• Title/Summary/Keyword: component mode method

Search Result 293, Processing Time 0.118 seconds

Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple (주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.

Development of Automatic Reactor Internal Vibration Monitoring System Using Fuzzy Peak Detection and Vibration Mode Decision Method

  • Kang, Hyun-Gook;Seong, Poong-Hyun;Park, Heui-Youn;Lee, Cheol-Kwon;Koo, In-Soo
    • Nuclear Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.8-16
    • /
    • 1998
  • In this work a method to detect the vibrational peak and to decide the vibrational mode of detected peak for core internal vibration monitoring system which is particularly concerned on the core support barrel (CSB) and fuel assemblies is developed. Flow induced vibration and aging process in the reactor internals cause unsoundness of the internal structure. In order to monitor the vibrational status of core internal, signals from the ex-core neutron detectors are transformed into frequency domain. By analyzing transformed frequency domain signal, an analyst can acquire the information on the vibrational characteristics of the structures, i.e., vibration frequencies of each component, vibrational level, modes of vibration, and the causes of the abnormal vibration, if any. This study is focused on the development of the automated monitoring system. Several methods are surveyed to define the peaks in power spectrum and fuzzy theory is used to automatic detection of the vibrational peaks. Fuzzy algorithm is adopted to define the modes of vibration using the peak values from fuzzy peak recognition, phase spectrum, and coherence spectrum.

  • PDF

Fixed speed wind power generation system modeling and transient state stabilization method using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 고정속 풍력발전시스템 모델링 및 과도상태 안정화기법)

  • Kim, Young-Ju;Park, Dae-Jin;Ali, Mohd Hasan;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1178-1179
    • /
    • 2008
  • This paper describes a modeling of fixed speed wind power generation system which comprise of wind turbine, generator and grid. The wind turbine is based on MOD-2, which is IEEE standard wind turbine, and includes a component using wind turbine characteristic equation. Fixed speed induction generator is directly connected to grid, so the variation of wind speed has effects on the electrical torque and electrical output power. Therefore the power control mode pitch control system is necessary for aerodynamic control of the blades. But the power control mode does not operate at the fault condition. So it is required some methods to control the rotor speed at transient state for stabilization of wind power system. In this paper, simulation model of a fixed speed wind power generation system based on the PSCAD/EMTDC is presented and implemented under the real weather conditions. Also, a new pitch control system is proposed to stabilize the wind power system at the fault condition. The validity of the stabilization method is demonstrated with the results produced through sets of simulation.

  • PDF

Method for Designing Impedance Network at Quasi Z-Source Inverter (Quasi Z-소스 인버터의 임피던스 네트워크 설계방법)

  • Yang, J.H.;Chun, T.W.;Lee, H.H.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.223-224
    • /
    • 2011
  • This paper presents the method to design the inductor and capacitor value considering the ripple component that may be generated by three operating states of the Quasi Z source inverter at the impedance network. Based on the analysis of each operation mode, the equations of the capacitor voltage and inductor current are derived. In order to simplify the design processing, design equations of the impedance network are derived where the capacitor voltage and inductor current are lineared. The validity of the design method is verified with the simulation result using PSIM.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulsed Load in DC Microgrid (직류 마이크로그리드에서 펄스형 부하 보상용 슈퍼커패시터 무순단 제어법)

  • Dam, Hung D.;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.4
    • /
    • pp.265-272
    • /
    • 2018
  • This paper proposes a new control method for the supercapacitor (SC) to compensate the pulsed load and to enhance the power quality of the DC microgrid. By coordinating the operating frequency, the SC is controlled to handle the surge current, while the low-frequency current component is dealt with by the remaining sources in the system. The operation mode of the SC unit is automatically changed based on the state of charge and DC bus voltage level. Meanwhile, the mismatch in the power demand is covered by the SC unit by regulating the DC bus voltage level. The effectiveness of the proposed method is verified experimentally by the prototype with two distributed generators and one SC unit.

A Sinkhole Detection Method based on Incremental Learning in Wireless Ad Hoc Networks

  • Kim, Ki-Sung;Kim, Se-Hun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.377-382
    • /
    • 2007
  • Mobile ad hoc network(MANET) is a kind of wireless network which has no infrastructure. Each component node of MANET can move freely and communicate based on wireless peer to peer mode. Because of its vulnerable routing protocols, MANET is exposed to many kinds of attacks. A sinkhole attack is one of the representative attacks in MANET caused by attempts to draw all network traffic to a sinkhole node. This paper focuses on the sinkhole problem on Dynamic Source Routing(DSR) protocol in MANET. To detect the sinkhole node, we extract several useful sinkhole indicators through analyzing the sinkhole problem, then propose an efficient detection method based on an incremental learning algorithm. The simulation results show that the proposed method is effective and reliable for detecting sinkhole intrusion.

  • PDF

Failure Risk Evaluation to Flood for Irrigation Reservoirs (농업용 저수지의 홍수 취약성 지수 개발)

  • Jang, Min-Won;Choi, Jin-Yong;Lee, Jun-Goo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.135-138
    • /
    • 2005
  • This study began to establish a risk evaluation method for irrigation reservoirs under the overtopping failure mode. To define the risk, reliability analysis was performed using time series of reservoir flood inflow and spillway outflow. The former was defined as a load and the latter was the resistance component. The method results in failure probability, which is calculated by convolution multiplication between probability distribution functions of both components. The proposed method was applied to 3 reservoir sites and each failure probability was determined as 0.0012, 0.00001, and 0.000001 respectively.

  • PDF

Method for Designing Parameters of Impedance Network at Quasi Z-Source Inverter (Quasi Z-소스 인버터의 임피던스 네트워크 파라미터 설계방법)

  • Yang, J.H.;Chun, T.W.;Lee, H.H.;Kim, H.G.;Nho, E.C.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.203-204
    • /
    • 2012
  • This paper presents the method to design the inductor and capacitor value considering the ripple component that may be generated by three operating states of the Quasi Z-source inverter at the impedance network. Based on the analysis of each operation mode, the equations of the capacitor voltage and inductor current are derived. In order to simplify the design processing, design equations of the impedance network are derived where the capacitor voltage and inductor current are lineared. The validity of the design method is verified with the simulation result using PSIM and experimental result using 32-bit DSP.

  • PDF

Structural Dynamics Modification using Reduced Model for Having Non-matching Nodes (불일치 절점을 가지는 경우의 축약된 모델을 이용한 동특성 변경법)

  • Kang, Ok-Hyun;Park, Youn-Sik;Park, Young-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.830-833
    • /
    • 2005
  • SDM(Structural Dynamics Modification) is to improve dynamic characteristics of a structure, more specifically of a base structure, by adding or deleting auxiliary(modifying) structures. In this paper, I will focus on the optimal layout of the stiffeners which are attached to the plate to maximize 1st natural frequency. Recently, a new topology method was proposed by yamazaki. He uses growing and branching tree model. I modified the growing and branching tree model. The method is designated modified tree model. To expand the layout of stiffeners, I will consider non-matching problem. The problem is solved by using local lagrange multiplier without the mesh regeneration. Moreover The CMS(Component mode synthesis) method is employed to reduce the computing time of eigen reanalysis using reduced componet models.

  • PDF

Approximate Response of a Non-linear Vibration Isolation System Using the Harmonic Balance Method (하모닉 밸런스법을 이용한 비선형 진동절연 시스템의 근사적 응답)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.124-129
    • /
    • 2018
  • A non-linear vibration isolation system which is composed of a non-linear spring and a linear damper was proposed in past research. When the support of the isolation system is excited harmonically, the response component of the isolation system mass at the excitation frequency has been calculated approximately using the harmonic balance method. The response was approximated by a single mode, and the result was compared with a numerical result which is assumed as an accurate one. Next, the response was approximated by two modes, and the result was compared with the former one.