Progressive collapse analysis of stainless steel composite frames with beam-to-column endplate connections  

Wang, Jia (School of Civil Engineering, The University of Sydney)
Uy, Brian (School of Civil Engineering, The University of Sydney)
Li, Dongxu (School of Civil Engineering, The University of Sydney)
Song, Yuchen (School of Civil Engineering, The University of Sydney)
Publication Information
Steel and Composite Structures / v.36, no.4, 2020 , pp. 427-446 More about this Journal
Abstract
This paper carries out the progressive collapse analysis of stainless steel composite beam-to-column joint sub-models and moment-resisting frames under column removal scenarios. The static flexural response of composite joint sub-models with damaged columns was initially explored via finite element methods, which was validated by independent experimental results and discussed in terms of moment-rotation relationships, plastic hinge behaviour and catenary actions. Simplified finite element methods were then proposed and applied to the frame analysis which aimed to elaborate the progressive collapse response at the frame level. Nonlinear static and dynamic analysis were employed to evaluate the dynamic increase factor (DIF) for stainless steel composite frames. The results suggest that the catenary action effect plays an important role in preventing the damaged structure from dramatic collapse. The beam-to-column joints could be critical components that influence the capacity of composite frames and dominate the determination of dynamic increase factor. The current design guidance is non-conservative to provide proper DIF for stainless steel composite frames, and thus new DIF curves are expected to be proposed.
Keywords
progressive collapse; stainless steel; beam-to-column joints; static and dynamic; composite frames;
Citations & Related Records
Times Cited By KSCI : 9  (Citation Analysis)
연도 인용수 순위
1 Guo, L., Gao, S. and Fu, F. (2015), "Structural performance of semi-rigid composite frame under column loss", Eng. Struct., 95, 112-126. https://doi.org/10.1016/j.engstruct.2015.03.049.   DOI
2 Li, G.Q., Li, L.L., Jiang, B. and Lu, Y. (2018), "Experimental study on progressive collapse resistance of steel frames under a sudden column removal scenario", J. Constr. Steel Res., 147, 1-15. https://doi.org/10.1016/j.jcsr.2018.03.023.   DOI
3 Lichtenfeld, J.A., Van Tyne, C.J. and Mataya, M.C. (2006), "Effect of strain rate on stress-strain behavior of alloy 309 and 304L austenitic stainless steel", Metallurgical Mater. T. A, 37(1), 147-161. https://doi.org/10.1007/s11661-006-0160-5.   DOI
4 Lin, Z., Liu, Y. and He, J. (2014), "Behavior of stud connectors under combined shear and tension loads", Eng. Struct., 81, 362-376. https://doi.org/10.1016/j.engstruct.2014.10.016.   DOI
5 Liu, M. (2013), "A new dynamic increase factor for nonlinear static alternate path analysis of building frames against progressive collapse", Eng. Struct., 48, 666-673. https://doi.org/10.1016/j.engstruct.2012.12.011.   DOI
6 Mashhadi, J. and Saffari, H. (2016), "Effects of damping ratio on dynamic increase factor in progressive collapse", Steel Compos. Struct., 22(3), 677-690. https://doi.org/10.12989/scs.2016.22.3.677.   DOI
7 McKay, A. (2008), "Alternative path method in progressive collapse analysis: Variation of dynamic and non-linear load increase factors", M.S. Dissertation, The University of Texas, San Antonio.
8 McKay, A., Marchand, K. and Diaz, M. (2012), "Alternate path method in progressive collapse analysis: Variation of dynamic and nonlinear load increase factors", Practice Periodical on Structural Design and Construction, 17(4), 152-160. https://doi.org/10.1061/(ASCE)SC.1943-5576.0000126.   DOI
9 Mirtaheri, M. and Zoghi, M.A. (2016), "Design guides to resist progressive collapse for steel structures", Steel Compos. Struct., 20(2), 357-378. https://doi.org/10.12989/scs.2016.20.2.357.   DOI
10 ABAQUS (2016), User Manual. Version 6.16, DS SIMULIA Corp, Providence, RI, USA.
11 ANSI/AISC 360 (2010), Specification for structural steel buildings, American Institute of Steel Construction; Chicago-Illinois, USA.
12 AS 4100 (1998), Steel Structures, the Council of Standards Australia; Sydney, Australia.
13 Cai, Y. and Young, B. (2019), "Experimental investigation of carbon steel and stainless steel bolted connections at different strain rates", Steel Compos. Struct., 30(6), 551-565. https://doi.org/10.12989/scs.2019.30.6.551.   DOI
14 ASCE/SEI 41-17 (2017), Seismic evaluation and retrofit of existing buildings. American Society of Civil Engineers; Virginia, USA.
15 AS/NZS 1170.1 (2002), Structural design actions Part 1: Permanent, imposed and other actions, the Council of Standards Australia; Sydney, Australia.
16 AS/NZS 2327 (2017), Composite structures-Composite steel-concrete construction in buildings, the Council of Standards Australia; Sydney, Australia.
17 Carreira, D.J. and Chu, K.H. (1985), "Stress-strain relationship for plain concrete in compression", J. Proceedings, 82(6), 797-804.
