• 제목/요약/키워드: composite groove

검색결과 37건 처리시간 0.027초

A theoretical mapping model for bridge deformation and rail geometric irregularity considering interlayer nonlinear stiffness

  • Leixin, Nie;Lizhong, Jiang;Yulin, Feng;Wangbao, Zhou;Xiang, Xiao
    • Steel and Composite Structures
    • /
    • 제46권1호
    • /
    • pp.93-105
    • /
    • 2023
  • This paper examines a high-speed railway CRTS-II ballastless track-bridge system. Using the stationary potential energy theory, the mapping analytical solution between the bridge deformation and the rail vertical geometric irregularity was derived. A theoretical model (TM) considering the nonlinear stiffness of interlayer components was also proposed. By comparing with finite element model results and the measured field data, the accuracy of the TM was verified. Based on the TM, the effect of bridge deformation amplitude, girder end cantilever length, and interlayer nonlinear stiffness (fastener, cement asphalt mortar layer (CA mortar layer), extruded sheet, etc.) on the rail vertical geometric irregularity were analyzed. Results show that the rail vertical deformation extremum increases with increasing bridge deformation amplitude. The girder end cantilever length has a certain influence on the rail vertical geometric irregularity. The fastener and CA mortar layer have basically the same influence on the rail deformation amplitude. The extruded sheet and shear groove influence the rail geometric irregularity significantly, and the influence is basically the same. The influence of the shear rebar and lateral block on the rail vertical geometric irregularity could be negligible.

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

  • Jin, Hosang;Jesseph, Fredrick B.;Ahmad, Salahuddin
    • 한국의학물리학회지:의학물리
    • /
    • 제25권2호
    • /
    • pp.65-71
    • /
    • 2014
  • A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the Varian Eclipse treatment planning system (TPS). An isocentrically mounted Sun Nuclear MapCHECK 2 diode array with 5 cm water-equivalent buildup was also used for the VMAT QAs and the measurements were compared to a composite dose plane from the Eclipse TPS. A ${\gamma}$ test was implemented in the Sun Nuclear Patient software with 10% threshold and absolute comparison at 1%/1 mm (dose difference/distance-to-agreement), 2%/2 mm, and 3%/3 mm criteria for both QA methods. The two-tailed paired Student's t-test was employed to analyze the statistical significance at 95% confidence level. The average ${\gamma}$ passing rates were greater than 95% at 3%/3 mm using both methods for all four energies. The differences in the average passing rates between the two methods were within 1.7% and 1.6% of each other when analyzed at 2%/2 mm and 3%/3 mm, respectively. The EPID passing rates were somewhat better than the MapCHECK 2 when analyzed at 1%/1 mm; the difference was lower for 8 MV and 10 MV. However, the differences were not statistically significant for all criteria and energies (p-values >0.05). The EPID-based QA showed large off-axis over-response and dependence of ${\gamma}$ passing rate on energy, while the MapCHECK 2 was susceptible to the MLC tongue-and-groove effect. The two fluence-based QA techniques can be an alternative tool of VMAT QA to each other, if the limitations of each QA method (mechanical sag, detector response, and detector alignment) are carefully considered.

안면부 피부암 절제 후 발생한 결손 부위에 V-Y-S 피판을 이용한 재건술 (Reconstruction with the 'V-Y-S Flap' for the Facial Defect after the Excision of a Skin Cancer)

  • 김규보;천지선;이승찬;조안영;양정열
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.541-545
    • /
    • 2006
  • Purpose: There are many methods for the reconstruction of the facial defect after an excision of a skin cancer; such as skin graft, local flap, free flap, etc... Skin graft has its' limitations; it could remain in different color with in regards of the recipient to donor, with an unfavorable scar. Free flap can lead to big donor site morbidity with long operation time and uncontrolled scar as a disadvantage factor. Compared to the prior, local flap offers several merits; sufficient blood supply, good tissue quality and short operation time. We revised 'V-Y-S flap' for the facial defect, which proved to have favorable outcomes. Methods: Total 7 V-Y-S flaps were performed to patients with skin cancers(six squamous cell carcinoma and one basal cell carcinoma). Two of these flaps were combined with composite grafts, one with full thickness skin graft. Six patients were female and one male. The average diameter of defects after excision was 2.3 cm. The follow-up period was 18 months maximally. Results: We treated seven facial skin cancers with 'V-Y-S flap'. There were no flap necrosis, cancer recurrence and scar contracture as a result. Furthermore, this method also offers a favorable central scar line that is parallel to the nasolabial fold and the nasojugal groove, especially in the nasolabial area and superomedial side of the cheek. With this method, we could cover a maximum diameter of 4cm facial defect. Conclusion: In conclusion, it is suggested that V-Y-S flap is a useful method to cover facial defects after the excision of a skin cancer.

