• 제목/요약/키워드: component state test

검색결과 131건 처리시간 0.033초

Experimental study on the vertical bearing behavior of nodular diaphragm wall in sandy soil based on PIV technique

  • Jiujiang Wu;Longjun Pu;Hui Shang;Yi Zhang;Lijuan Wang;Haodong Hu
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.195-208
    • /
    • 2023
  • The nodular diaphragm wall (NDW) is a novel type of foundation with favorable engineering characteristics, which has already been utilized in high-rise buildings and high-speed railways. Compared to traditional diaphragm walls, the NDW offers significantly improved vertical bearing capacity due to the presence of nodular parts while reducing construction time and excavation work. Despite its potential, research on the vertical bearing characteristics of NDW requires further study, and the investigation and visualization of its displacement pattern and failure mode are scant. Meanwhile, the measurement of the force component acting on the nodular parts remains challenging. In this paper, the vertical bearing characteristics of NDW are studied in detail through the indoor model test, and the displacement and failure mode of the foundation is analyzed using particle image velocimetry (PIV) technology. The principles and methods for monitoring the force acting on the nodular parts are described in detail. The research results show that the nodular part plays an essential role in the bearing capacity of the NDW, and its maximum load-bearing ratio can reach 30.92%. The existence of the bottom nodular part contributes more to the bearing capacity of the foundation compared to the middle nodular part, and the use of both middle and bottom nodular parts increases the bearing capacity of the foundation by about 9~12% compared to a single nodular part of the NDW. The increase in the number of nodular parts cannot produce a simple superposition effect on the resistance born by the nodular parts since the nodular parts have an insignificant influence on the exertion and distribution of the skin friction of NDW. The existence of the nodular part changes the displacement field of the soil around NDW and increases the displacement influence range of the foundation to a certain extent. For NDWs with three different nodal arrangements, the failure modes of the foundations appear to be local shear failures. Overall, this study provides valuable insights into the performance and behavior of NDWs, which will aid in their effective utilization and further research in the field.

한국어판 간이걱정척도의 개발 (Development of the Korean Version of the Brief Measure of Worry Severity(BMWS))

  • 임재형;조숙행;한창수;김승현;양재원;이문수;정현강;고영훈
    • 정신신체의학
    • /
    • 제19권2호
    • /
    • pp.92-100
    • /
    • 2011
  • 연구목적: 본 연구에서는 한국어판 간이걱정척도(Brief Measure of Worry Severity, BMWS)를 개발하고, 척도의 신뢰도와 타당도 및 요인 구성을 평가하였다. 또한 병적인 걱정이 우울 및 불안과 관련되어 있는지를 알아보았다. 방 법: 지역사회 일반인 및 대학생 352명이 간이걱정척도를 시행하였으며, 이 중 27명은 3주 후 척도를 재시행하였다. Cronbach's ${\alpha}$ 계수와 검사-재검사 일치도를 통해 척도의 신뢰도를 평가하였다. 외적 타당도는 간이걱정척도의 점수와 Beck 우울척도(Beck Depression Inventory, BDI), Patient Health questionnaire-2(PHQ-2), 상태 불안척도(State Anxiety Inventory, SAI), 특성 불안척도(Trait Anxiety Inventory, TAI) 각각의 점수와의 상관도를 확인함으로써 평가하였다. 또한 구성 타당도를 평가하기 위해 주성분 분석을 시행하였다. 병적인 걱정이 우울 및 불안과 관련되어 있는지 여부는 간이걱정척도의 점수와 BDI 및 TAI 점수를 편상관 분석하여 알아보았다. 결 과: 척도의 Cronbach's ${\alpha}$ 계수는 0.904였으며, 검사-재검사 상관도는 0.56(P<0.01)이었다. 간이걱정척도 점수와 BDI, PHQ-2, SAI, 그리고 TAI 점수의 상관도는 각각 0.60(P<0.01), 0.42(P<0.01), 0.36(P<0.01), 0.59(P<0.01)이었다. 주성분 분석상 척도는 하나의 요인으로 구성되어 있었다. TAI 점수를 통제한 상태에서 간이걱정척도 점수와 BDI 점수의 상관 계수는 0.357(P<0.01)이었으며, BDI 점수를 통제한 상태에서 간이걱정척도 점수와 TAI 점수의 상관 계수는 0.446(P<0.01)이었다. 결 론: 본 연구에서는 한국어판 간이걱정척도가 병적인 걱정을 측정하는데 있어 신뢰할 수 있고 타당한 도구임을 밝힐 수 있었다. 또한 병적인 걱정이 불안뿐만 아니라 우울과도 관련되어 있음을 확인할 수 있었다.