18 Song, Y., Uy, B. and Wang, J. (2019), "Numerical analysis of stainless steel-concrete composite beam-to-column joints with bolted flush endplates", Steel Compos. Struct., 33(1), 143-162. https://doi.org/10.12989/scs.2019.33.1.143.   DOI
19 Pavlovic, M., Markovic, Z., Veljkovic, M. and Budevac, D. (2013), "Bolted shear connectors vs. headed studs behaviour in push-out tests", J. Constr. Steel Res., 88, 134-149. https://doi.org/10.1016/j.jcsr.2013.05.003.   DOI
20 Sadek, F., Main, J.A., Lew, H.S. and Bao, Y. (2011), "Testing and analysis of steel and concrete beam-column assemblies under a column removal scenario", J. Struct. Eng., 137(9), 881-892. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000422.   DOI
21 UFC 4-023-03 (2009), Design of buildings to resist progressive collapse. Unified Facilities Criteria, U.S. Department of Defense; Washington, D.C., USA.
22 Wang, J., Uy, B. and Li, D. (2019), "Behaviour of large fabricated stainless steel beam-to-tubular column joints with extended endplates", Steel Compos. Struct., 32(1), 141-156. https://doi.org/10.12989/scs.2019.32.1.141.   DOI
23 Wang, J., Uy, B., Thai, H.T. and Li, D. (2018a), "Behaviour and design of demountable beam-to-column composite bolted joints with extended end-plates", J. Constr. Steel Res., 144, 221-235. https://doi.org/10.1016/j.jcsr.2018.02.002.   DOI
24 Wang, J., Zhu, H., Uy, B., Patel, V., Aslani, F. and Li, D. (2018b), "Moment-rotation relationship of hollow-section beam-to-column steel joints with extended end-plates", Steel Compos. Struct., 29(6), 717-734. https://doi.org/10.12989/scs.2018.29.6.717.   DOI
25 Yang, B., Tan, K.H., Xiong, G. and Nie, S.D. (2016), "Experimental study about composite frames under an internal column-removal scenario", J. Constr. Steel Res., 121, 341-351. https://doi.org/10.1016/j.jcsr.2016.03.001.   DOI
26 Xu, M., Gao, S., Guo, L., Fu, F. and Zhang, S. (2018), "Study on collapse mechanism of steel frame with CFST-columns under column-removal scenario", J. Constr. Steel Res., 141, 275-286. https://doi.org/10.1016/j.jcsr.2017.11.020.   DOI
27 Yang, B. and Tan, K.H. (2013), "Experimental tests of different types of bolted steel beam-column joints under a central-column-removal scenario", Eng. Struct., 54, 112-130. https://doi.org/10.1016/j.engstruct.2013.03.037.   DOI
28 Yang, B., Tan, K.H. and Xiong, G. (2015), "Behaviour of composite beam-column joints under a middle-column-removal scenario: Component-based modelling", J. Constr. Steel Res., 104, 137-154. https://doi.org/10.1016/j.jcsr.2014.10.003.   DOI
29 Zhu, Y.F., Chen, C.H., Yao, Y., Keer, L.M. and Huang, Y. (2018), "Dynamic increase factor for progressive collapse analysis of semi-rigid steel frames", Steel Compos. Struct., 28(2), 209-221. https://doi.org/10.12989/scs.2018.28.2.209.   DOI
30 Cassiano1a, D., D'Aniello, M., Rebelo, C., Landolfo, R. and da Silva, L.S. (2016), "Influence of seismic design rules on the robustness of steel moment resisting frames", Steel Compos. Struct., 21(3), 479-500. https://doi.org/10.12989/scs.2016.21.3.479.   DOI
31 Chen, J., Huang, X., Ma, R. and He, M. (2012), "Experimental study on the progressive collapse resistance of a two-story steel moment frame", J. Perform. Constr. Fac., 26(5), 567-575. https://doi.org/10.1061/(ASCE)CF.1943-5509.0000287.   DOI
32 Elflah, M., Theofanous, M., Dirar, S. and Yuan, H. (2019), "Behaviour of stainless steel beam-to-column joints-Part 1: Experimental investigation", J. Constr. Steel Res., 152, 183-193. https://doi.org/10.1016/j.jcsr.2018.02.040.   DOI
33 FEMA 356 (2000), Prestandard and commentary for the seismic rehabilitation of buildings, American Society of Civil Engineers; Virginia, USA.
34 EN 1993-1-8 (2005), Eurocode 3: Design of steel structures - Part 1-8: Design of joints, European Committee for Standardization; Brussels, Belgium.
35 EN 1994-1-1 (2004), Eurocode 4: Design of composite steel and concrete structures - Part 1-1: General rules and rules for buildings, European Committee for Standardization; Brussels, Belgium.
36 Faella, C., Martinelli, E. and Nigro, E. (2003), "Shear connection nonlinearity and deflections of steel-concrete composite beams: a simplified method", J. Struct. Eng., 129(1), 12-20. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:1(12).   DOI
37 Gardner, L., Bu, Y., Francis, P., Baddoo, N.R., Cashell, K.A. and McCann, F. (2016), "Elevated temperature material properties of stainless steel reinforcing bar", Constr. Build. Mater., 114, 977-997. https://doi.org/10.1016/j.conbuildmat.2016.04.009.   DOI
38 GSA (2003), Progressive collapse analysis and design guidelines for new federal office buildings and major modernization projects, U.S. General Services Administration; Washington, D.C., USA.