Cyclic response and design procedure of a weak-axis cover-plate moment connection

  • Lu, Linfeng;Xu, Yinglu;Zheng, Huixiao;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.329-345
    • /
    • 2018
  • This paper systematically investigated the mechanical performance of the weak-axis cover-plate connection, including a beam end monotonic loading test and a column top cyclic loading test, and a series of parametric studies for exterior and interior joints under cyclic loading using a nonlinear finite element analysis program ABAQUS, focusing on the influences of the shape of top cover-plate, the length and thickness of the cover-plate, the thickness of the skin plate, and the steel material grade. Results showed that the strains at both edges of the beam flange were greater than the middle's, thus it is necessary to take some technical methods to ensure the construction quality of the beam flange groove weld. The plastic rotation of the exterior joint can satisfy the requirement of FEMA-267 (1995) of 0.03 rad, while only one side connection of interior joint satisfied ANSI/AISC 341-10 under the column top cyclic loading. Changing the shape or the thickness or the length of the cover-plate did not significantly affect the mechanical behaviors of frame joints no matter in exterior joints or interior joints. The length and thickness of the cover-plate recommended by FEMA 267 (1995) is also suitable to the weak-axis cover-plate joint. The minimum skin plate thickness and a design procedure for the weak-axis cover-plate connections were proposed finally.

Scanning Electron Microscopy을 이용한 완두 전분 복합면의 반죽구조 및 특성연구 (A study on the characteristics and noodle structure made from pea starch-wheat composite flour using a scanning electron microscopy)

  • 김은주;윤재영;김희섭
    • 한국식품조리과학회지
    • /
    • 제15권5호
    • /
    • pp.500-506
    • /
    • 1999
  • 완두 전분입자의 형태 및 완두 복합분의 반죽구조, 조리직후의 복합면의 내부구조를 SEM으로 조사한 결과는 다음과 같다. 완두전분은 타원형으로 그 크기가 불규칙적이고 다른 전분에 비해 크고 구부러지거나 들어간 모양이었다. 95$^{\circ}C$에서 가열하였을 때 완두전분은 부분적으로 중첩되었을 뿐 그 형태는 거의 유지하였다. P20과 C20의 반죽 구조는 밀가루 반죽에서의 큰 전분 입자들이 전체적으로 분포되어 있는 것에 비해 작은 전분입자들이 많아졌으며, P30은 다른 복합분 반죽의 구조보다 좀 더 많고 작은 전분입자들이 엉켜 있었다. 국수를 조리한 직후와 조리한 후 30분이 지난 뒤의 형태 변화를 관찰한 결과 P30과 P20의 조리된 직후의 형태는 각각 상이한 형태를 나타내었고 조리 30분후의 형태도 매우 다르게 나타났다. SEM으로 관찰된 P20과 C20의 구조는 밀가루 반죽과 큰 차이를 보이지 않아 제면시 영향을 주지 않을 것으로 보였으며 P30 역시 P20과 큰 차이를 나타내지 않아 제면적성으로는 문제가 없는 것으로 나타났다. Farinogram에 나타난 P20과 P30은 밀가루와 유사한 반죽시간과 중간정도의 안정도를 보이는 반면에 C20은 짧은 반죽시간과 낮은 안정도를 보였다. 대체로 C20이 P20, P30에 비해 도착시간과 반죽형성시간, 안정도가 짧게 나타났다. 또한 P20은 밀가루와 유사한 안정도와 반죽 저항도(MTI)를 나타냄으로서 제면적성에 적합함을 입증하였다.

