• Title/Summary/Keyword: complete contact

Search Result 213, Processing Time 0.021 seconds

Improvement of Electrical Conductivity of Transparent Conductive Single-Walled Carbon Nanotube Films Fabricated by Surfactant Dispersion

  • Lee, Seung-Ho;Kim, Myoung-Su;Goak, Jeung-Choon;Lee, Nae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.254-254
    • /
    • 2009
  • Single-walled carbon nanotubes (SWCNTs) have attracted much attention as promising materials for transparent conducting films (TCFs), thanks to their superior electrical conductivity, high mechanical strength, and complete flexibility. The CNT-based TCFs can be used in a variety of application fields as flexible, transparent electrodes, including touch panel screens, flexible electronics, transparent heaters, etc. First of all, this study investigated the effect of a variety of surfactants on the dispersion of SWCNTs in an aqueous solution. Following the optimization of the dispersion by surfactants, flexible TCFs were fabricated by spraying the CNT suspension onto poly(ethylene terephthalate) (PET) substrates. The sheet resistances of the TCFs having different surfactants were investigated with treatment in nitric acid ($HNO_3$) whose concentration and period of treatment time were varied. It seems that the $HNO_3$ removes the surfactants from and is simultaneously doped into the SWCNT network, reducing the contact resistance between CNTs. TCFs were characterized by UV-VIS spectroscopy, thermogravimetric analyzer (TGA), scanning electron microscopy (SEM), and four-point probe.

  • PDF

The Development of Automatic Tool Change System for Polishing Robot and Windows-Environment Integration Program for Application (연마 로붓용 자동공구교환장치와 Windows환경에서의 통합용 프로그램 개발)

  • Park, Sang-Min;An, Jong-Seok;Song, Moon-Sang;Kim, Jae-Hee;Yoo, Bum-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.7
    • /
    • pp.147-154
    • /
    • 2003
  • An effective die-polishing robot system is developed. ATC (Automatic Tool Change), tool posture angle control, and robot program for polishing application are developed and integrated into a robotic system that consists of a robot, pneumatic grinding tool, and grinding abrasives (papers and special films). ATC is specifically designed to exchange whole grinding tool set for complete unmanned operation. A tool posture angle control system is developed for the tools to maintain a specified skew angle rather than right angle on the surface for best finishing results. A PC and the robot controller control ATC and tool posture angle. Also, there have been more considerations on enhancing the performance of the system. Elastic material is inserted between the grinding pad and the holder for better grinding contact. Robot path data are generated automatically from the NC data of previous machining process.

Hand-hygiene Compliance of Child Care Teachers through Observation Method (관찰법을 활용한 보육교사의 손위생 이행도)

  • Hwang, A-reum;Jeong, Ihnsook
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.19 no.1
    • /
    • pp.71-83
    • /
    • 2018
  • Background & objectives: This study was aimed to identify the hand hygiene (HH) compliance and related factors among teachers working at child day care centers. Method: This study was done with 44 teachers working at home child day care center in Changwon. Data on hand hygiene compliance was measured using direct observation method from July to December, 2016 with structured observation sheet. Collected data was analyzed by descriptive statistics, and t-test or ANOVA using SPSS Statistics version 23.0. Result: Complete HH compliance rate was 54.0%, the highest in 'before having meals' (81.6%) and the lowest in 'after having meals' (25.8%). However, incomplete HH compliance rate was 34.5%, the highest in 'after contact with secretions' (47.8%) and the lowest in 'before having meals' (18.4%). The HH rate was related with working experience. Conclusion: The HH compliance rate among child care teachers was not satisfactory. About one quarter of child care teachers have taken hand hygiene related training. Therefore, child care teachers should be encouraged to participate in hand hygiene related education program regularly.

