Stal)약충 두부의 형광성 반점에 의한 식별법)

  • 조성래;이동운;추호렬;박정규;신현열;김형환
    • Korean journal of applied entomology
    • /
    • v.42 no.4
    • /
    • pp.361-365
    • /
    • 2003
  • Several species of planthoppers such as brown planthopper, N. lugens (Stal) (BPH), smaller brown planthopper, Laodelphax striatellus (Fall n) (SBPH), and white-backed planthopper, Sogatella furcifera (Horv th) (WBPH) are distributed in Korean rice paddies but not easy to discriminate them in situ. Accurate discrimination of them is an indispensable process in the forecasting for their outbreak and control. Especially, innovative discrimination method for BPH was required because BPH was one of the most important insect pest of rice. Nymphs and adults of BPHs, SBPHS, and WBPHS, thus, were examined their morphological characteristics in the paddies and laboratory. The nymphs of BPH had different characters from those of SBPH and WBPH. The nymphs of BPH had white fluorescent spot between bottom of compound eye and antenna, while there was no that spot the other two species. The white spot was the brightest at the nymphs just after hatching and getting weaker as the nymph developed. At last the white spot was totally disappeared at the adult stage. This white spot was innovative criterium to discriminate nymphs of BPH, SBPH, and WBPH in rice paddies.

Survey on the Refractive Status of Primary School Children with Subnormal Visual Acuity in Seoul (서울지역 초등학동 비정시안의 굴절상태에 대한 조사)

  • Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.65-69
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. This study was researched visual acuity test using objective and subjective methods. 1. The eye types were 90.3% positive for myopia, 3.1% for emmetropia, 4.9% hyperopia, 1.7% for mired astigmatism. 2. The abnormal refraction eyes were 58.6% positive for simple myopia, 29.9% for myopic compound astigmatism, 5.1% for my optic simple astigmatism and 1.9% for simple hyperopia, 1.9% for hyperopic compound astigmatism, 1.3% for hyperopic simple astigmatism, 1.3% for mixed astigmatism. 3. The axis of astigmatism were 85.7% for astigmatism with-the-rule, 9.3% for astigmatism against-the-rule, 5.0% for astigmatism oblique. 4. On total myopic spheric power. the -0.50

  • PDF

Eyes and Vision of the Bumblebee: a Brief Review on how Bumblebees Detect and Perceive Flowers

  • Meyer-Rochow, V.B.
    • Journal of Apiculture
    • /
    • v.34 no.2
    • /
    • pp.107-115
    • /
    • 2019
  • Bumblebees have apposition compound eyes (one on either side of the head) of about 6,000 ommatidia and three small single-lens ocelli on the frons of their head capsule. The surface of the eye is smooth and interommatidial hairs, as in the honeybee, are not developed. Each ommatidium (approx. 26 ㎛ in diameter) is capped by a hexagonal facet and contains in its centre a 3 ㎛ wide, columnar light-perceiving structure known as the rhabdom. Rhabdoms consist of thousands of regularly aligned, fingerlike microvilli, which in their membranes contain the photopigment molecules. Axons from each ommatidium transmit the information of their photic environment to the visual centres of the brain, where behavioural reactions may be initiated. Since bumblebee eyes possess three classes of spectrally different sensitivity peaks in a ratio of 1:1:6 (UV= 353 nm, blue= 430 nm and green=548 nm) per ommatidium, they use colour vision to find and select flower types that yield pollen and nectar. Ommatidial acceptance angles of at least 3° are used by the bumblebees to discriminate between different flower shapes and sizes, but their ability to detect polarized light appears to be used only for navigational purposes. A flicker fusion frequency of around 110Hz helps the fast flying bumblebee to avoid obstacles. The small ocelli are strongly sensitive to ultraviolet radiation and green wavelengths and appear to act as sensors for light levels akin to a photometer. Unlike the bumblebee's compound eyes, the ocelli would, however, be incapable of forming a useful image.

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

A Study of Eye Refraction State on Male Old Age (노인 남성의 안굴절 상태에 대한 연구)

  • Yoo, Jae Tae;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.21-25
    • /
    • 2000
  • The old age may experienced the visual acuity decrease according to refraction abnormality and they have a inconvenient real life style on viewing condition. So that, This study can provide the accurate information on the treatment of visual acuity of a male old ages by test of eye refraction state. The test was performed the visual acuity test by the object and subject methods.and the subjects was the Korean male over 55 old age. The eye types were 0.8 % positive for emmetropia, 15.2 % for myopia, and 84 % for hyperopia, respectively. The abnormal refraction eyes were 1.3 % positive for simple myopic astigmatism, 13.9 % for compound myopic astigmatism. 3.4 % for simple hyperopia and 3.1 % for simple hyperopic astigmatism, 77.5 % for mixed astigmatism, respectively. The asix of astigmatisms were 62% positive for against-the-rule astigmatism, 6% for with-the rule astigmatism, and 32 % for oblique astigmatism, respectively. On the total myopic spherical power, the $-0.50{\leq}$spheric equivalent <-2.00 diopter was 84.3%, the $-2.00{\leq}$spherical equivalent <-6.00.diopter was 15.7%. On the total hyperopic spherical power, the $+0.50{\leq}$spheric equivalent <+2.00 diopter was 74.2%, the $+2.00{\leq}$spherical equivalent <+6.00 diopter was 24.8%, and anything over the +6.00 diopter was 1%. On the astigmatic power, the $0.5{\leq}$cylinder <1.00 diopter was 54.1%, the $1.00{\leq}$cylinder <2.00 diopter was 32.4%, and anything over the 2.00 cylinder diopter was 13.5%.