  • PDF

상악 전치부에 발생한 이중치: 증례보고 (DOUBLE TEETH IN MAXILLARY PERMANENT INCISORS : CASE REPORTS)

  • 김미니;김영재;김정욱;장기택;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제36권1호
    • /
    • pp.119-125
    • /
    • 2009
  • 두 개의 치아가 하나로 붙은 것처럼 보이는 경우, 쌍생인지 융합인지 여부를 결정할 수 없을 경우에 이중치(double tooth)라는 용어를 사용한다. 이중치는 유치에 더 호발하나 영구치에도 약 0.1% 발생율을 보이며 심미적인 문제와 우식의 호발, 치주적 문제, 치열의 문제를 보일 수 있다. 이러한 이중치의 치료는 여러 전문 분야의 협진을 필요로 한다. 우선, 순측과 구개측의 중심구는 치아우식에 민감하므로 조기에 열구를 전색하는 것이 필요하며, 영구 치열에서는 융합치를 외과적으로 구강 내 또는 구강 외에서 분리한 후 교정적으로 배열할 수 있으며, 치관 모양을 다듬기 위하여 수복 치료가 필요할 수 있다. 한 개의 근관을 가진 경우는 순면구의 모양을 다듬고, 근원심 크기를 감소시킨 후 복합레진을 적용하는 방법도 있으나 불가피하게 발치해야 하는 경우도 있다. 이 경우 교정 및 보철 치료가 필요하며 임플란트 매식술도 고려된다. 그러나 이러한 치료의 선택은 임상적 상황에 맞추어 이루어져야한다. 이번 증례들에서도 심미적인 문제와 교합의 문제를 발견할 수 있었으며, 첫 번째 증례에서는 이런 문제를 해결하기 위하여 교정적, 근관치료, 레진 수복술, 외과적인 구강내 절제술을 이용하여 치료하였으나, 치근단 흡수가 관찰되었다. 두 번째와 세 번째 증례에서는 3차원 전산화 단층 촬영을 이용하여 정확한 치아의 내부와 외부 구조를 파악할 수 있었으며, 일반 방사선 사진으로는 판단이 어려운 근관 분리 여부와 근관의 융합 정도와 융합 위치 등을 진단할 수 있었다.

  • PDF

접착제와 와동형성의 차이에 따른 5급 복합레진 수복의 전향적 임상연구 (PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN CLASS V RESIN RESTORATIONS WITH OR WITHOUT MECHANICAL RETENTION)

  • 이경욱;정세준;한영철;손호현;엄정문;오명환;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권4호
    • /
    • pp.300-311
    • /
    • 2006
  • 본 연구의 목적은 복합레진을 이용한 비우식성 치경부 5급 병소 수복에 있어서, 3가지 다른 접착제를, 유지구를 부여한 치아와 부여하지 않은 치아에 적용하였을 때의 임상적인 효능의 차이를 비교하기 위함이다. 총 150개의 치아를 각각 25개씩 6개의 군으로 나누었다. A군 : Scotchbond Multi-Purpose (SBMP, 3M ESPE, St. Paul, MN, USA, 4세대 접착제)를 사용하고 유지구를 부여하지 않음. B군 : SBMP 를 사용하고 유지구를 부여. C군 : BC Plus (Vericom Co., Anyang, Gyeonggido, Korea, 5 세대 접착제)를 사용하고 유지구를 부여하지 않음. D군 : BC Plus를 사용하고 유지구를 부여. E군 : Adper Prompt (3M ESPE, Seefeld, Germany, 6 세대 접착제)를 사용하고 유지구를 부여하지 않음. F군 : Adper Prompt를 사용하고 유지구를 부여. 모든 치아는 복합레진인 Denfil (Vericom Co., Anyang, Gyeonggido, Korea) 을 이용하여 충전하였다. 수복 직후와 수복 6 개월 후에 modified USPHS (United States Public Health Service) criteria에 따라 수복물을 임상적으로 평가하였다. 추가적으로 임상사진을 촬영하였으며, 에폭시 레진을 이용하여 복제한 후 주사전자현미경을 이용하여 이를 관찰하였다. 6개월 후 관찰 결과, alpha rating의 수가 각 실험군마다 동일하지는 않았지만, 통계적으로는 3가지의 접착제간에 유의할만한 차이는 없었고, 기계적인 유지구를 부여한 군과 부여하지 않은 군 간에도 유의할만한 차이는 없었다 (p < 0.05). 그러나 6개월의 관찰 기간은 일반적으로 기대되는 레진의 수명보다 짧기 때문에, 각 실험군 간의 차이를 알아보기 위해서는 추후 더 오랜 기간의 관찰이 요구 된다.