• Title/Summary/Keyword: complex segment

Search Result 167, Processing Time 0.023 seconds

Repair of Complex Cardiac Anomaly Associated with Congenital Tracheal Stenosis -1 Case Report- (선천성 기관 협착증을 동반한 복잡 심기형의 완전 교정술 -1예 보고-)

  • Park, Jeong-Jun;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.88-91
    • /
    • 1997
  • Congenital long-segment tracheal stenosis with complex cardiac anomaly has generally been regarded as a fatal disease This report described the successful concomitant repair of unexpected congenital tracheal stenosis and complex cardiac anomaly with the use of edrdiopulmonary bypass. The patient was a 3-month-old girl with coarctation of aorta, V D, and PDA. The presence of tracheal stenosis was not discovered until when difficulty with endotracheal intubation was encountered at operating room. Thus, we decided concomitant repair of both lesions and performed anterior pericardial tracheoplasty combined with one stage repair of coarctation of aorta, VSD, and PDA under the cardiopulmonary bypass. The patient is doing well without any signs of complication at present, 2 years and 1 month after the operation.

  • PDF

Effects of Mitochondrial DNA Polymorphism on Growth Traits of Hanwoo (mt DNA 다형이 한우 성장에 미치는 영향)

  • Jeon, G.J.;Chung, H.Y.;Choi, J.G.;Lee, M.S.;Chung, Y.H.;Lee, C.W.;Park, J.J.;Ha, J.M.;Lee, H.K.;Na, K.J.
    • Journal of Embryo Transfer
    • /
    • v.18 no.3
    • /
    • pp.227-235
    • /
    • 2003
  • 한우의 mt DNA cytochrome oxidase subunit I, II, 및 III complex지역의 유전적 다형현상을 제한효소를 이용하여 검출하였다. PCR primer 6종에 대하여 20가지 제한효소를 처리하였으며, Pst I, Pvu II, Rsa I, Eco RI, Bgl II, and Msp I 제한효소를 사용하여 유전적 변이를 검출하였다. 검출된 변이체와 한우의 성장과의 관련성을 조사한 결과 cytochrome oxidase subunit III complex 지역의 유전염기서열을 근거로 제작한 primer Mt9 좌위에서 제한효소 PvuII를 이용한 절단형과 체중형질 인 WT15(P<0.05) 및 WT18(P<0.01)에서 고도의 유의성이 관찰되었다. 아울러 , Mt9-Pvu II(P=0.07), Mt6-Bgl II(P=0.05), and Mt8-Rsa I(P=0.05) 좌위 또한 WT9, WTl5, and WT15에서 각각 통계적 유의성이 관찰되었다. 따라서 본 결과는 cytochrome oxidase subunit III complex segments가 candidate gene으로서 기초적 유전정 보 제공은 물론 유전적 개량을 위해 사용될 수 있을 것으로 사료된다.

Performance evaluation of vessel extraction algorithm applied to Aortic root segmentation in CT Angiography (CT Angiography 영상에서 대동맥 추출을 위한 혈관 분할 알고리즘 성능 평가)

  • Kim, Tae-Hyong;Hwang, Young-sang;Shin, Ki-Young
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.2
    • /
    • pp.196-204
    • /
    • 2016
  • World Health Organization reported that heart-related diseases such as coronary artery stenoses show the highest occurrence rate which may cause heart attack. Using Computed Tomography angiography images will allow radiologists to detect and have intervention by creating 3D roadmapping of the vessels. However, it is often complex and difficult do reconstruct 3D vessel which causes very large amount of time and previous researches were studied to segment vessels more accurate automatically. Therefore, in this paper, Region Competition, Geodesic Active Contour (GAC), Multi-atlas based segmentation and Active Shape Model algorithms were applied to segment aortic root from CTA images and the results were analyzed by using mean Hausdorff distance, volume to volume measure, computational time, user-interaction and coronary ostium detection rate. As a result, Extracted 3D aortic model using GAC showed the highest accuracy but also showed highest user-interaction results. Therefore, it is important to improve automatic segmentation algorithm in future

Measurement of Target Objects Based on Recognition of Curvature and Plane Surfaces using a Single Slit Beam Projection (슬릿광 투영법을 이용한 곡면과 평면의 식별에 의한 대상물체의 계측)

  • Choi, Yong-Woon;Kim, Young-Bok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.5
    • /
    • pp.568-576
    • /
    • 1999
  • Using a laser sheet beam projector combined with a CCD-Camera, an efficient technique to recognize complex surface of curvature and lane has been demonstrated for the purpose of mobile robot navigation. In general, obstacles of indoor environments in the field of SLIT-RAY plane are captured as segments of an elliptical arc and a line in the camera image. The robot has been capable of moving along around the obstacle in front of it, by recognizing the original shape of each segment with the differential coefficient by means of least squares method. In this technique, the imaged pixels of each segment, particularly elliptical arc, have been converted into a corresponding circular arc in the real-world coordinates so as to make more feasible the image processing for the position and radius measurement than conventional way based on direct elliptical are analyses. Advantages over direct elliptical cases include 1) higher measurement accuracy and shorter processing time because the circular arc process can reduce the shape-specifying parameters, 2) no complicated factor such as the tilt of elliptical arc axis in the image plane, which produces the capability to find column position and radiua regardless of the camera location . These are essentially required for a mobile robot application. This technique yields an accuracy less than 2cm for a 28.5cm radius column located in the range of 70-250cm distance from the robot. The accuracy obtained in this study is sufficient enough to navigate a cleaning robot which operates in indoor environments.

  • PDF

A molecular Genetic Variation among Intra-poplations of Korean shiner, Coreoleuciscus splendidus Mori (Cyprinidae) (한국산 쉬리, Coreoleuciscus splendidus (잉어과)의 종내 집단간 분자 유전 변이)

  • Song, Ho-Bok;Park, Gab-Man
    • Korean Journal of Ichthyology
    • /
    • v.18 no.2
    • /
    • pp.78-86
    • /
    • 2006
  • We examined the genetic diversity in intra-populations of Korean shiner, Coreoleuciscus splendidus, in six major rivers (Bukhan, Namhan, Geum, Osipcheon, Nakdong and Seomjin river) of Korea based on two different mitochondrial genes, the mitochondrial cytochrome b and the 16S rRNA. Analysis of sequence variation in a 657-bp segment of the mitochondrial cytochrome b gene revealed deep divergence among populations (98.2~99.9%) and high genetic diversity from geographically isolated populations. Intra-specific variation in this 697-bp segment of the 16S rRNA gene sequences was very low and nearly identical. Six isolate populations of C. splendidus showed a high similarity (97.7%~99.7%). This result may be indicative of a complex history of connection and isolation of the rivers in the Korea peninsula.

Iatrogenic Ureteral Injury: When and How to Treat? (의인성 요관손상: 언제, 어떻게 치료할 것인가?)

  • Seo, Kang Il;Lee, Jong Bouk
    • Journal of Trauma and Injury
    • /
    • v.21 no.1
    • /
    • pp.8-14
    • /
    • 2008
  • Iatrogenic ureteral injury is a complication that can occur during a variety of pelvic or abdominal surgeries. The most frequent causes are gynecological ones, followed by colon and vascular surgeries. Management of ureteric injury depends on the time of diagnosis and the severity of organ damage. Injuries diagnosed intraoperatively should be treated immediately. Occasionally, intraoperative ureteral injury is overlooked, and symptoms of the late diagnosis of ureteral injury are usually nonspecific; therefore, the diagnosis is delayed for days or weeks postoperatively. Management of injuries diagnosed postoperatively is more complex. There are differing opinions on whether an initial conservative or immediate operative intervention is the best line of action. Delayed repair is suggested on the grounds that it will reduce inflammation and tissue edema. However, many authors are in favor of early repair, perhaps because tissue planes are easier to find before fibrosis becomes too dense. Ureteral injuries occurring at the level of the pelvic brim should be best managed with an end-to-end anastomosis, preferably around a ureteric stent. More distal injuries also should be ideally managed with an end-to-end anastomosis, after excision of the crushed or compromised segments. However, if the remaining distal segment is short, ureteral reimplantation is the procedure of choice. The Boari flap technique for ureteral reimplantation is invaluable in cases with a short proximal segment. Delayed recognition of iatrogenic ureteral injury may be associated with serious complications, so prompt recognition of ureteral injuries is important. Recognition of the injury before closure is the key to easy, successful, and complications-free repair. Increased awareness of the risk for ureteral damage during certain operative maneuvers is vital to prevent injury, and to decrease the incidence of iatrogenic injury. A sound knowledge of abdominal and pelvic anatomy is the best prevention.