  • PDF

가속도 계측 자료를 이용한 콘크리트 교량의 처짐 산정 (Calculation of Deflection Using the Acceleration Data for Concrete Bridges)

  • 윤영균;유희중
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권5호
    • /
    • pp.92-100
    • /
    • 2011
  • 본 연구는 실제 교량에서 차량 주행에 따른 가속도 계측 자료를 이용하여 교량의 고유진동수를 진동 모드별로 파악한 후, 수치 모델링을 통하여 유도된 동적하중에 따른 6차 모드까지의 고유진동수를 고려하여 처짐을 계산할 수 있는 산정식에 관한 것이다. 처짐 계산식은 모드중첩법에 의한 비감쇠 강제진동 이론을 이용하여 교량을 등속도로 이동하는 동적 주행하중에 의해 발생하는 처짐을 계산할 수 있도록 수치 모델링을 하였으며, 이를 검증하고 자동으로 계산할 수 있도록 하였다. 그리고, 제안된 처짐 계산식을 검증하기 위하여 콘크리트 교량을 대상으로 동적재하시험을 실시하여 처짐을 측정하고 이 값을 본 연구의 처짐 계산식의 결과와 비교하여 정확성 및 타당성 검증을 실시하였다. 이 결과, 본 연구에서 제시하는 처짐 계산식은 고유진동수를 고려하는 진동모드의 차수가 낮은 경우에 비교적 정확한 처짐을 예측하며, 주행속도에 따라서는 적용하는 진동 모드 차수에 의하여 처짐 예측의 정확도가 영향을 받는 것을 확인하였다. 그리고, 주행속도가 비교적 빠른 경우에 한하여 본 연구에서 제시하는 처짐 계산식은 진동 모드에 상관없이 비교적 정확하고 신뢰도가 양호한 계산 결과를 얻을 수 있는 것으로 나타났다.

자외선 노출에 의한 Walnut 베니어의 광 변색 방지 연구 (Studies on Photoprotection of Walnut Veneer Exposed to UV Light)

  • 박세영;홍창영;김선홍;최준호;이효진;최인규
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권3호
    • /
    • pp.221-230
    • /
    • 2018
  • 본 연구에서는 자외선 노출에 의한 목재베니어의 광 열화를 방지하기 위하여 변색 요인을 제거하여 그 효과를 평가하고자 하였다. 목재 중 추출물함량이 높고 어두운 색상을 나타내며 고급용재로 사용되고 있는 대표 활엽수종인 walnut을 공시재료로 선택하여 광 열화 분석 및 방지법에 관한 연구에 사용하였다. 베니어 내 발색단을 함유하는 물질을 탈리하기 위해 실시한 알코올-벤젠, 과산화수소 및 차아염소산나트륨 수용액 처리 후 광 안정성 평가를 실시하였다. 광 변색인자로 알려진 추출물 성분의 제거 후에는 색 안정화 효과를 보이지 않았다. 한편, 리그닌 성분을 제거하기 위하여 과산화수소를 20, 30% 농도로 하여 $75^{\circ}C$에서 1시간 처리하였으며, 그 결과 표면색상에 대한 표백효과는 나타내었으나 추출물 용출에 따른 재색 유지가 어려우며 광 노출에 대한 안정화 효과를 나타내지 않았다. 반면, 차아염소산나트륨 수용액을 1, 2 및 3% 농도로 하여 동일 온도 및 시간 조건에서 처리 한 베니어의 광 노출 평가결과, 추출물 용출에 의한 재색변화는 나타났지만, 광 노출에 의한 색상 변화는 관찰되지 않았으므로 우수한 안정화 효과를 나타낼 수 있었다. 하지만, 3% 이상 농도에서는 베니어 표면의 거칠기와 손상이 발생되므로, walnut 베니어의 경우 적정 농도조건에서의 처리가 필요한 것으로 사료된다.

도시철도 침목플로팅궤도 궤도구성품의 손상평가 (Damage Evaluation of Track Components for Sleeper Floating Track System in Urban Transit)

  • 최정열;김학선;한경성;장철주;정지승
    • 문화기술의 융합
    • /
    • 제5권4호
    • /
    • pp.387-394
    • /
    • 2019
  • 본 연구에서는 도시철도 침목플로팅궤도(STEDEF) 궤도구성품의 손상영향을 분석하기 위하여 20년 이상 공용중인 현장에서 시료를 채취하여 궤도재료에 대한 육안검사와 실내시험 및 유한요소해석을 통해 궤도구성품의 손상취약부를 분석하였다. 육안검사결과 레일패드와 체결구는 특이사항이 없었으나 침목방진상자는 모서리부분의 마모 및 찢어지는 현상이 발생하였다. 침목방진패드는 두께감소 및 피로경화층이 뚜렷하게 조사되었다. 레일패드와 침목방진패드에 대한 스프링강성 시험결과, 레일패드의 노후는 뚜렷하지 않았으나 침목방진패드는 설계기준치를 크게 상회하는 것으로 나타나 침목방진패드는 통과톤수에 직접적인 영향을 받는 것으로 분석되었다. 현장시료의 열화상태와 수치해석 결과와의 비교결과, 수치해석모델의 응력 및 변위 집중위치와 현장시료의 손상위치가 일치하는 것으로 나타나 공용중인 침목플로팅궤도 궤도구성품의 손상취약부를 실험 및 해석적으로 입증하였다.