Catalytic Combustion Characteristics of Hydrogen-Air Premixture in a Millimeter Scale Monolith Coated with Platinum (밀리미터 스케일 촉매 연소기에서의 수소-공기 예혼합 가스의 촉매 연소 특성)

  • Choi, Won-Young;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.1
    • /
    • pp.20-26
    • /
    • 2005
  • In the present study, catalytic combustion of hydrogen-air premixture in a millimeter scale monolith coated with Pt catalyst was investigated. As the combustor size decreases, the heat loss increases in proportion with the inverse of the scale of combustion chamber and combustion efficiency decreases in a conventional type of combustor. Combustion reaction assisted by catalyst can reduce the heat loss by decreasing the reaction temperature at which catalytic conversion takes place. Another advantage of catalytic combustion is that ignition is not required. Platinum was coated by incipient wetness method on a millimeter scale monolith with cell size of $1{\times}1mm$. Using this monolith as the core of the reaction chamber, temperatures were recorded at various locations along the flow direction. Burnt gas was passed to a gas chromatography system to measure the hydrogen content after the reaction. The measurements were made at various volume flow rate of the fuel-air premixture. The gas chromatography results showed the reaction was complete at all the test conditions and the reacting species penetrated the laminar boundary layer at the honeycomb and made contact with the catalyst coated surface. At all the measuring locations, the record showed monotonous increase of temperature during the measurement duration. And the temperature profile showed that the peak temperature is reached at the point nearest to the gas inlet and decreasing temperature along the flow direction.

  • PDF

Lumbar burner and stinger syndrome in an elderly athlete

  • Wegener, Veronika;Stabler, Axel;Jansson, Volkmar;Birkenmaier, Christof;Wegener, Bernd
    • The Korean Journal of Pain
    • /
    • v.31 no.1
    • /
    • pp.54-57
    • /
    • 2018
  • Burner or stinger syndrome is a rare sports injury caused by direct or indirect trauma during high-speed or contact sports mainly in young athletes. It affects peripheral nerves, plexus trunks or spinal nerve roots, causing paralysis, paresthesia and pain. We report the case of a 57-year-old male athlete suffering from burner syndrome related to a lumbar nerve root. He presented with prolonged pain and partial paralysis of the right leg after a skewed landing during the long jump. He was initially misdiagnosed since the first magnet resonance imaging was normal whereas electromyography showed denervation. The insurance company refused to pay damage claims. Partial recovery was achieved by pain medication and physiotherapy. Burner syndrome is an injury of physically active individuals of any age and may appear in the cervical and lumbar area. MRI may be normal due to the lack of complete nerve transection, but electromyography typically shows pathologic results.

Correlation between anterior thigh pain and morphometric mismatch of femoral stem

  • Chung, Haksun;Chung, So Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.1
    • /
    • pp.40-46
    • /
    • 2020
  • Background: Postoperative pain occurring after hip arthroplasty has become common since the expanded use of cementless femoral stems. The characteristic pain develop in the anterolateral thigh area. This study aimed to predict anterior thigh pain based on the measurements of postoperative anteroposterior (AP) and lateral (Lat) radiographs of the hip joint. Methods: The present study included 26 patients (29 hips) who underwent total hip replacement or bipolar hemiarthroplasty between March 2010 and May 2016, whose complete clinical information was available. AP and Lat radiographs of the affected hip were taken on the day of surgery and 1 and 6 months postoperatively. Patients with improper radiographs were excluded. The distance from the femoral stem to the nearest cortical bone in the distal region of the stem was measured. The patient group with a visual analog scale (VAS) score of ≥6 points was designated as patients with anterior thigh pain. Results: Sex, age, weight, height, body mass index, and bone mineral density in the lumbar spine and femur did not have a significant effect on postoperative VAS scores (p>0.05). Presence of contact between the femoral stem and cortical bone was associated with postoperative anterior thigh pain. Conclusion: Hip AP and Lat radiographs are usually taken to confirm fixation and alignment of the femoral stem after hip arthroplasty. The measurement method introduced in this study can be utilized for predicting anterior thigh pain after hip arthroplasty.

Nursing Needs of the Parents of Infants in Neonatal Intensive Care Unit (신생아집중치료실 입원 환아 부모의 간호요구)

  • Park, Ji-Sun;Bang, Kyung-Sook
    • Journal of East-West Nursing Research
    • /
    • v.20 no.2
    • /
    • pp.136-144
    • /
    • 2014
  • Purpose: The purposes of this study were to identify the perceived nursing needs and the differences by general characteristics of parents of infants in a neonatal intensive care unit (NICU) and to provide useful evidences developing a new intervention for family-centered care in NICU. Methods: A convenience sample of 121 parents of infants in NICU was used and the participants asked to complete the Korean version of NICU Family Needs Inventory (NFNI) from April to May, 2014. Data were analyzed using descriptive statistics, t-test and ANOVA. Results: The participants reported high average score in the perceived nursing needs. In subscales, needs for assurance rated highest score and needs for information, proximity, support, and comfort were followed. Mothers reported higher nursing needs score than fathers except the subscale of support. Conclusion: The findings suggest that nurses in NICU actively provide information about treatment, nursing, results of laboratory tests, and current status to give reassurance to parents. Not only providing informational support of parents of NICU infants, but also finding methods to contact to parents is necessary. In addition, nurses need to provide optimized intervention in current healthcare system and hospital environment.

