• Title/Summary/Keyword: composite resins

Search Result 447, Processing Time 0.04 seconds

Dental Restorative Composite Resins Containing Asymmetric Spiro Orthocarbonate for the Reduction of Volumetric Shrinkage (비대칭 스파이로 오르토카보네이트가 포함된 저수축 치아 수복재)

  • 황미선;김창근
    • Polymer(Korea)
    • /
    • v.28 no.4
    • /
    • pp.321-327
    • /
    • 2004
  • The applications of dental restorative composite resins containing 2,2-bis [4-(2-hydroxy-3-me-thacryloyloxy propoxy) phenyl] propane as a base resin, and triethylene glycol dimethacrylate, as a diluent, were often limited in dentistry due to the relatively large amount of volumetric shrinkage that occurs during the curing reaction. In this study, in order to reduce volumetric shrinkage of the current dental restorative composite resin, asymmetric spiro orthocarbonates were synthesized and then the characteristics of resin composites containing them were explored. The volumetric shrinkage of the dental composites containing spiro orthocarbonates was decreased approximately 45%. However, the curing characteristics and mechanical properties of the new dental composites were slightly poor than those of the commercially available dental composite.

Mechanical properties of composite resins for dental restorative (치과 수복재용 복합레진의 기계적 물성에 대한 연구)

  • Ryu, Ho-Nam;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.35
    • /
    • pp.31-34
    • /
    • 2015
  • The purpose of the study was to investigate the mechanical properties (diametral tensile strength, flexural strength, compressive strength, Vickers hardness) of 4 kinds of composit resins; Bis-GMA based composit, Bis-EMA based composit, Bis-GMA/UDMA based composit, and Bis-EMA/UDMA based composit, The composit resin based Bis-GMA showed stronger mechanical properties than Bis-EMA. It was found that the addition of UDMA to both Bis-GMA based composit and Bis-EMA based composit highly improved mechanical properties. However, the mechanical properties of the composit resins prepared in this study were lower than those of the commercialized products in market(Charmfil flow(Denkist), Quadrant flow(CAVEX)), since the composit resins prepared in this study has much lower inorganic filler content of 43wt% comparing with 50~70wt% inorganic filler content of the commercialized products.

  • PDF

THE POLYMERIZATION RATE AND THE DEGREE OF CONVERSION OF COMPOSITE RESINS BY DIFFERENT LIGHT SOURCES (광원의 종류에 따른 복합레진의 중합거동 및 중합률에 관한 연구)

  • Ryoo, Joo-Hee;Lee, In-Bog;Yoo, Hyun-Mee;Kim, Mi-Ja;Seok, Chang-In;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.386-398
    • /
    • 2004
  • Objectives: The purpose of this study was to observe the reaction kinetics and the degree of polymerization of composite resins when cured by different light sources and to evaluate the effectiveness of the blue Light Emitting Diode Light Curing Units (LED LCUs) compared with conventional halogen LCUs. Materials and Methods: First, thermal analysis was performed by a differential scanning calorimeter (DSC). The LED LCU (Elipar Freelight, $320{\;}mW/\textrm{cm}^2$) and the conventional halogen LCU (XL3000, $400{\;}mV/\textrm{cm}^2$) were used in this study for curing three composite resins (SureFil, Z-250 and AEliteFLO). Second. the degree of conversion was obtained in the composite resins cured according to the above curing mode with a FTIR. Third, the measurements of depth of cure were carried out in accordance with ISO 4049 standards. Statistical analysis was performed by two-way ANOVA test at 95% levels of confidence and Duncan's procedure for multiple comparisons. Results: The heat of cure was not statistically different among the LCUs (p > 0.05). The composites cured by the LED (Exp) LCUs were statistically more slowly polymerized than by the halogen LCU and the LED (Std) LCU (p < 0.05). The composite resin groups cured by the LED (Exp) LCUs had significantly greater degree of conversion value than by the halogen LCU and the LED (Std) LCU (p =0.0002). The composite resin groups cured by the LED (Std) LCUs showed significantly greater depth of cure value than by the halogen LCU and the LED (Exp) LCU (p < 0.05).

Effect of Immersion in Water and Thermal Cycling on the Mechanical Properties of Light-cured Composite Resins (광중합형 수복용 복합레진의 기계적 성질에 미치는 수중침적과 Thermal Cycling의 영향)

  • Bae, Tae-Sung;Kim, Tae-Jo;Kim, Hyo-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.327-336
    • /
    • 1996
  • This study was performed to investigate the effec% of immersion in water and thermal cycling on the mechanical peoperties of light cured restorative composite resins. Five commerically available light-cured composite resins(Photo Clearfil A : CA, Lite-Fil A . LF, Clearril Photo Posterior CP, Prisms AP.H.. PA, 2100 : ZH) were unto The specimens of 12 m in diameter and 0.7 m in thickness were made, and an immersion in $37^{\circ}C$ water for 7 days and a thermal cycling of 1000 cycles at 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$ baths were performed. Biaxial flexure test was conducted using the ball-on-three-ball method at the crosshead speed of 0.5mm/min. In order to investigate the deterioration of composite resins during the thermal cycling test, Weibull analysis for the biaxial flexure strengths was done. Fracture surfaces and the surfaces before and after the thermal cycling test were examined by SEM. The highest Weibull modulus value of 10.09 after thermal cycling tests which means the lowest strength variation, was observed in the CP group, and the lowest value of 4.47 was obsered in the LF Group. Biaxial flexure strengths and Knoop hardness numbers significantly decreased due to the thermal cycling ($\textit{p}$< 0.01), however, they recovered when specimens were drie4 The highest biaxial flexure strength of 125.65MPa was observed in the ZH group after the thermal cycling test, and the lowest value of 64.86MPa was observed in the CA group. Biaxial flexure strengths of ZH and CP groups were higher than those of PA, CF, and CA groups after thermal cycling test($\textit{p}$< 0.05). Knoop hardness numbers of CP group after the thermal cycling test was the highest(95.47 $\pm$ 7.35kg/$mm^2$) among the samples, while that of CA group was the lowest(30.73 $\pm$ 2.58kg/$mm^2$). Knoop hardness numbers showed the significant differences between the CP group and others after the thermal cycling test(($\textit{p}$< 0.05). Fracture surfaces showed that the composite resin failure developed along the matrix resin and the filler/resin interface region, and the cracks propagated in the conical shape from the maximum tensile stress zone.

  • PDF

Effects of Polishing Methods on the Surface Characteristics of Composite Resins (연마방법에 따른 복합레진의 표면특성 평가)

  • Baik, Min-Kyung;Kim, Chong-Chul;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.43 no.3
    • /
    • pp.275-283
    • /
    • 2016
  • The aim of this study was to evaluate the surface characteristics of composite resins polished with two different polishing methods. 30 disk-shaped specimens were prepared with microhybrid (Filtek$^{TM}$ Z250) and nanofilled (Filtek$^{TM}$ Z350) resins respectively, and classified into three groups: not polished as controls, polished by an abrasive disk (Soflex), and polished by a polishing brush (Occlubrush). Surface roughness was increased after polishing. In terms of micro-roughness, there were no significant differences between the two polishing methods. But macro-roughness values were markedly increased in the Occlubrush group (p < 0.05). In the Sof-lex group, the matrix and fillers were polished together, resulting into a smoother and homogeneous surface. However, in the Occlubrush group, the matrix layer was torn off, with more heterogeneous surfaces and large scratches. In regards to micro-hardness, no significant differences were observed between the two polishing systems (p > 0.05). And the hardness value increased about 25% after polishing. In conclusion, the method of polishing should be chosen deliberately in view of the hardness characteristics of composite resins. Sof-lex is recommended to improve the surface characteristics of polished resins.

