• 제목/요약/키워드: composite actions

검색결과 72건 처리시간 0.019초

The Composite Action of Composite Truss Using H-Shaped Section Steel (H형강을 사용한 합성트러스의 합성효과)

  • Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • 제21권6호
    • /
    • pp.637-646
    • /
    • 2009
  • The composite actions of truss beams and floor slabs are not reflected on the design of the truss beam in domestic practice. In this research, basic experiments were conducted on a composite truss with the top and bottom chord members consisting of the H-shaped members. The tests were performed to evaluate the mechanical behaviors of the composite truss on the effects with the shear studs and without them. The specimens consisted of the steel truss and non-composite and composite trusses, and one-point-concentrated loading at the center and equivalent loading were monotonically applied. The composite effects were experimentally identified in the composite trusses using the shear stud connectors.

Behavior and calculation on concrete-filled steel CHS (Circular Hollow Section) beam-columns

  • Han, Lin-Hai;Yao, Guo-Huang;Zhao, Xiao-Ling
    • Steel and Composite Structures
    • /
    • 제4권3호
    • /
    • pp.169-188
    • /
    • 2004
  • A mechanics model is developed in this paper for concrete-filled steel CHS (circular hollow section) beam-columns. A unified theory is described where a confinement factor (${\xi}$) is introduced to describe the composite action between the steel tube and the filled concrete. The predicted load versus deformation relationship is in good agreement with test results. The theoretical model was used to investigate the influence of important parameters that determine the ultimate strength of concrete-filled steel CHS beam-columns. The parametric and experimental studies provide information for the development of formulas for the calculation of the ultimate strength of the composite beam-columns. Comparisons are made with predicted beam-columns strengths using the existing codes, such as LRFD-AISC-1999, AIJ-1997, BS5400-1979 and EC4-1994.

Progressive collapse analysis of stainless steel composite frames with beam-to-column endplate connections

  • Wang, Jia;Uy, Brian;Li, Dongxu;Song, Yuchen
    • Steel and Composite Structures
    • /
    • 제36권4호
    • /
    • pp.427-446
    • /
    • 2020
  • This paper carries out the progressive collapse analysis of stainless steel composite beam-to-column joint sub-models and moment-resisting frames under column removal scenarios. The static flexural response of composite joint sub-models with damaged columns was initially explored via finite element methods, which was validated by independent experimental results and discussed in terms of moment-rotation relationships, plastic hinge behaviour and catenary actions. Simplified finite element methods were then proposed and applied to the frame analysis which aimed to elaborate the progressive collapse response at the frame level. Nonlinear static and dynamic analysis were employed to evaluate the dynamic increase factor (DIF) for stainless steel composite frames. The results suggest that the catenary action effect plays an important role in preventing the damaged structure from dramatic collapse. The beam-to-column joints could be critical components that influence the capacity of composite frames and dominate the determination of dynamic increase factor. The current design guidance is non-conservative to provide proper DIF for stainless steel composite frames, and thus new DIF curves are expected to be proposed.

Elastic stiffness of stud connection in composite structures

  • Qin, Xi;Yang, Guotao
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.419-433
    • /
    • 2021
  • In composite structures, shear connectors are crucial components to resist the relative slip between the steel and concrete, and thereby to achieve the composite actions. In the service stage, composite structures are usually in elastic state, so the elastic stiffness of the shear connection is a quite important parameter in the structural analysis of composite structures. Nevertheless, the existing studies mainly focus on the load-slip relationship rather than the tangent stiffness at the initial elastic stage. Furthermore, when composite beams subjected to torque or local load, shear connections are affected by both tensile force and shear force. However, the stiffness of shear connections under combined effects appears not to have been discussed hitherto. This paper investigates the initial elastic stiffness of stud connections under combined effects of biaxial forces. The initial expression and the relevant parameters are obtained by establishing a simplified analytical model of the stud connection. Afterwards, parametric finite element analysis is performed to investigate the effects of the relevant factors, including the stud length, stud diameter, elastic modulus of concrete, elastic modulus of steel and volume ratio of reinforcement. The feasibility of the proposed modelling has been proved by comparing with sufficient experimental tests. Based on the analytical analysis and the extensive numerical simulations, design equations for predicting the initial elastic stiffness of stud connections are proposed. The comparison between the equations and the data of finite element models demonstrates that the equations are accurate enough to serve for engineering communities.

Finite Element Analysis of the Composite Box Girder (합성상형의 유한요소 해석)

  • 이정기;조진구;박근수
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제29권3호
    • /
    • pp.145-152
    • /
    • 1987
  • This paper suggests a method for the analysis of box girders which are subject to the membrane and the plate bending actions, Moreover, the method is applied to the box girders under distributed loads which have various geometrical types of cross sections and are made out of different materials. The approach is based on the finite element technique in which the structure is considered to be a spatial assemblage of flat plate elements and the deformations of the plates are to be approximated with 9-noded parabolic isoparametric elements. The results are summarized as follows. 1.In all models, the larger the widths of top flange inside of web are, the larger the vertical deflections are. 2.The maximum transverse and longitudinal moments in the composite box girders are judged to be larger than those in the RC box girders. 3.The transverse and the longitudinal moments in top flange of composite box. girders are larger than those in that of the RC box girders. 4.The transverse and longitudinal moments in web and bottom flange of the composite box girders are estimated to be very small in compare to those in web and bottom flange of the RC box girders.

