• Title/Summary/Keyword: complete blood count(CBC)

Search Result 74, Processing Time 0.027 seconds

Complete Blood Count Reference Intervals and Patterns of Changes Across Pediatric, Adult, and Geriatric Ages in Korea

  • Nah, Eun-Hee;Kim, Suyoung;Cho, Seon;Cho, Han-Ik
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.503-511
    • /
    • 2018
  • Background: Sampling a healthy reference population to generate reference intervals (RIs) for complete blood count (CBC) parameters is not common for pediatric and geriatric ages. We established age- and sex-specific RIs for CBC parameters across pediatric, adult, and geriatric ages using secondary data, evaluating patterns of changes in CBC parameters. Methods: The reference population comprised 804,623 health examinees (66,611 aged 3-17 years; 564,280 aged 18-59 years; 173,732 aged 60-99 years), and, we excluded 22,766 examinees after outlier testing. The CBC parameters (red blood cell [RBC], white blood cell [WBC], and platelet parameters) from 781,857 examinees were studied. We determined statistically significant partitions of age and sex, and calculated RIs according to the CLSI C28-A3 guidelines. Results: RBC parameters increased with age until adulthood and decreased with age in males, but increased before puberty and then decreased with age in females. WBC and platelet counts were the highest in early childhood and decreased with age. Sex differences in each age group were noted: WBC count was higher in males than in females during adulthood, but platelet count was higher in females than in males from puberty onwards (P <0.001). Neutrophil count was the lowest in early childhood and increased with age. Lymphocyte count decreased with age after peaking in early childhood. Eosinophil count was the highest in childhood and higher in males than in females. Monocyte count was higher in males than in females (P <0.001). Conclusions: We provide comprehensive age- and sex-specific RIs for CBC parameters, which show dynamic changes with both age and sex.

An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters

  • Kim, Young-gon;Kwon, Jung Ah;Moon, Yeonsook;Park, Seong Jun;Kim, Sangwook;Lee, Hyun-A;Ko, Sun-Young;Chang, Eun-Ah;Nam, Myung-Hyun;Lim, Chae Seung;Yoon, Soo-Young
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.512-517
    • /
    • 2018
  • Background: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. Methods: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. Results: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. Conclusions: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations.

Assessment of bovine blood sample stability for complete blood count and blood gases and electrolytes analysis during storage

  • Espiritu, Hector M.;Faruk, Shohel Al;Lee, Gyeong-jae;Lopez, Bryan Irvine M.;Lee, Sang-suk;Cho, Yong-il
    • Korean Journal of Veterinary Service
    • /
    • v.42 no.4
    • /
    • pp.265-274
    • /
    • 2019
  • Delayed arrival of blood samples from the field and a large number of samples delivered often causes delay in sample analysis leading to inaccurate measurements. Therefore, this study aimed to assess whether prolonged storage in refrigerator could influence the stability of cattle blood samples and to establish an optimal time limit for complete blood count (CBC) parameters and blood gas and electrolyte (BGE) parameters analyses. Samples collected from healthy cows were tested immediately for CBC and BGE using automated hematology, blood gas and electrolyte analyzers. Samples were kept in refrigerator at 4℃ and analyzed after 6 h, 12 h, 24 h, 48 h, 72 h, 120 h, and 192 h of storage. Mean differences between observations were assessed at 5% significance level using ANOVA and Duncan's multiple range test. Total CBC parameters and the platelet profile remained stable for 192 h, except for MCHC. Among leukocyte-related counts, NEU and EOS remained stable for 192 hours. WBC and LYM, and MONO values produced inconsistent measurements which recovered its initial measurement after 12 h and 24 h of storage, respectively, then remained stable until 120 h. Among the blood gas indices, PCO2, PO2, tCO2, and BE showed declining and significant changes over time, but pH, tHb, and SO2 remained stable for 192 h. Electrolyte status in the blood showed that ions are unstable and tend to change in as early as 6 h of storage. This study established that cattle blood specimens for CBC analysis can be stored for 120 h at 4℃, but specimens for BGE analyses must be tested within 6 to 24 h.

