• 제목/요약/키워드: composite beams and plates

검색결과 126건 처리시간 0.022초

Seismic performance of moment resisting steel frames retrofitted with coupled steel plate shear walls with different link beams

  • Amir Masoumi Verki;Adolfo Preciado;Pegah Amiri Motlagh
    • Steel and Composite Structures
    • /
    • 제46권5호
    • /
    • pp.591-609
    • /
    • 2023
  • In some buildings, the lateral structural response of steel framed buildings depends on the shear walls and it is very important to study the behavior of these elements under near-field seismic loads. The link beam in the opening of the shear wall between two wall plates is investigated numerically in terms of behavior and effects on frames. Based on the length of the beam and its bending and shear behavior, three types of models are constructed and analyzed, and the behavior of the frames is also compared. The results show that by reducing the length of the link beam, the base shear forces reduce about 20%. The changes in the length of the link beam have different effects on the degree of coupling. Increasing the length of the link beam increases the base shear about 15%. Also, it has both, a positive and a negative effect on the degree of coupling. The increasing strength of the coupling steel shear wall is linearly related to the yield stress of the beam materials, length, and flexural stiffness of the beam. The use of a shorter link beam will increase the additional strength and consequently improving the behavior of the coupling steel shear wall by reducing the stresses in this element. The link beam with large moment of inertia will also increase about 25% the additional strength and as a result the coefficient of behavior of the shear wall.

이동절점모드를 사용한 직교이방성 적층평판의 층간분리해석 (Delamination Analysis of Orthotropic Laminated Plates Using Moving Nodal Modes)

  • 안재석
    • 한국전산구조공학회논문집
    • /
    • 제25권4호
    • /
    • pp.293-300
    • /
    • 2012
  • 본 논문에서는 직교이방성 적층평판에서의 균열생성 및 전파로 이루어진 층간분리해석을 다룬다. 기존의 p-유한요소가 가지고 있는 요소의 강건성을 균열진전해석에 적용하여, 균열진전시 모델링을 재구성하지 않고, 균열 선단부에 해당되는 꼭지점 모드의 위치만을 이동하도록 하여, 요소망을 단순화시켰다. 이와 같은 층간분리해석에 대해서 이 논문에서의 주요 목적은 다음 두 가지이다. 첫째, 적층복합 재료의 층간분리해석 시, 일반적인 유한요소 모델과 비교하여 매우 간단한 요소망을 가지는 모델을 제안하는 것이다. 모델의 타당성을 평가하기 위해 적층 복합재료로 구성된 이중 외팔보 해석을 통하여, 기존 참고문헌 값과의 비교를 수행하였다. 둘째, 제안된 모델을 내부균열을 갖는 적층평판의 층간분리해석에 적용하여 여러 가지 거동 양상에 대한 평가이다. 이와 같은 목적을 수행하기 위하여 로바토 형상함수를 이용한 완전층별요소가 고려되었으며, 선형탄성파괴역학에 기초한 3차원 가상균열닫힘법을 이용하여 에너지 방출률을 산정하였다.

콘크리트채움 U형 강재보-강재기둥 합성 내진접합부에 대한 주기하중 실험 (Cyclic Seismic Testing of Concrete-filled U-shaped Steel Beam-to-Steel Column Connections)

  • 박홍근;이철호;박창희;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.337-347
    • /
    • 2011
  • 본 논문에서는 콘크리트 채움 U형 강재보와 강재 H단면 기둥으로 구성된 접합부의 내진 성능을 평가하였다. 접합부 내진성능을 평가하기 위하여 세 개의 보-기둥 접합부 실험체를 반복주기하중에 대하여 실험하였다. 합성보는 콘크리트 슬래브와 스터드를 이용하여 일체화 되었으며, 슬래브에는 부모멘트를 위한 철근이 배치되었다. 접합부 상세를 실험 변수로 하였으며, 보 접합부의 강화방안 및 약화방안, 합성효과의 정도를 고려하였다. 합성보의 춤은 슬래브 두께를 포함하여 600mm이며, 강재보와 슬래브의 철근은 H형강 기둥과 용접을 통해 접합하였다. 접합부 강화방안은 합성보 플랜지에 덧댐플레이트를 용접하였으며, 약화방안으로서 소성힌지 발생지점에 채움콘크리트 안에 스티로폼을 삽입하였다. 실험 결과 완전합성 실험체는 강도와 변형능력, 에너지 소산에 있어서 우수한 성능을 보여주었다. 변형능력은 특수모멘트골조 기준인 4% 이상의 회전각을 발휘하였다.