  • PDF

Shear strength of connections between open and closed steel-concrete composite sandwich structures

  • Kim, Woo-Bum;Choi, Byong Jeong
    • Steel and Composite Structures
    • /
    • 제11권2호
    • /
    • pp.169-181
    • /
    • 2011
  • The behavior of connections between open sandwich slabs and double steel skin composite walls in steel plate-concrete(SC) structure is investigated by a series of experimental programs to identify the roles of components in the transfer of forces. Such connections are supposed to transfer shear by the action of friction on the interface between the steel surface and the concrete surface, as well as the shear resistance of the bottom steel plate attached to the wall. Experimental observation showed that shear transfer in slabs subjected to shear in short spans is explained by direct force transfer via diagonal struts and indirect force transfer via truss actions. Shear resistance at the interface is enhanced by the shear capacity of the shear plate as well as friction caused by the compressive force along the wall plate. Shear friction resistance along the wall plate was deduced from experimental observation. Finally, the appropriate design strength of the connection is proposed for a practical design purpose.

Tests on fiber reinforced concrete filled steel tubular columns

  • Gopal, S. Ramana;Devadas Manoharan, P.
    • Steel and Composite Structures
    • /
    • 제4권1호
    • /
    • pp.37-48
    • /
    • 2004
  • This paper deals with the strength and deformation of both short and slender concrete filled steel tubular columns under the combined actions of axial compression and bending moment. Sixteen specimens were tested to investigate the effect of fiber reinforced concrete on the ultimate strength and behavior of the composite column. The primary test parameters were load eccentricity and column slenderness. Companion tests were also undertaken on eight numbers of similar empty steel tubes to highlight the synergistic effects of composite column. The test results demonstrate the influence of fiber reinforced concrete on the strength and behavior of concrete filled steel tubular columns.

A Study on the Sound Insulation Performance of the Composite-Material Panel for Railroad Vehicle (철도차량 내장재용 복합재료 패널의 차음성능에 관한 연구)

  • 김봉기;김재승;김현실;강현주;김상렬
    • Journal of the Korean Society for Railway
    • /
    • 제6권1호
    • /
    • pp.10-14
    • /
    • 2003
  • Since most of main noise sources of the railroad vehicle are transmitted to the passenger's ear through the vibration of the panel, the sound insulation performance of the panels should be high enough to protect the passenger's ear from the noisy environment. Specifically, the composite materials which are generally used for reducing the weight of the vehicle compartment have the low insulation performance, thus noise control actions should be taken appropriately by considering the insulation performance of the panels. In this study, the insulation performances of the inner/outer panels of the compartment are evaluated. In addition, the contribution of the insulation performance of aluminum door is estimated and compared to those of composite panels. The results can furnish an in-depth understanding of the insulation characteristics of the panel of railroad vehicle.

Temperature distribution in a full-scale steel framed building subject to a natural fire

  • Wald, Frantisek;Chladna, Magdalena;Moore, David;Santiago, Aldina;Lennon, Tom
    • Steel and Composite Structures
    • /
    • 제6권2호
    • /
    • pp.159-182
    • /
    • 2006
  • Current fire design codes for determining the temperature within the structural elements that form part of a complete building are based on isolated member tests subjected to the standard fire. However, the standard time-temperature response bears little relation to real fires and doesn't include the effects of differing ventilation conditions or the influence of the thermal properties of compartment linings. The degree to which temperature uniformity is present in real compartments is not addressed and direct flame impingement may also have an influence, which is not considered. It is clear that the complex thermal environmental that occurs within a real building subject to a natural fire can only be addressed using realistic full-scale tests. To study global structural and thermal behaviour, a research project was conducted on the eight storey steel frame building at the Building Research Establishment's Cardington laboratory. The fire compartment was 11 m long by 7 m wide. A fire load of $40kg/m^2$ was applied together with 100% of the permanent actions and variable permanent actions and 56% of live actions. This paper summarises the experimental programme and presents the time-temperature development in the fire compartment and in the main supporting structural elements. Comparisons are also made between the test results and the temperatures predicted by the structural fire Eurocodes.

Experimental and numerical studies on concrete encased embossments of steel strips under shear action for composite slabs with profiled steel decking

  • Seres, Noemi;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • 제11권1호
    • /
    • pp.39-58
    • /
    • 2011
  • The subject of the ongoing research work is to analyze the composite action of the structural elements of composite slabs with profiled steel decking by experimental and numerical studies. The mechanical and frictional interlocks result in a complex behaviour and failure under horizontal shear action. This is why the design characteristics can be determined only by standardized experiments. The aim of the current research is to develop a computational method which can predict the behaviour of embossed mechanical bond under shear actions, in order to derive the design characteristics of composite slabs with profiled steel decking. In the first phase of the research a novel experimental analysis is completed on an individual concrete encased embossment of steel strip under shear action. The experimental behaviour modes and failure mechanisms are determined. In parallel with the tests a finite element model is developed to follow the ultimate behaviour of this type of embossment, assuming that the phenomenon is governed by the failure of the steel part. The model is verified and applied to analyse the effect of embossment's parameters on the behaviour. In the extended investigation different friction coefficients, plate thicknesses, heights and the size effects are studied. On the basis of the results the tendencies of the ultimate behaviour and resistance by the studied embossment's characteristics are concluded.