LNG 저장탱크 구조물의 종합적 상태평가기준 개발 (A Development of Representative Condition Evaluation Standard for LNG Storage Tank Structures)

  • 김정훈;조영도
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.44-51
    • /
    • 2018
  • LNG저장탱크가 노후화 됨에 따라 외벽 콘크리트에 균열, 철근부식 등 결함이 발생할 경우, 손상 종류 및 정도에 따라 구조물의 붕괴 등 대형사고 발생 위험이 존재하게 된다. LNG저장탱크는 2014년부터 정밀안전진단이 시작 되어 안전점검이 수행되고 있으며, 부재별 상태평가기준은 2016년 1월에 개정되어 적용하고 있다. 상태평가는 액화천연가스 저장탱크에 대한 외관 조사 및 재료시험 결과를 바탕으로 저장탱크에 대한 상태를 평가하는 것을 말하는 것으로 유지관리에 있어서 중요하다. 또한 각각의 LNG 저장탱크 대표상태를 나타내는 종합적 상태평가기준이 유지관리 시 중요하지만, LNG저장탱크 외조 콘크리트에 대한 관련 기준이 국내 외에 부재하여 상태평가 기준 개발 필요하다. 이 논문에서는 LNG 저장탱크 구조적 특성 검토, 부재별 상태평가 기준현황 분석, 부재별 가중치 부여를 통한 종합적 상태등급 산정 방안을 수립하였다. 부재별 가중치 산출은 AHP(Analytic Hierarchy process)기법을 이용하고 전문기관의 설문조사 등을 통해 종합적 상태평가 기준을 개발하였다.

BRCA 돌연변이 가계의 심리상태 및 삶의 질 평가 (Evaluation of Psychosocial Impact and Quality of Life in BRCA Mutation Family)

  • 한상아;김새리;강은영;김정현;하태현;양은주;임재영;한원식;노동영;김성원
    • Journal of Genetic Medicine
    • /
    • 제7권1호
    • /
    • pp.67-77
    • /
    • 2010
  • 목 적: 본 연구는 한국인 BRCA 유전자 돌연변이 가계구성원들을 대상으로 암진단 및 돌연변이 보유 여부가 심리 상태와 삶의 질에 미치는 영향을 알아보기 위해 시행되었다. 대상 및 방법: BRCA 유전자 돌연변이를 가진 13가계에서 암에 이환된 보인자 17명, 이환되지 않은 보인자 16명, 건강한 비보인자 13명이 본 연구의 분석에 포함되었다. 이 세 군을 대상으로 우울, 불안, 낙관, 유전성 유방암관련 지식수준과 삶의 질을 설문을 통하여 평가하였다. 결 과: 설문시기는 유전자 검사 후 평균 21개월(6-35)로 세 군 간의 차이는 없었다(P=0.254). 세 군 간의 우울, 낙관, 육체적 삶의 질은 유사했다. 불안은 세 군 모두에서 일반인 보다 상승되어 있었다. 이환된 보인자의 정신적 삶의 질은 암에 이환된 보인자가 다른 두 군에 비해 유의하게 낮았다(P=0.009, P=0.017). 다변량 분석 결과 정신적 삶의 질에 영향을 미친 인자는 암이환여부(P=0.043)와 직업유무(P=0.008) 였다. 결 론: 같은 돌연변이 가계 내에서 돌연변이 유무는 우울, 불안, 낙관에서 심리적반작용을 일으키지 않았으나, 돌연변이 가계 구성원의 불안 수준은 돌연변이 유무에 관계 없이 높았다. 본 연구는 소규모 표본을 대상으로 한 단면적 연구이나, BRCA 유전자 검사에 수반될 수 있는 심리적 스트레스 및 그에 대한 대처법을 수립하는 데 기초연구로 의의를 가진다.

