수종의 섬유보강재가 복합레진의 파절강도에 미치는 영향 (FRACTURE STRENGTH OF COMPOSITE RESIN WITH VARIOUS FIBER REINFORCING MATERIALS)

  • 박지만;조용범;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.371-380
    • /
    • 2000
  • The effect of fiber reinforcing materials on the fracture strength of composite resin was evaluated. Each ten composite resin bars reinforced by glassfiber[Fiber-Splint ML$^{(R)}$(Polydentia SA, Switzerland)], polyethylene fiber [Ribbond$^{(R)}$(Ribbond Inc., U.S.A.)] and polyaramid fiber[Kevlar$^{(R)}$(DuPont, U.S.A.)] were loaded under the 3-point compression technique. Another ten pure composite resin bars without reinforcement were used as a control group. Then mean fracture strength and standard deviation were calculated and a ANOVA and Scheffe test were used in statistics. The results were as follows: 1. Kevlar group showed the highest fracture strength as 175.5MPa (p<0.05). Fiber-Splint ML group showed the lowest fracture strength as 112.7MPa. 2. The mean value of fracture strength in Ribbond group was 136.4MPa, and that of unterated control group was 143.6MPa. No difference was found between the two groups. 3. Ribbond and Kevlar reinforcement groups showed a catastrophic failure, where complete separation of pieces occurs to a unseparated fracture pattern. The use of Kevlar reinforcement fibers with composite resin showed significant increase in the average load failure and the presence of the fibers did prevent the catastrophic crack propagation present in the unreinforced samples. The use of Ribbond reinforcement fibers with composite resin showed no significant increase in the average load failure. However, the presence of the fibers did prevent the catastrophic crack propagation. Because high strength of glassfiber are rapidly degraded on exposure to moisture and humidity. The use of Fiber-Splint ML reinforcement fibers with composite resin showed significant decrease in the average load failure and displayed catastrophic fractures.

  • PDF

Fiber-reinforced composite resin을 이용한 전치부 결손 수복 (REHABILITATION OF MISSING ANTERIOR TOOTH USING FIBER-REINFORCED COMPOSITE RESIN)

  • 박헌정;김종수;김용기
    • 대한소아치과학회지
    • /
    • 제26권1호
    • /
    • pp.62-68
    • /
    • 1999
  • One of the many dilemmas that the clinical restorative dentist must face is treating young adolescent patient who prematurely loses his permanent teeth. Temporary prosthetic replacement can be achieved with removable denture, orthodontic band-wire fixed denture, adhesion bridge, composite resin splint with reinforcing material until the patients go through growth and development. But, all of these have limitations. Advances in restorative materials and reinforcement materials have made possible new techniques which are as much esthetic, conservative and more economic and stronger than adhesion brides. Two cases are being presented where gas-plasma treated, woven polyethylene fabric to reinforce composite resin was used to fabricate a temporary prosthetic restoration to replace a missing maxillary central incisor. This relatively noninvasive and basically reversible procedure allows the patient to decide the final restoration as he or she goes thorough maturation of the hard and soft tissues.

  • PDF

변색된 치아의 심미성 회복에 관한 임상증례 (ESTHETIC IMPROVEMENT OF DISCOLORED TEETH : A CASE REPORT)

  • 정호석;김대업
    • 대한소아치과학회지
    • /
    • 제21권2호
    • /
    • pp.593-598
    • /
    • 1994
  • There were two cases of esthetic improvement of discolored teeth. First case was 12-year-old girl whose upper right central incisor was discolored after traumatic injury. She was treated by walking bleaching technique. Endodontic retreatment was done, and then the mixture of Superoxol and sodium perborate was applied and changed every week. After 3 weeks, esthetic result was obtained and fracture site was rcovered with light-curing composite resin. Second cases was 11-year-old girl whose teeth were discolored by fluorosis. She was treated by vital bleaching technique. A resin splint was made and then 30% and 15% carbamide peroxide was applied using this splint. After 4 weeks, a noticeable improvement in the color and the brightness of the teeth was achieved.

  • PDF

뇌성마비 환자에서 함입된 상악 중절치의 외과적 재위치: 증례보고 (SURGICAL REPOSITIONING OF AN INTRUDED PERMANENT MAXILLARY INCISOR IN A CEREBRAL PALSY PATIENT: A CASE REPORT)

  • 이고은;이명연;이제호
    • 대한장애인치과학회지
    • /
    • 제13권1호
    • /
    • pp.43-46
    • /
    • 2017
  • 본 증례는 함입 주소로 내원한 9세 4개월 뇌성마비 남환을 미다졸람 근주를 이용한 의식하 진정법으로 해당치아의 수술 적 재위치 및 근관치료를 시행하였다. 5년이 지난 현재 유착 소견 및 부분적인 치근흡수가 보이나 양호한 상태로 유지되고 있다. 뇌성마비 환자의 경우 치아 및 주위조직에 취약하며, 치료 시 적절한 행동조절 및 치료 방법을 선택하는 임상의의 노력이 필요하다.

Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro

  • Foek, Dave Lie Sam;Yetkiner, Enver;Ozcan, Mutlu
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.186-192
    • /
    • 2013
  • Objective: To analyze the fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro. Methods: Roots of human mandibular central incisors were covered with silicone, mimicking the periodontal ligament, and embedded in polymethylmethacrylate. The specimens (N = 50), with two teeth each, were randomly divided into five groups (n = 10/group) according to the retainer materials: (1) Interlig (E-glass), (2) everStick Ortho (E-glass), (3) DentaPreg Splint (S2-glass), (4) Ribbond (polyethylene), and (5) Quad Cat wire (stainless steel). After the recommended adhesive procedures, the retainers were bonded to the teeth by using flowable composite resin (Tetric Flow). The teeth were subjected to 10,00,000 cyclic loads (8 Hz, 3 - 100 N, $45^{\circ}$ angle, under $37{\pm}3^{\circ}C$ water) at their incisoproximal contact, and debonding forces were measured with a universal testing machine (1 mm/min crosshead speed). Failure sites were examined under a stereomicroscope (${\times}40$ magnification). Data were analyzed by one-way analysis of variance. Results: All the specimens survived the cyclic loading. Their mean debonding forces were not significantly different (p > 0.05). The DentaPreg Splint group (80%) showed the highest incidence of complete adhesive debonding, followed by the Interlig group (60%). The everStick Ortho group (80%) presented predominantly partial adhesive debonding. The Quad Cat wire group (50%) presented overlying composite detachment. Conclusions: Cyclic loading did not cause debonding. The retainers presented similar debonding forces but different failure types. Braided stainless steel wire retainers presented the most repairable failure type.

Successful Treatment Using Wire-reinforced Interdental Splint for a Puppy with Rostral Mandibular Fractures

  • Kim, Se Eun;Shim, Kyung Mi;Kim, Seung Hyun;Bae, Chun-Sik;Kang, Seong Soo
    • 한국임상수의학회지
    • /
    • 제35권4호
    • /
    • pp.137-140
    • /
    • 2018
  • A five-month-old toy poodle was referred for treatment of bilateral mandibular fractures. Preoperative skull and dental radiographs showed rostral mandibular fractures and permanent teeth that had not yet erupted. In addition to providing stability for the healing of fractures, it is very important to focus on restoring normal occlusion. The mandibular fractures were repaired using interdental wiring in a dentate area where the deciduous canines and fourth premolars were stable and could be used to anchor the interdental fixation. In the absence of an erupted permanent mandibular first molar, the modified Risdon wiring was performed using the deciduous mandibular fourth premolars as anchor teeth. An intraoral splint was placed on the mandibular teeth using self-curing composite resin. Five months after surgery, the patient had experienced no complications, and the permanent teeth had erupted normally. In this case, which involves a small-breed puppy with deciduous dentition, treatment with a wire-reinforced interdental splint using intact deciduous fourth premolar teeth as anchor teeth can be considered as a suitable method for rostral mandibular fracture restoration.

레진계 치아 스플린팅 재료들의 중합능력 평가 (Evaluation of polymerization ability of resin-based materials used for teeth splinting)

  • 이정길;김수연;이재관;김진우;박세희;조경모
    • 구강회복응용과학지
    • /
    • 제34권4호
    • /
    • pp.290-296
    • /
    • 2018
  • 목적: 본 연구의 목적은 치아 스플린팅에 사용되는 레진계 재료들의 두께에 따른 중합 능력을 평가하는 것이다. 연구 재료 및 방법: 레진계 스플린팅 재료로 개발된 Light-Fix와 G-FIX, 수복용과 스플린트용으로 사용 가능한 고흐름성 복합레진인 G-aenial Universal Flo를 사용하여 직경 5 mm, 두께 2, 3, 4, 5 mm의 시편을 각각 10개씩(총 120개) 제작하였다. 비커스 경도 측정기를 이용하여 시편 상면과 하면의 미세경도값을 측정하였다. 각 두께에서 복합레진의 중합정도를 95% 유의수준에서 independent T-test를 이용하여 통계적으로 분석하였다. 결과: Light-Fix와 G-FIX는 두께에 상관없이 중합도의 차이를 보이지 않았다. G-aenial Universal Flo는 3 mm 두께부터 유의하게 낮은 중합도를 보였다. 결론: 스플린팅 전용 레진계 재료인 Light-Fix와 G-FIX는 5 mm 두께까지 적절한 광중합이 가능할 것으로 사료된다.

여러 레진계 치아고정 재료의 굴곡강도 및 탄성계수 비교 (Comparison of flexural strength and modulus of elasticity in several resinous teeth splinting materials)

  • 유제인;김수연;;김진우;박세희;조경모
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.169-175
    • /
    • 2016
  • 목적: 본 연구의 목적은 수종의 레진계 치아고정 재료의 굴곡강도와 탄성계수를 비교 분석하는 것이다. 연구 재료 및 방법: 레진계 치아고정 재료로 Super-Bond C&B (SB), G-FIX (GF), G-aenial Universal Flo (GU), Filtek Z350 XT (FZ)를 이용하여 각 군당 15개씩 총 60개의 시편을 제작하였다. 3점 굽힘 시험으로 측정된 값에 따라 굴곡강도와 탄성계수를 계산하였다. 실험값은 One-way ANOVA test로 분석하고, Scheffe's test로 사후 검정하였다. 결과: 본 연구의 결과 SB는 다른 재료들과 비교 시 가장 낮은 굴곡강도를 보였으며 GF, GU, FZ는 비슷하게 높은 굴곡강도를 보였다. 탄성계수의 경우 SB가 가장 낮은 값을 보였고 GF는 SB보다는 높지만 GU와 FZ보다는 낮은 탄성계수를 보였으며 GU와 FZ는 유의하게 높은 탄성계수를 보였다. 결론: 동요치 고정을 목적으로 새로 개발된 GU (G-FIX)는 유동성 복합 레진과 수복용 복합 레진과 같이 높은 강도를 보이며 잘 파절되지 않으면서도 상대적으로 유연한 성질을 보여 동요치 고정에 유리할 것으로 사료된다.