Improving Productive and Reproductive Performance of Holstein Dairy Cows through Dry Period Management

  • Safa, S.;Soleimani, A.;Heravi Moussavi, A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.5
    • /
    • pp.630-637
    • /
    • 2013
  • To determine the effects of dry period (DP) length on milk yield, milk composition, some blood metabolites, complete blood count (CBC), body weight and score and follicular status, twenty five primiparous and multiparous Holstein cows were assigned to a completely randomized design with DP-60 (n = 13) and DP-20 (n = 12) dry period lengths. Cows in the DP-60 produced more milk, protein, SNF, serum non-esterified fatty acids (NEFA) and beta hydroxyl butyrate acid (BHBA) compared with cows in DP-20 ($p{\leq}0.05$). Serum glucose, blood urea nitrogen (BUN), urea, and glutamic oxaloacetic transaminase (GOT) were all similar among the treatments. Body Condition Score (BCS), body weight (BW), complete blood count (CBC) and health problems were similar between the treatments. Diameter of the first dominant follicle and diameter of the dominant follicle on d 14 were different among the treatments. Thus, results of this study showed that reducing the dry period length to DP-20 had a negative effect on milk production, milk composition and reproductive performance in Holstein dairy cows.

A Comparison of Complete Blood Cell Count in Canine Blood Samples Obtained from the Jugular Vein, Cephalic Vein and Lateral Saphenous Vein

  • An, Hyung-Mo;Song, Joong-Hyun;An, Su-Jin;Yu, Do-Hyeon;Kim, Young Joo;Han, Donghyun;Jung, Dong-In
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.314-318
    • /
    • 2019
  • The purpose of this study was to compare the results of complete blood cell count (CBC) of blood samples collected from the jugular vein, cephalic vein and lateral saphenous vein and to find out if there were clinically significant differences. Total of 40 dogs were tested. CBC tests were conducted with blood samples obtained from the jugular vein, cephalic vein and lateral saphenous vein and manual differential count was performed to accurately distinguish the white blood cell (WBC) types. The results were analyzed using Repeated Measures ANOVA and posthoc test was conducted using the least significant difference method. As a result, there was a statistically significant difference (P < 0.05) in the total WBC and monocyte count. The post-hoc test of total WBC counts revealed a significant difference between the jugular vein and cephalic vein, and the jugular vein and lateral saphenous vein. For monocyte counts, a significant difference was observed between the jugular vein and lateral saphenous vein.

The Case-Control Study on Complete Blood Count as a Risk Factor of Stroke (뇌졸중 위험지표로서의 일반혈액검사 소견에 대한 환자;대조군 연구)

  • Lee, Hyon-Ui;Kang, Kyung-Won;Yu, Byeong-Chan;Bang, Ok-Sun;Baek, Kyung-Min;Seol, In-Chan;Kim, Yoon-Sik
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.872-885
    • /
    • 2007
  • Objective : Stroke is one of the most common causes of death in Korea. This study was done to evaluate the association of complete blood count (CBC) with the risk of hemorrhagic stroke and ischemic stroke. Methods : In 217-case patients with ischemic stroke or hemorrhagic stroke and 146 healthy control subjects without stroke, hypertension, diabetes mellitus, hyperlipidemia, or ischemic heart disease and 160 controls without ischemic stroke or hemorrhagic stroke, we tested and compared white blood cell count (WBC), red blood cell count (RBC), hemoglobin (Hgb), hematocrit (Hct) and platelet. These data were statically analyzed by general linear models and binary logistic regression analysis to get each adjusted odds ratio. Results :The level of WBC was significantly higher in all cases. The level of RBC, Hct and Hgb was significantly lower in patients of ischemic stroke. The level of platelet was significantly higher in patients of ischemic stroke. Conclusion : These results suggest high WBC may be a risk factor of hemorrhagic stroke and ischemic stroke and low RBC, low Hct, low Hgb and high platelet may be risk factors of ischemic stroke in Koreans.

  • PDF

Association between gestational age at delivery and lymphocyte-monocyte ratio in the routine second trimester complete blood cell count

  • Cha, Hyun-Hwa;Kim, Jong Mi;Kim, Hyun Mi;Kim, Mi Ju;Chong, Gun Oh;Seong, Won Joon
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.34-38
    • /
    • 2021
  • Background: We aimed to determine whether routine second trimester complete blood cell (CBC) count parameters, including neutrophil-lymphocyte ratio (NLR), lymphocyte-monocyte ratio (LMR), and platelet-lymphocyte ratio (PLR), could predict obstetric outcomes. Methods: We included singleton pregnancies for which the 50-g oral glucose tolerance test and CBC were routinely performed between 24 and 28 weeks of gestation in our outpatient clinic from January 2015 to December 2017. The subjects were divided into three groups according to their pregnancy outcomes as follows: group 1, spontaneous preterm births, including preterm labor and preterm premature rupture of membranes; group 2, indicated preterm birth due to maternal, fetal, or placental causes (hypertensive disorder, fetal growth restriction, or placental abruption); and group 3, term deliveries, regardless of the indication of delivery. We compared the CBC parameters using a bivariate correlation test. Results: The study included 356 pregnancies. Twenty-eight subjects were in group 1, 20 in group 2, and 308 in group 3. There were no significant differences between the three groups in neutrophil, monocyte, lymphocyte, and platelet counts. Although there was no significant difference in NLR, LMR, and PLR between the three groups, LMR showed a negative correlation with gestational age at delivery (r =-0.126, p =0.016). Conclusion: We found that a higher LMR in the second trimester was associated with decreased gestational age at delivery. CBC parameters in the second trimester of pregnancy could be used to predict adverse obstetric outcomes.

Classification of acute clinical mastitis on the base of vital signs and complete blood count test in dairy cows

  • Hur, Tai-Young;Kang, Seog-Jin;Jung, Young-Hun;Lee, Hyun-June;Ki, Kwang-Seok;Choe, Chang-Yong;Suh, Guk-Hyun
    • Korean Journal of Veterinary Research
    • /
    • v.53 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • This study was carried out to evaluate the diagnosis of acute clinical mastitis (ACM) which was based on the vital signs and complete blood count (CBC) tests in dairy cows. Twenty eight dairy cows diagnosed with ACM, were selected for the study between Jan 2003 and July 2006 in the National Institute of Animal Science. Based on their vital signs (rectal temperature, depression, rumen contraction and, dehydration status), ACM was divided into three different classes; mild, moderate and severe forms. In addition, ACM cows were subjected to CBC tests for further diagnosis of ACM. Of the 27 dairy cows diagnosed with ACM, 3 cows were determined to have a mild form, while moderate and sever forms were each observed in twelve cows. Among of them, 4 cows died, 5 cows were culled and 18 cows were recovered. In the mild form, all haematological parameters were comparable with normal values. However, leukopenia, due to neutropenia and lymphocytopenia, appeared characteristically in the moderate and severe forms. Using the observation of vital signs in conjunction with CBC tests, the diagnosis of ACM is more accurate, and is helpful in making decisions of whether treatment or culling of dairy cows infected with ACM is most appropriate.

The Effects of Aerobic Exercise on Body Temperature and Blood Components on Smoking Male University Students (남자 대학생들의 흡연여부에 따른 유산소운동이 체열과 혈액 검사치에 미치는 영향)

  • Lee, Jin;Bang, Hyun-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Background: To determine the effect of Aerobic exercise(AE) on body temperature and blood components in smoking male subjects. Methods: 15 subjects were randomly assigned to Smoking group(smoking, n=8) and Non-smoking group(Non-smoking, n=7). To measure body temperature and blood components. For evaluation of body temperature, the Infrared Thermography, IT was used, and blood components was measured using the Complete Blood cell Count(CBC). Results: The results shows that White blood cell (WBC) was significantly (p<0.05) increased in Smoking group. and no significantly difference between groups(p<0.05). Regarding body temperature, was significantly (p<0.05) increased in Smoking group and Non-somking group. and no significantly difference between groups(p<0.05). Conclusion: Aerobic exercise can increase White blood cell and body temperature in smokers.

Comparison of Scattered Light of ex vivo Mouse Neutrophils by Different Wavelength Laser Irradiation (2개의 레이저 파장에 따른 마우스 호중구의 산란광 비교 연구)

  • Park, Jae-Sung;Son, Min-Ji;Hwang, Chang-Soon;Lee, Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.365-378
    • /
    • 2022
  • Complete blood cell count(CBC) is a technique that counts leukocytes for each type of blood cell being analyzed. The principle is that laser is incident to ex vivo flowing leukocytes in a microcapillary tube and scattered light occurs by laser and leukocytes. By collecting the scattered light, we can count the types of cells because different cells generate different light-scattering patterns. However, the technique has an intrinsic limitation, scattering pattern is shown in a wide range region in the resulting, which makes it difficult to accurate analyze and use fluorescent dyes. To overcome this limitation, a new design of CBC with a dual laser, which irradiates with orthogonal angles for collecting quad-scattering information was proposed. Before development, the scattering difference depending on wavelength must be investigated to only catch up to the scattered signal by angles. Some studies, which focused on simple particles, have been conducted to theoretically and experimentally investigate different scatterings by wavelength. In this study, we propose an optical system for measuring scattered light and investigate a complex particle. As a result, the green laser made strong scattering signals in both the forward and side direction: 10% and 30%, respectively.