Browse > Article
http://dx.doi.org/10.7853/kjvs.2019.42.4.265

Assessment of bovine blood sample stability for complete blood count and blood gases and electrolytes analysis during storage  

Espiritu, Hector M. (Department of Animal Science and Technology, Sunchon National University)
Faruk, Shohel Al (Department of Animal Science and Technology, Sunchon National University)
Lee, Gyeong-jae (Department of Animal Science and Technology, Sunchon National University)
Lopez, Bryan Irvine M. (Department of Animal Science and Technology, Sunchon National University)
Lee, Sang-suk (Department of Animal Science and Technology, Sunchon National University)
Cho, Yong-il (Department of Animal Science and Technology, Sunchon National University)
Publication Information
Korean Journal of Veterinary Service / v.42, no.4, 2019 , pp. 265-274 More about this Journal
Abstract
Delayed arrival of blood samples from the field and a large number of samples delivered often causes delay in sample analysis leading to inaccurate measurements. Therefore, this study aimed to assess whether prolonged storage in refrigerator could influence the stability of cattle blood samples and to establish an optimal time limit for complete blood count (CBC) parameters and blood gas and electrolyte (BGE) parameters analyses. Samples collected from healthy cows were tested immediately for CBC and BGE using automated hematology, blood gas and electrolyte analyzers. Samples were kept in refrigerator at 4℃ and analyzed after 6 h, 12 h, 24 h, 48 h, 72 h, 120 h, and 192 h of storage. Mean differences between observations were assessed at 5% significance level using ANOVA and Duncan's multiple range test. Total CBC parameters and the platelet profile remained stable for 192 h, except for MCHC. Among leukocyte-related counts, NEU and EOS remained stable for 192 hours. WBC and LYM, and MONO values produced inconsistent measurements which recovered its initial measurement after 12 h and 24 h of storage, respectively, then remained stable until 120 h. Among the blood gas indices, PCO2, PO2, tCO2, and BE showed declining and significant changes over time, but pH, tHb, and SO2 remained stable for 192 h. Electrolyte status in the blood showed that ions are unstable and tend to change in as early as 6 h of storage. This study established that cattle blood specimens for CBC analysis can be stored for 120 h at 4℃, but specimens for BGE analyses must be tested within 6 to 24 h.
Keywords
Blood stability; Blood cell count; Blood gas analysis;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Abd Ellah MR, Abd-Elrahman RF, Ahmed HG, Khalaf HT, Mahmoud RR, Sayed SO, Mahmoud RM, Ali RM, Abd-Elmotagaly MF, Abd-Elhadi AN, Abd-Elhamid AM, Mahmoud AK, Abd-Elmegid AS. 2011. Effect of storage time and temperature on erythrocytes, platelets and leucocytes pictures of cattle and equine blood. J. Anim. Vet. Adv. 10, 2768-2771. https://doi.org/10.3923/javaa.2011.2768.2771
2 Constable P, Grunberg W, Staufenbiel R, Stampfli HR. 2013. Clinicopathologic variables associated with hypokalemia in lactating dairy cows with abomasal displacement or volvulus. J. Am. Vet. Med. Assoc. 242, 826-835. https://doi.org/10.2460/javma.242.6.826   DOI
3 Daves M, Zagler EM, Cemin R, Gnech F, Joos A, Platzgummer S, Lippi G. 2015. Sample stability for complete blood cell count using the Sysmex XN haematological analyser. Blood Transfus. 13, 576-582. https://doi.org/10.2450/2015.0007-15
4 Dhondup T, Qian Q. 2017. Acid-Base and Electrolyte Disorders in Patients with and without Chronic Kidney Disease: An Update. Kidney Dis. 3, 136-148. https://doi.org/10.1159/000479968   DOI
5 Freedman JC, Hoffman JF. 1979. Ionic and osmotic equilibria of human red blood cells treated with nystatin. J. Gen. Physiol. 74, 157-185. https://doi.org/10.1085/jgp.74.2.157   DOI
6 Hedberg P, Lehto T. 2009. Aging stability of complete blood count and white blood cell differential parameters analyzed by Abbott CELL-DYN Sapphire hematology analyzer. Int. J. Lab. Hematol. 31, 87-96. https://doi.org/10.1111/j.1751-553X.2007.01009.x   DOI
7 Hussein HA, Aamer AA. 2013. Influence of different storage times and temperatures on blood gas and acid-base balance in ovine venous blood. Open Vet. J. 3, 1-7.   DOI
8 Imeri F, Herklotz R, Risch L, Arbetsleitner C, Zerlauth M, Risch GM, Huber AR. 2008. Stability of hematological analytes depends on the hematology analyser used: A stability study with Bayer Advia 120, Beckman Coulter LH 750 and Sysmex XE 2100. Clin. Chim. Acta 397, 68-71. https://doi.org/10.1016/j.cca.2008.07.018   DOI
9 Jones ML, Allison RW. 2007. Evaluation of the Ruminant Complete Blood Cell Count. Vet. Clin. North Am. - Food Anim. Pract. 23, 377-402. https://doi.org/10.1016/j.cvfa.2007.07.002   DOI
10 Lee S, Kang KP, Kang SK. 2006. Clinical usefulness of the serum anion gap. Electrolyte Blood Press. 4, 44-46. https://doi.org/10.5049/EBP.2006.4.1.44   DOI
11 Margallo SF, Jia B. 2018. Stability of complete rabbit blood count parameters in under various storage times and temperatures. J. Vet. Sci. Technol. 09, 7579. https://doi.org/10.4172/2157-7579-c1-037
12 Tendulkar A, Jain P, Gujral S, Tambe M, Kenjale R, Ganesh B. 2015. Stability of Selected Hematological Parameters in Stored Blood Samples. J. Cell Sci. Ther. 06. https://doi.org/10.4172/2157-7013.1000220
13 Radkowska I, Herbut E. 2014. Hematological and biochemical blood parameters in dairy cows depending on the management system. Anim. Sci. Pap. Reports 32, 317-325.
14 Roland L, Drillich M, Iwersen M. 2014. Hematology as a diagnostic tool in bovine medicine. J. Vet. Diagnostic Investig. 26, 592-598. https://doi.org/10.1177/1040638714546490   DOI
15 Sattar A, Mirza RH. 2009. Haematological parameters in exotic cows during gestation and lactation under subtropical conditions. Pak. Vet. J. 29, 129-132.
16 Wieth JO, Andersen OS, Brahm J, Bjerrum PJ, Borders CL. 1982. Chloride--bicarbonate exchange in red blood cells: physiology of transport and chemical modification of binding sites. Philos. Trans. R. Soc. Lond. B. Biol. Sci. 299, 383-399. https://doi.org/10.1098/rstb.1982.0139   DOI
17 Wu DW, Li YM, Wang F. 2017. How Long can we Store Blood Samples: A Systematic Review and Meta-Analysis. EBioMedicine 24, 277-285. https://doi.org/10.1016/j.ebiom.2017.09.024   DOI
18 Zaninotto M, Tasinato A, Padoan A, Vecchiato G, Pinato A, Sciacovelli L, Plebani M. 2012. Effects of sample transportation on commonly requested laboratory tests. Clin. Chem. Lab. Med. 50, 1755-1760. https://doi.org/10.1515/cclm-2012-0150
19 Aronson PS, Giebisch G. 2011. Effects of pH on Potassium: New Explanations for Old Observations. J. Am. Soc. Nephrol. 22, 1981-1989. https://doi.org/10.1681/asn.2011040414   DOI
20 Anderson BH, Watson DL, Colditz IG. 1999. The effect of dexamethasone on some immunological parameters in cattle. Vet. Res. Commun. 23, 399-413. https://doi.org/10.1023/A:1006365324335   DOI
21 Asirvatham JR, Moses V, Bjornson L. 2013. Errors in potassium measurement: A laboratory perspective for the clinician. N. Am. J. Med. Sci. 5, 255-259. https://doi.org/10.4103/1947-2714.110426   DOI
22 Buttarello M. 2004. Quality specification in haematology: The automated blood cell count. Clin. Chim. Acta 346, 45-54. https://doi.org/10.1016/j.cccn.2004.02.038   DOI
23 Briggs C, Carter J, Lee SH, Sandhaus L, Simon-Lopez R, Vives Corrons JL. 2008. ICSH Guideline for worldwide pointof-care testing in haematology with special reference to the complete blood count. Int. J. Lab. Hematol. 30, 105-116. https://doi.org/10.1111/j.1751-553x.2008.01050.x   DOI
24 Briggs C, Culp N, Davis B, D'Onofrio G, Zini G, Machin SJ. 2014. ICSH guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting, International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.12201
25 Buoro S, Mecca T, Seghezzi M, Manenti B, Cerutti L, Dominoni P, Napolitano G, Resmini S, Crippa A, Ottomano C, Lippi G. 2016. Assessment of blood sample stability for complete blood count using the Sysmex XN-9000 and Mindray BC-6800 analyzers. Rev. Bras. Hematol. Hemoter. 38, 225-239. https://doi.org/10.1016/j.bjhh.2016.05.010
26 Gokce G, Citil M, Gunes V, Atalan G. 2004. Effect of time delay and storage temperature on blood gas and acid-base values of bovine venous blood. Res. Vet. Sci. 76, 121-127. https://doi.org/10.1016/j.rvsc.2003.08.009   DOI
27 Gomez DE, Biermann NM, Sanchez LC. 2015. Physicochemical Approach to Determine the Mechanism for Acid-Base Disorders in 793 Hospitalized Foals. J. Vet. Intern. Med. 29, 1395-1402. https://doi.org/10.1111/jvim.13590   DOI
28 Gunawardena D, Jayaweera S, Madhubhashini G, Lokumarakkala DD, Senanayake SJ. 2017. Reliability of Parameters of Complete Blood Count With Different Storage Conditions. J. Clin. Lab. Anal. 31, 1-6. https://doi.org/10.1002/jcla.22042
29 Medaille C, Briend-Marchal A, Braun JP. 2006. Stability of selected hematology variables in canine blood kept at room temperature in EDTA for 24 and 48 hours. Vet. Clin. Pathol. 35, 18-23. https://doi.org/10.1111/j.1939-165X.2006.tb00083.x   DOI
30 Nnamdi OH, Ijeoma UR, Okaforx NT. 2019. Stability of hematological parameters of canine blood samples stored with citrate phosphate dextrose adenine-1 anticoagulated plastic vacutainers. Vet. World 12, 449-453. https://doi.org/10.14202/vetworld.2019.449-453   DOI