Computational optimized finite element modelling of mechanical interaction of concrete with fiber reinforced polymer

  • Arani, Khosro Shahpoori;Zandi, Yousef;Pham, Binh Thai;Mu'azu, M.A.;Katebi, Javad;Mohammadhassani, Mohammad;Khalafi, Seyedamirhesam;Mohamad, Edy Tonnizam;Wakil, Karzan;Khorami, Majid
    • Computers and Concrete
    • /
    • 제23권1호
    • /
    • pp.61-68
    • /
    • 2019
  • This paper presents a computational rational model to predict the ultimate and optimized load capacity of reinforced concrete (RC) beams strengthened by a combination of longitudinal and transverse fiber reinforced polymer (FRP) composite plates/sheets (flexure and shear strengthening system). Several experimental and analytical studies on the confinement effect and failure mechanisms of fiber reinforced polymer (FRP) wrapped columns have been conducted over recent years. Although typical axial members are large-scale square/rectangular reinforced concrete (RC) columns in practice, the majority of such studies have concentrated on the behavior of small-scale circular concrete specimens. A high performance concrete, known as polymer concrete, made up of natural aggregates and an orthophthalic polyester binder, reinforced with non-metallic bars (glass reinforced polymer) has been studied. The material is described at micro and macro level, presenting the key physical and mechanical properties using different experimental techniques. Furthermore, a full description of non-metallic bars is presented to evaluate its structural expectancies, embedded in the polymer concrete matrix. In this paper, the mechanism of mechanical interaction of smooth and lugged FRP rods with concrete is presented. A general modeling and application of various elements are demonstrated. The contact parameters are defined and the procedures of calculation and evaluation of contact parameters are introduced. The method of calibration of the calculated parameters is presented. Finally, the numerical results are obtained for different bond parameters which show a good agreement with experimental results reported in literature.

콘크리트채움 U형 강재보 - 콘크리트 기둥 접합부의 내진성능 (Seismic Resistance of Concrete-filled U-shaped Steel Beam-to-RC Column Connections)

  • 황현종;박홍근;이철호;박창희;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.83-97
    • /
    • 2011
  • 본 논문에서는 콘크리트 채움 U형 강재보와 철근콘크리트 기둥으로 구성된 접합부의 내진 상세를 개발하였다. 접합부 내진성능을 평가하기 위하여 세 개의 보-기둥 접합부 실험체를 반복주기하중에 대하여 실험하였다. 보춤과 기둥 단면 형상을 실험 변수로 하였다. 합성보의 춤은 슬래브 두께를 포함하여 610mm, 710mm이며, 철근콘크리트 기둥은 사각단면과 원형단면이 사용되었다. 접합부를 보강시키기 위하여 사각단면 기둥과 원형단면 기둥에 각각 대각 철근과 외다이어프램 강판을 사용한 특수 상세가 사용되었다. 실험 결과 실험체는 강도와 변형능력, 에너지 소산에 있어서 우수한 성능을 보여주었다. 변형능력은 특수모멘트골조 기준인 4% 이상의 층간변위각을 발휘하였다.

내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구 (An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes)

  • 이성희;정헌모;양일승;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2009
  • 최근 건물이 고층화 됨에 따라 건물의 중량감소와 시공의 효율성 확보를 위해 기존 S, RC, SRC 이외에 새로운 구조시스템이 적용되고 있으며, 그중에서도 CFT 구조는 우수한 구조성능과 시공성으로 많은 건설현장에 적용되어 왔다. CFT 구조는 접합부 구성시 보 플랜지 하중을 기둥과 반대편 보에 원활히 전달하기 위한 다이아그램이 필요하며 특히 기둥 좌우에 춤이 다른 보가 접합될 때 보의 하부 플랜지 하중전달을 위한 다이아프램 구성과 콘크리트 충전성 확보에 어려움이 있었다. 본 연구에서는 하부 보 플랜지 하중을 기둥에 원활히 전달하기 위해 CFT 기둥 내부에 유공판을 세로로 접합하는 형식의 접합상세를 제안하였다. 이 접합형식은 CFT 기둥 내부에 콘크리트가 충전될 때 콘크리트가 내부 유공판의 구멍을 관통하여 채워짐으로써 보 플랜지 하중전달에 콘크리트의 앵커효과를 이용하는 방법이며 유공판이 수직으로 설치됨으로써 콘크리트 충전성도 향상시킬 수 있다. 제안된 접합부의 구조거동분석을 위해서 내부유공판의 설치방향, 콘크리트의 충전 유/무, 내부유공판의 두께, 전단구멍의 개수등을 변수로하여 5개의 실험체를 제작하고 실험체의 실험적연구를 진행하였다.