  • PDF

Research about the Distribution of Refractive Errors in Distinction of Gender and at Age of Kyonggi Province's Part Area (경기도 일부지역의 성별, 연령별 굴절이상 분포에 관한 연구)

  • Lee, Eun-Hee;Lee, Hee-Jung;Cho, Sung-Il;Paek, Do-Myung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.2
    • /
    • pp.121-129
    • /
    • 2006
  • Prevalence of refractive error have revealed variation in relation to ethnicity, educational level, age, gender, and social economic status. Especially prevalence of refractive error varies by country, estimation of prevalence of refractive error have shown increase in Asia than in Western world. The present report aimed to investigate the prevalence of refractive errors by the age and gender in Korean population without eye disease. A total of 960 subjects were sampled and their refractive error was determined using Auto refractometer. Prevalence of emmetropia was 29% and that for myopia and hyperopia was 67%, 4%, respectively. Astigmatism was 22%, and the simple astigmatism was 1%. However the compound astigmatism was 99%. Prevalence of refractive errors differed significantly among age and gender group in our results. The percentages of with-the-rule, against-the-rule and oblique astigmatism among people with astigmatism were 36.6%, 20.7% and 42.7% for right eye and 31.8%, 10% and 58.1% for left eye.

  • PDF

Estimation of Genetic Parameters for Characterization of Carcass Traits and Fatty Acid in Hanwoo (한우 등심의 지방산 유전특성 분석을 위한 유전모수 추정)

  • Kim, Hyeon Kwon;Sun, Du Won;Joo, Seon tae;Lee, Jung Gyu
    • Journal of agriculture & life science
    • /
    • v.53 no.4
    • /
    • pp.55-59
    • /
    • 2019
  • Hanwoo has improved the quality of carcass traits. Especially, the higher the grade, the better the texture and taste of Hanwoo. One of the many factors that determine consumer preferences in food is the flavor. The flavor of food is expressed through heat treatment, and fat, carbohydrate and water-soluble compound are important ingredients for flavor. Therefore, The purpose of this study was to investigate the characteristics of fatty acids and carcass traits of 373 Hanwoos. The oleic acid (C18:1) and linolenic acid (C18:3) contents were 48.08% and 0.11%, respectively, while the carcass weight, Eye muscle area, back fat thickness and marbling score of the carcass trait were 383.73 kg, 83.88 ㎠, 10.91 mm, 3.89, respectively. The heritability of oleic acid was estimated to be 0.726, and the phenotypic correlation between eye muscle area and marbling score was estimated to be 0.105 and 0.141, respectively. The phenotype of the marbling score and eye muscle area were positively correlated with Oleic acid. Therefore, the improvement of these two traits seems to affect the increase of unsaturated fatty acid content.

Safe Sedation and Hypnosis using Dexmedetomidine for Minimally Invasive Spine Surgery in a Prone Position

  • Kim, Kyung Hoon
    • The Korean Journal of Pain
    • /
    • v.27 no.4
    • /
    • pp.313-320
    • /
    • 2014
  • Dexmedetomidine, an imidazoline compound, is a highly selective ${\alpha}_2$-adrenoceptor agonist with sympatholytic, sedative, amnestic, and analgesic properties. In order to minimize the patients' pain and anxiety during minimally invasive spine surgery (MISS) when compared to conventional surgery under general anesthesia, an adequate conscious sedation (CS) or monitored anesthetic care (MAC) should be provided. Commonly used intravenous sedatives and hypnotics, such as midazolam and propofol, are not suitable for operations in a prone position due to undesired respiratory depression. Dexmedetomidine converges on an endogenous non-rapid eye movement (NREM) sleep-promoting pathway to exert its sedative effects. The great merit of dexmedetomidine for CS or MAC is the ability of the operator to recognize nerve damage during percutaneous endoscopic lumbar discectomy, a representative MISS. However, there are 2 shortcomings for dexmedetomidine in MISS: hypotension/bradycardia and delayed emergence. Its hypotension/bradycardiac effects can be prevented by ketamine intraoperatively. Using atipamezole (an ${\alpha}_2$-adrenoceptor antagonist) might allow doctors to control the rate of recovery from procedural sedation in the future. MAC, with other analgesics such as ketorolac and opioids, creates ideal conditions for MISS. In conclusion, dexmedetomidine provides a favorable surgical condition in patients receiving MISS in a prone position due to its unique properties of conscious sedation followed by unconscious hypnosis with analgesia. However, no respiratory depression occurs based on the dexmedetomidine-related endogenous sleep pathways involves the inhibition of the locus coeruleus in the pons, which facilitates VLPO firing in the anterior hypothalamus.

Trends in Biomimetic Vision Sensor Technology (생체모방 시각센서 기술동향)

  • Lee, Tae-Jae;Park, Yun-Jae;Koo, Kyo-In;Seo, Jong-Mo;Cho, Dong-Il Dan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.12
    • /
    • pp.1178-1184
    • /
    • 2015
  • In conventional robotics, charge-coupled device (CCD) and complementary metal-oxide-semiconductor (CMOS) cameras have been utilized for acquiring vision information. These devices have problems, such as narrow optic angles and inefficiencies in visual information processing. Recently, biomimetic vision sensors for robotic applications have been receiving much attention. These sensors are more efficient than conventional vision sensors in terms of the optic angle, power consumption, dynamic range, and redundancy suppression. This paper presents recent research trends on biomimetic vision sensors and discusses future directions.