TREATMENT OF MANDIBLE FRACTURES USING BIOABSORBABLE PLATES: PRELIMINARY STUDY (생흡수성판을 이용한 하악골 골절의 치료 : 일차보고)

  • Kim, Young-Kyun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.6
    • /
    • pp.570-575
    • /
    • 2001
  • This study evaluated the short-term outcome of treating fractures of the mandible with bioabsorbable plates. Thirty-four fractures of the mandible in 27 patients were treated by open reduction and internal fixation using bioabsorbable plates and 2.4-mm, 2.0-mm, and 1.5-mm pre-tapped screws. The duration of intermaxillary fixation ranged from 0 to 23 days, with a mean of 5.3 days. Patients were evaluated for complications during the follow-up period, which ranged from 2 to 18 months. Five patients(18.5%) experienced complications. These included infection (four patients), and premature occlusal contact(one patient). Except for one case, all complications were minor and adequately managed with incision and drainage, elastic traction, and medication. Delayed infection (osteomyelitis) developed in a symphysis fracture and was treated by saucerization and antibiotics. The fracture line subsequently showed complete consolidation. Bioabsorbable plates can be selectively used for internal fixation in mandibular fractures with the advantage that they do not need to be removed.

  • PDF

A geometrical review on the wear of rail and KTX wheel (레일과 차륜의 마모에 대한 기하학적 검토)

  • ;;;;R. Farabet
    • Proceedings of the KSR Conference
    • /
    • 2000.11a
    • /
    • pp.442-449
    • /
    • 2000
  • Before the complete construction of new high-speed line between Seoul and Pusan, KTX is going to operate on both new high-speed line between Seoul and Daegu and electrified conventional lines between Daegu and Pusan. Then, the wheels of KTX are going to operate on various rails such as KS50N and KS60 of conventional line as well as UIC60 of high-speed line. Also, conventional line will have a mixed traffic mode with various types of trains operating on it, such as Saemaul and Mugunghwa. Hence, this study reviews the wear phenomena of wheels and rails in geometrical point of view by comparing their profiles. The analyses of the results show that because UIC60 rail is designed for KTX, KS50N rail whose profile is similar to that of UIC60 will not have any impact on the shape of wheel wear. On the other hand, KS60 rail is expected to have partial wear on both the flange of KTX wheel and the gauge corner of the rail in the initial stages. However, the operation of the trains whose wheels have 1/20 conicity will cause partial sidewear on the inside of the rail and the movement of the contact point between KTX wheel and the rail toward the inside of the track. As a result, the flange wear of KTX wheel will be reduced and the formation of wear-equilibrium profile will be faster.

  • PDF

A Study on the Reflow Characteristics of Cu Thin Film (구리 박막의 Reflow 특성에 관한 연구)

  • Kim, Dong-Won;Gwon, In-Ho
    • Korean Journal of Materials Research
    • /
    • v.9 no.2
    • /
    • pp.124-131
    • /
    • 1999
  • Copper film, which is expected to be used as interconnection material for 1 giga DRAM integrated circuits was deposited on hole and trench patterns by Metal Organic Chemical Vapor Deposition(MOCVD) method. After a reflow process, contact and L/S patterns were filled by copper and the characteristics of the Cu reflow process were investigated. When deposited Cu films were reflowed, grain growth and agglomeration of Cu have occurred in surfaces and inner parts of patterns as well as complete filling in patterns. Also Cu thin oxide layers were formed on the surface of Cu films reflowed in $O_2$ambient. Agglomeration and oxidation of Cu had bad influence on the electrical properties of Cu films especially, therefore, their removal and prevention were studied simultaneously. As a pattern size is decreased, preferential reflow takes place inside the patterns and this makes advantages in filling patterns of deep submicron size completely. With Cu reflow process, we could fill the patterns with the size of deep sub-micron and it is expected that Cu reflow process could meet the conditions of excellent interconnection for 1 giga DRAM device when it is combined with Cu MOCVD and CMP process.

  • PDF