조리실습 교육에 대한 교사의 관심도, 실행 수준, 실행 형태 및 지원 요구도 조사 (A Study on Stage of Concern, Level of Use, Innovation Configuration, and Intervention demand of Teachers in Culinary Practice Education)

  • 박은숙;김영남
    • 한국가정과교육학회지
    • /
    • 제18권3호
    • /
    • pp.41-60
    • /
    • 2006
  • 본 연구는 Hord 등이 개발한 CBAM(관심에 기초한 교육과정 실행 모형)을 적용하여 제7차 교육과정에서의 조리실습 교육에 대한 교사의 관심도, 실행 수준. 실행 형태 및 지원 요구도를 알아봄으로써. 변화하는 시대와 새로운 교육과정에 맞는 조리실습 교육이 이루어질 수 있도록 질적 개선을 위한 기초 자료를 제공하는데 그 목적을 두었다. 5대 도시 중 고둥학교의 가정과 교사 500명을 대상으로 질문지를 우편 발송하였고, 회수된 193부 중 부실 기재된 6부를 제외한 187부를 SPSS/win 10.0 프로그램을 이용하여 빈도와 백분율, 평균, 표준편차, $X^2$ 분석, one-way ANOVA, 독립표본 t-test를 실시하였으며, 연구 결과를 요약하면 다음과 같다. 첫째, 조리실습 교육에 대한 가정과 교사의 관심 단계는 대체로 무관심 상태인 지각적 단계 즉 변화 초기에 해당하는 낮은 관심 수준에 머물고 있는 것으로 나타났다. 둘째, 조리실습 교육의 실행 수준에 있어 조리실습을 실행하지 않는 수준은 없었고, 일상화의 단계가 가장 높았으며, 대체로 초기 단계로 나타났던 관심도와 달리, 실행 수준은 비교적 높은 특징을 보였다. 셋째. 제7차 교육과정 조리실습의 실행 형태를 알아본 결과, 전체적으로 약 30%의 교사가 제7차 교육과정과 전혀 부합되지 않는 실행을 하고 있는 것으로 나타났다. 목표와 내용 영역은 이상적인 실행 형태의 비율이 높았지만, 교수 학습방법과 교수 학습 자료, 평가 영역에서는 전혀 부합되지 않거나 부분적으로 부합되는 실행 형태가 높았다. 특히, 전혀 부합되지 않는 형태가 가장 높고 완전 부합 형태가 가정 적게 실행되고 있는 교수 학습방법 영역에 있어서 보다 많은 지원이 있어야 할 것으로 생각된다. 넷째, 조리실습 교육에서의 지원 요구도를 알아본 결과, 전반적으로 많은 지원을 원하고 있는 것으로 나타났다. 지원적 분위기 조성 중 설비 제공 지원에 대한 요구도가 가장 높았고, 다음이 재정 확보 및 실습비 지원으로 나타났다.

  • PDF

질소 플라즈마의 화장품 가능성 평가 (Evaluation of the Potential of Nitrogen Plasma to Cosmetics)

  • 이소민;정소영;;허효진;차병선;;이상훈;이미기;빈범호;곽병문
    • 대한화장품학회지
    • /
    • 제48권3호
    • /
    • pp.189-196
    • /
    • 2022
  • 플라즈마란 고체, 액체, 기체에 이은 "4번째 상"으로서 이온화된 기체를 의미한다. 주로 용접과 네온사인에 응용 및 사용되어 왔으나, 최근 암 치료 등 의료 분야에도 적용되고 있으며, 피부에서는 콜라겐 생성 촉진, 피부 톤 개선, 피부 유해균 사멸 등 다양한 효과가 보고되고 있다. 본 연구는 대기의 주성분인 질소를 활용한 화장품 제조용 플라즈마 기기를 통해 질소 플라즈마 활성종 중, 추적 평가가 용이한 nitric oxide (NO)의 양을 측정하여 플라즈마의 양적/질적 평가를 진행하였다. 효율적인 플라즈마 처리를 위해 sinking과 non sinking 법을 활용한 주입 방법을 시도한 결과, non sinking 법을 활용한 제형의 근접 처리가 효과적임을 확인할 수 있었다. 나아가 토너와 앰플을 화장품 제형으로 선택하여 NO 플라즈마 주입 후 제형의 성상 및 주입한 플라즈마의 상태 변화를 관찰하였다. 두 제형에서 NO 플라즈마의 주입 성공량은 토너가 앰플보다 약 2 배 가량 높았으며, 시간에 따라 점진적으로 감소하여 일주일 후, 소실되는 것이 확인되었다. 사용된 질소 플라즈마는 저온(4 ℃), 실온(25 ℃), 고온(37 ℃, 50 ℃) 조건에서 토너와 앰플 제형의 안정도에 영향을 미치지 않는 것을 확인하였다. 종합적으로, 본 연구는 질소 플라즈마의 화장품 가능성을 제시하고 있으며 주입된 플라즈마의 안정성 확보의 중요성을 시사하고 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF