• Title/Summary/Keyword: complex sampling

Search Result 437, Processing Time 0.03 seconds

Pollutant Loading Estimates from Watershed by Rating Curve Method and SWMM

  • Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.5
    • /
    • pp.419-425
    • /
    • 2000
  • Rating curve method and SWMM (Storm Water Management Model) were applied to estimate pollutant loading from Hwa-Ong watershed in Kyunggi-Do. Rating curves were derived from sampling sites and applied to the whole watershed. SWMM version 4.4 was calibrated by field data of sampling sites and applied to the whole watershed. The pollutant loading estimated by rating curve was slightly higher than the one by SWMM, but the difference was not significant considering diffuse pollution characteristics of wide variation. Land use effect of the subcatchments could not be incorporated logically in rating curve method and difficulty in extrapolation was experienced, therefore, the estimate by rating curve method was thought to be less confident. SWMM was satisfactory in estimation of pollution loading, and its great flexibility worked well to describe complex nonurban land uses. Neither of them could exactly describe complex natural phenomena, but SWMM was preferred in this study due to its flexibility and logical hydrologic processes including land use effects. Use of reasonable watershed model rather than rating curve method for watershed pollutant loading estimate can be more practical and is recommended.

  • PDF

Accurate Closed-Form Green′s Function for the Analysis of coplanar Waveguides (코플래너 도파로 해석을 위한 정확한 Closed-Form 그린함수)

  • Gang, Yeon-Deok;Lee, Taek-Gyeong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.11
    • /
    • pp.23-31
    • /
    • 2000
  • In the layered medium, infinite Sommerfeld integral must be evaluated to calculate a space domain Green's function. The complex image method and the two-level method provide rapid calculation and accurate solutions in the near-field region. However, in the intermediate and far-field region, the solutions are inaccurate due to the deformation of the sampling contour. In this paper, we propose a method to calculate an accurate closed-form Green's function for coplanar structure by sampling data on the real axis.

  • PDF

Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device (휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발)

  • Lee, Eun-Mi;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.

A Study on the properties of the Multiensemble Sampling method (Multiensemble Sampling 방법의 속성에 대한 연구)

  • Han, Kyu-Kwang
    • The Journal of Natural Sciences
    • /
    • v.15 no.1
    • /
    • pp.11-34
    • /
    • 2005
  • It is no exaggeration to say that the productivity of a research using computer simulations on complex molecular systems like biomolecules depends on the ability of the sampling algorithm to explore the relevant parts of configuration space. In this study, we investigate the properties on the mutiensemble sampling (MES) which is one of the solutions that surmount limitations of conventional sampling algorithms. Works for finding out practical systematic ways of using the MES efficiently to explore distantly separated regions in configuration space are performed. In this work, the more generalized form of weighting function for MES is used and 'cavity formation in water' is simulated using Monte Carlo. investigating the correlation of simulation parameters and the efficiency of the method, we propose a practical way of maximizing the power of the MES. We applied the way to 'cavity formation in water' and were able to explore the parts of configuration space relevant to cavities of radius from 0 to 5.6A in a single simulation.

  • PDF

A study of the hologram which records the interference of light with computer (컴퓨터로 빛의 간섭을 기록하는 홀로그램(CGH)의 특성 연구)

  • Lee, Jeong-Yeong;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.305-312
    • /
    • 2005
  • In this thesis, Lohmann's algorithm and FFT (fast Fourier transform) are used to synthesize binary-phase holograms. FFT computing is carried out for the calculation of complex wavefronts of $128{\times}128$ sampling points of an object that is numerically specified. Then using the Lohmann's algorithm, the amplitude and the phase of complex wavefronts are encoded in binary holograms on each sampling points. PC (personal computer) and laser printer are used to plot binary-phase holograms and CGH (computer generated holograms) films are obtained from this plot by photographic reduction. Holographic images of numerically specified objects are reconstructed from the He-Ne laser and the inverse Fourier optics system. We estimate the quality of holographic images according to the sampling number, application of random phase, amplitude clipping and bleaching the CGH film. We derive optimized conditions to reconstruct better holographic images and to reduce the speckle noise. FFT and Lohmann's algorithm are implemented with MS Visual BASIC 6.0 for the programming of binary-phase hologram.

  • PDF

Inappropriate Survey Design Analysis of the Korean National Health and Nutrition Examination Survey May Produce Biased Results

  • Kim, Yangho;Park, Sunmin;Kim, Nam-Soo;Lee, Byung-Kook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.46 no.2
    • /
    • pp.96-104
    • /
    • 2013
  • Objectives: The inherent nature of the Korean National Health and Nutrition Examination Survey (KNHANES) design requires special analysis by incorporating sample weights, stratification, and clustering not used in ordinary statistical procedures. Methods: This study investigated the proportion of research papers that have used an appropriate statistical methodology out of the research papers analyzing the KNHANES cited in the PubMed online system from 2007 to 2012. We also compared differences in mean and regression estimates between the ordinary statistical data analyses without sampling weight and design-based data analyses using the KNHANES 2008 to 2010. Results: Of the 247 research articles cited in PubMed, only 19.8% of all articles used survey design analysis, compared with 80.2% of articles that used ordinary statistical analysis, treating KNHANES data as if it were collected using a simple random sampling method. Means and standard errors differed between the ordinary statistical data analyses and design-based analyses, and the standard errors in the design-based analyses tended to be larger than those in the ordinary statistical data analyses. Conclusions: Ignoring complex survey design can result in biased estimates and overstated significance levels. Sample weights, stratification, and clustering of the design must be incorporated into analyses to ensure the development of appropriate estimates and standard errors of these estimates.

A sample survey design for service satisfaction evaluation of regional education offices (지역교육청 수요자 만족도조사를 위한 표본설계에 관한 연구)

  • Heo, Sun-Yeong;Chang, Duk-Joon
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.4
    • /
    • pp.669-679
    • /
    • 2010
  • A sample survey design is suggested for the service satisfaction evaluation of regional education offices based on the sample size of 2009 Gyeongnam regional education offices's customer satisfaction survey. The sample design is developed to fit the goal of evaluation of individual regional offices and allocate at least the minimum sample size to each city or county in Gyeongnam to achieve the goal of the survey. The population is stratified according to the regions and the types of schools, and the sample of schools is selected with proportional to the size of classes within each stratum. Finally, each sample student is selected according to two-stage cluster sampling within each sample school. Weighting averages, weighting totals and so on can be evaluated for analysis purposes. Their variance estimates can be evaluated using re-sampling methods like BBR, Jackknife, linearization-substitution methods, which are generally used for the data from a complex sample.

Sampling and Analysis of Acidic Air Pollutants Using an Annular Denuder System during the Summer Season in Chongju City (디누더 측정기를 이용한 여름철 청주시의 산성오염물질 측정과 분석)

  • 이학성;강병욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.441-448
    • /
    • 1996
  • The cyclone/annular denuder system/filter pack sampling system (ADS) was used to collect the acidic air pollutants in Chongju city. The data set was collected on nine different days with 24 hour sampling period from July 27 through August 27, 1995. The chemical species measured were $HNO_3, HNO_2, SO_2 and NH_3$ in the gas phase, and $PM_{2.5}(d_P<2.5 \mum), SO_4^{2-}, NO_3^- and NH_4^+$ in the particulate phase. Mean concentrations measured from this study were: $0.90 \mug/m^3 for HNO_3, 1.27 \mug/m^3 for HNO_2, 10.9 \mug/m^3 for SO_2, 4.82 \mug/m^3 for NH_3, 27.5 \mug/m^3 for PM_{2.5}, 5.24 \mug/m^3 for SO_4^{2-}, 1.22 \mug/m^3 for NO_3^-, and 1.64 \mug/m^3 for NH_4^+$. The fine particle $(PM_{2.5})$ mass measured for the ADS samples was slightly higher than the fine particle mass measured for the corresponding dichotomous sampler. For the wind coming from Chongju industrial complex the concentrations of acidic air pollutants measured were higher when compared with other directions. Specially, $SO_2 and PM_{2.5}$ concentrations for the wind coming from Chongju industrial complex were 3.6 and about 2 times, respectively, higher than those of other wind directions. High correlations were observed between $PM_{2.5} and fine particle's ion components $(r=0.82 with SO_4^{2-}, r=0.76 with NO_3^- and r=0.89 with NH_4^+). NH_4^+ and SO_4^{2-}$ was also highly correlated (r=0.97).

  • PDF

Environmental Impact Assessments along with Construction of Residential and Commercial Complex (주거단지 건설이 하천에 미치는 생태영향평가)

  • An, Kwang-Guk;Han, Jeong-Ho;Lee, Jae Hoon
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.631-648
    • /
    • 2012
  • The integrative ecological approaches of chemical assessments, physical habitat modelling, and multi-metric biological health modelling were applied to Gwanpyeong Stream within Gap-Stream watersheds to evaluate environmental impacts on the constructions of residential and commercial complex. For the analysis, the surveys conducted from 45 sites of reference streams within the Gap-Stream watershed and 3 regular sites during 2009 - 2010. Physical habitat health, based on the habitat model of Qualitative Habitat Evaluation Index(QHEI) declined from the headwaters(good - fair condition) to the downstream(poor condition). Chemical water quality, based turbidity and electric conductivity(EC), was degraded toward to the downstream, and especially showed abrupt increases, compared to the values of control streams(CS). Also, concentrations of chlorophyll-a in the downstreams were greater compared to the control stream(CS), indicating an eutrophication. Biological health conditions, based on the Index of Biological Integrity(IBI) using fish assemblages, averaged 19.3 which is judged as a fair condition by the biological criteria of the Ministry of Environment, Korea. The comparisons of model metric values in sensitive species and riffle-benthic species on the Maximum Species Richness Line(MSRL) of 45 reference streams indicated a massive disturbances in all sampling locations. Also, tolerance guild and trophic guild analyses suggest that dominances of tolerant species and omnivores were evident, indicating a biological degradation by habitat disturbances and organic matter pollutions. There was no distinct longitudinal variations of IBI model values from the headwater to the downstream in spite of slight chemical and habitat health gradients among the sampling sites. Overall, integrative ecological health(IEH) scores, based on the chemical, physical, and biological parameters, were low compared to the 45 reference streams due to physical and chemical disturbances of massive constructions of the residential and commercial complex. This stream, thus showed a tendency of typical urban streams which are disturbed in the chemical water quality, habitat structures, and biological integrity. Effective stream management plans and restoration strategies are required in this urban stream for improving integrative stream health.

Preparation of Metal-p-aminobenzyl-DOTA Complex Using Magnetic Particles for Bio-tagging in Laser Ablation ICP-MS

  • Yoon, S.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3665-3670
    • /
    • 2012
  • Metal-p-$NH_2$-Bn-DOTA (paraammionobenzyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid: ABDOTA) complex was synthesized and purified for bio-tagging to quantify biological target materials using laser ablation (LA)-ICP-MS. Since the preparation of a pure and stable tagging complex is the key procedure for quantification, magnetic particles were used to purify the synthesized metal-ABDOTA complex. The magnetic particles immobilized with the complex attracted to a permanent magnet, resulting in fast separation from free un-reacted metal ions in solution. Gd ions formed the metal-complex with a higher yield of 64.3% (${\pm}3.9%$ relative standard deviation (RSD)) than Y ions, 52.3% (${\pm}2.5%$ RSD), in the pH range 4-7. The complex bound to the magnetic particles was released by treatment with a strong base, of which the recovery was 81.7%. As a reference, a solid phase extraction (SPE) column packed with Chelex-100 resin was employed for separation under similar conditions and produced comparable results. The tagging technique complemented polydimethylsiloxane (PDMS) microarray chip sampling in LA-ICP-MS, allowing determination of small sample volumes at high throughputs. For application, immunoglobulin G (IgG) was immobilized on the pillars of PDMS microarray chips and then tagged with the prepared Gd complex. IgG could then be determined through measurement of Gd by LA-ICP-MS. A detection limit of 1.61 ng/mL (${\pm}0.75%$ RSD) for Gd was obtained.