A Biomechanical Comparison of Intralaminar C7 Screw Constructs with and without Offset Connector Used for C6-7 Cervical Spine Immobilization : A Finite Element Study

  • Qasim, Muhammad;Hong, Jae Taek;Natarajan, Raghu N.;An, Howard S.
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.331-336
    • /
    • 2013
  • Objective : The offset connector can allow medial and lateral variability and facilitate intralaminar screw incorporation into the construct. The aim of this study was to compare the biomechanical characteristics of C7 intralaminar screw constructs with and without offset connector using a three dimensional finite element model of a C6-7 cervical spine segment. Methods : Finite element models representing C7 intralaminar screw constructs with and without the offset connector were developed. Range of motion (ROM) and maximum von Mises stresses in the vertebra for the two techniques were compared under pure moments in flexion, extension, lateral bending and axial rotation. Results : ROM for intralaminar screw construct with offset connector was less than the construct without the offset connector in the three principal directions. The maximum von Misses stress was observed in the C7 vertebra around the pedicle in both constructs. Maximum von Mises stress in the construct without offset connector was found to be 12-30% higher than the corresponding stresses in the construct with offset connector in the three principal directions. Conclusion : This study demonstrated that the intralaminar screw fixation with offset connector is better than the construct without offset connector in terms of biomechanical stability. Construct with the offset connector reduces the ROM of C6-7 segment more significantly compared to the construct without the offset connector and causes lower stresses around the C7 pedicle-vertebral body complex.

Feature Extraction based on Auto Regressive Modeling and an Premature Contraction Arrhythmia Classification using Support Vector Machine (Auto Regressive모델링 기반의 특징점 추출과 Support Vector Machine을 통한 조기수축 부정맥 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong;Kim, Joo-man;Kim, Seon-jong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2019
  • Legacy study for detecting arrhythmia have mostly used nonlinear method to increase classification accuracy. Most methods are complex to process and manipulate data and have difficulties in classifying various arrhythmias. Therefore it is necessary to classify various arrhythmia based on short-term data. In this study, we propose a feature extraction based on auto regressive modeling and an premature contraction arrhythmia classification method using SVM., For this purpose, the R-wave is detected in the ECG signal from which noise has been removed, QRS and RR interval segment is modelled. Also, we classified Normal, PVC, PAC through SVM in realtime by extracting four optimal segment length and AR order. The detection and classification rate of R wave and PVC is evaluated through MIT-BIH arrhythmia database. The performance results indicate the average of 99.77% in R wave detection and 99.23%, 97.28%, 96.62% in Normal, PVC, PAC classification.

Studies on electrocardiogram of the normal Korean native cattle I. Standard limb leads (정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) I. 표준지유도(標準肢誘導))