METAMERISM IN COMPOSITE RESINS UNDER FIVE STANDARD ILLUMINANTS - D65, A, C, FCW AND TL84 (복합레진의 조건등색에 관한 연구)

  • Park, Ki-Jeong;Hwang, Yun-Chan;Kim, Sun-Ho;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.402-408
    • /
    • 2003
  • This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110. Charisma. Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate($L^{*}=96.54,{\;}a^{*}=0.19,{\;}b^{*}=0.01$) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus. Model 4000s. Hunter Lab. USA) by applying standard light source D^{65}, C. Fcw, TL84 and A. Standardization was done with reference standard(X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference (${\delta}E^{*}>2$). 2. All composites had MI below accepted value 0.5 between standard illuminant(D$_{65}$, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between $D^{65}$ and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

An Effect of Aging and Thermocycling on the Tensile Strength of Restorative Composite Resins (시효와 열순환 처리가 수복용 복합레진의 인장강도에 미치는 영향)

  • Lee, Mi-Jeong;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study was to evaluate effect of aging and thermocycling on the tensile strength of restorative composite resins. Eight commercially available light-cured restorative composites (Heliomolar: HM, Palfique Estelite: PE, Spectrum: ST, UniFil-F: UF, Z100: ZH, Clearfil AP-X: CA, P60: PS, and Palfique Toughwell: PT) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5 mm in gauge length and 2 mm in thickness. All samples were stored in distilled water at $37^{\circ}C$ for 100 days. Every 10 days, specimens were thermocycled for 1,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Tensile testing was carried out at a crosshead speed of 0.5 mm/min and fracture surfaces were observed with a scanning electron microscope. The results obtained were summarized as follows; 1. The strength degradation of thermocycled group was severer than that of the aged group (P<0.01). 2. The tensile strength of the CA and ST groups were significantly higher than that of other groups after thermocycling treatment (P<0.05). 3. Fracture surfaces showed that the composite resin failure developed along the matrix and the filler/resin interface region.

How does duration of curing affect the radiopacity of dental materials?

  • Bejeh Mir, Arash Poorsattar;Bejeh Mir, Morvarid Poorsattar
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.89-93
    • /
    • 2012
  • Purpose : Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. Materials and Methods : One mm thick samples of Filtek P60 and Clearfil resin composites were prepared and cured with three regimens of continuous 400 mW/$cm^2$ irradiance for 10, 20 and 30 seconds. Along with a 12-step aluminum step wedge, digital radiographs were captured and the radiopacities were transformed to the equivalent aluminum thicknesses. Data were compared by a general linear model and repeated-measures of ANOVA. Results : Overall, the calculated equivalent aluminum thicknesses of composite resins were increased significantly by doubling and tripling the curing times (F(2,8)=8.94, p=0.002). Notably, Bonferroni post-hoc tests confirmed that the radiopacity of the cured Filtek P60 was significantly higher at 30 seconds compared with 10 seconds (p=0.04). Although the higher radiopacity was observed by increasing the time, other comparisons showed no statistical significance (p>0.05). Conclusion : These results supported the hypothesis that the radiopacity of resin composites might be related to the duration of light curing. In addition to the current standards for radiopacity of digital images, defining a standard protocol for curing of dental materials should be considered, and it is suggested that they should be added to the current requirements for dental material.

Cure Monitoring of Composite Materials Using Dielectrometry (유전기법을 이용한 복합재료의 경화 모니터링)

  • 권재욱;김진국;김학성;이대길;최진경
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.42-45
    • /
    • 2000
  • The properties of thermosetting resins are dependent on the degree of cure and consolidation quality. Since the consolidation process of thermosetting resin matrix fiber composites is much dependent on the viscosity of resin in the composites, in this study, the dissipation factor which is a function of viscosity was measured by the newly developed Lacomtech dielectrometry apparatus and sensors. Using the measured dissipation factors, the relationship between the dissipation factor and degree of cure with respect to environmental temperature was investigated.

  • PDF