  • Choi, In-hyuk;Jung, In-sung;Kim, Nam-soo;Suh, Doo-seok
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.719-734
    • /
    • 1993
  • The electrocardiographic(ECG) parameters on the standard limb leads in the normal Korean native cattle have been measured with a 3 channel Electrocardiograph built in a computed analysis. The study was conducted on the animals 98 heads of mean age of 17.7 months. Conduction parameters, waves, intervals and segments have been recorded. The recordings were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate was recorded by the Electrocardiogram which were a mean of $80.4{\pm}11.6beats/min$. And the younger had a higher heart rate than the older one. Average conduction times in the RP, the QRS complex and the QTc interval recorded $166.7{\pm}23.1msec.$, $79.7{\pm}8.8msec.$ and $395.5{\pm}30.4msec.$, in the P and T wave duration recorded $70.1{\pm}13.5msec.$ and $97.6{\pm}16.9msec.$, and in the PR and ST segment duration recorded $97.9{\pm}23.5msec.$ and $173.9{\pm}40.3msec.$, respectively. The wave forms in each lead observed various types. The amplitudes of wave type showed the highest frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of the positive type showed the frequency of 65.3%, 82.7% and 52.0% in leads I, II and III that were $103.1{\pm}47.8{\mu}V$, $115.2{\pm}37.3{\mu}V$ and $67.4{\pm}26.9{\mu}V$, and it showed the frequency of 54.1% and 85.7% in the leads aVL and aVF that were $63.7{\pm}23.0{\mu}V$, $88.0{\pm}83.6{\mu}V$, respectively. Average amplitude of the negative type showed the frequency of 78.6% in lead aVR which was $99.3{\pm}38.0{\mu}V$. 2. Average amplitude of the QRS complex were from $362.8{\pm}177.7{\mu}V$ to $532.8{\pm}253.9{\mu}V$(mean of $449.1{\pm}57.2{\mu}V$) that in all leads except lead I were manifested the Low-Voltage QRS complex(below 0.5mV). Average amplitudes of each wave type in the QRS complex aere $-50.2.4{\pm}258.2{\mu}V$ and $-428.6{\pm}195.1{\mu}V$ in the QS groups type that showed a frequency of 66.3%, 70.4% in the leads I and aVL, were $451.1{\pm}20.4.0{\mu}V$, $387.6{\pm}175.8{\mu}V$ and $299.3{\pm}146.5{\mu}V$ in the R groups type that showed a frequency of 48.0%, 53.1% and 34.7% in the leads III, aVR and aVF, and were $-307.5{\pm}180.3{\mu}V$, $201.4{\pm}77.2{\mu}V$ in the QR wave type which showed a frequency of 39.8% in lead II, respectively. 3. In T wave, amplitude of the positive type showed the frequency of 50.0%, 82.7%, 51.0% and 57.1% in leads II, III aVR and aVF which were $214.9{\pm}115.6{\mu}V$, $188.5{\pm}119.3{\mu}V$, $191.0{\pm}93.7{\mu}V$ and $165.7{\pm}91.9{\mu}V$, and the negative type showed a frequecny of 66.3% and 72.5% in leads I and aVL. that were $221.3{\pm}112.5{\mu}V$, $-173.6{\pm}86.7{\mu}V$, respectively. 4. Amplitude of ST segment in leads I, II and III were a mean of $-12.2{\pm}37.2{\mu}V$, $17.5{\pm}42.6{\mu}V$ and $28.3{\pm}40.4{\mu}V$, in leads aVR, aVL and aVF were $-3.9{\pm}32.5{\mu}V$, $-15.9{\pm}35.6{\mu}V$ and $26.2{\pm}37.5{\mu}V$, respectively.

  • PDF

Computational Hemodynamics in the Intracranial Aneurysm Model (뇌동맥류 모델에 대한 혈류역학 해석)

  • Seo, Taewon;Byun, Jun Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.927-932
    • /
    • 2013
  • The intracranial aneurysm model is extracted based on the Computed Tomography (CT) scan images. Computational fluid dynamics simulations were conducted under both steady and realistic flow conditions in ANSYS-FLUENT. The minimum wall shear stress in the intracranial aneurysm tended to occur in the aneurysmal region. The magnitude of wall shear stress along inner wall of the curvature in the right M1 segment of middle cerebral artery is approximately 20 times higher than that along both the proximal and distal walls. However, the magnitudes of the wall shear stress at the aneurysm region were considerably low. The blood flow has the complex distribution in the aneurysmal region during the systolic period. Complex helical flow patterns are observed inside the aneurysm. Through an analysis of the hemodynamic characteristics, one may predict the rupture of the cerebral aneurysms.