• 제목/요약/키워드: compensate

검색결과 3,992건 처리시간 0.027초

상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘 (A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines)

  • 안용진;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권1호
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

유도전동기의 철손 보상을 위한 간접벡터방식의 구현 (Realization of Indirect Vector Controller to Compensate Ironloss of Induction Motor)

  • 박태식;유지윤;김성환
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권12호
    • /
    • pp.679-685
    • /
    • 1999
  • The purpose of this paper is realizing a rotor-flux-oriented indirect vector controller of an induction motor to compensate the effects of the ironloss generally ignored in the vector controller. Using general ironloss model of induction motor, the vector controller and new decoupling circuit considering ironloss is designed and realized. Also, slip, magnetizing current, stator current and decoupling circuits derived from ironloss model are compared with them from the model not including ironloss and the effects are scrutinized. Finally the total algorithm are realized in 2.2kW servo drive and its effectiveness is verified.

  • PDF

리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘 (A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems)

  • 안용진;강상희;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF

Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer) 개발 (Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method)

  • 정종규;한병문
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1954-1961
    • /
    • 2009
  • This paper describes the development of a three-phase line-interactive dynamic voltage restorer with hybrid detection method, which is composed of three H-bridge inverter modules and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with a 3kVA prototype. The developed system can compensate the input voltage sag and interruption within 2ms. The maximum allowable duration of voltage interruption is about 4 seconds. The developed system can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication devices, and automation devices, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components, and to be highly reliable in operation.

3상 UPS용 인버터의 강인한 비간섭 디지털제어 (Robust Decoupling Digital Control of Three-Phase Inverter for UPS)

  • 박지호;허태원;신동렬;노태균;우정인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.246-255
    • /
    • 2000
  • This paper deals with a novel full digital control method of the three-phase PWM inverter for UPS. The voltage and current of output filter capacitor as state variables are the feedback control input. In addition, a double deadbeat control consisting of a d-q current minor loop and a d-q voltage major loop, both with precise decoupling, have been developed. The switching pulse width modulation based on SVM is adopted so that the capacitor current should be exactly equal to its reference current. In order to compensate the calculation time delay, the predictive control is achieved by the current·voltage observer. The load prediction is used to compensate the load disturbance by disturbance observer with deadbeat response. The experimental results show that the proposed system offers an output voltage with THD less than 2% at a full nonlinear load.

  • PDF

A Seamless Control Method for Supercapacitor to Compensate Pulse Load Transients in DC Microgrid

  • Dam, Duy-Hung;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.198-199
    • /
    • 2017
  • This paper proposed a new control method for supercapacitor (SC) to compensate the pulse load transient and enhance the power quality of dc microgrid. By coordinating the operation frequency, the supercapacitor is controlled to handle the surge current component while the low-frequency current component is dealt with by remaining sources in the system. Based on the state of charge and dc bus voltage level, the SC unit operation mode is automatically decided. Meanwhile, the dc bus voltage level indicates the power demand of the whole system; by regulating the dc bus voltage, the mismatch of power demand is covered by SC unit. The effectiveness of proposed method is verified by experiment prototype formed by two distributed generation and one supercapacitor unit.

  • PDF

3차 볼테라 시스템의 선형화를 위한 적웅 선행처리 기법 (On the Adaptive Pre-processing Technique for the Linearization of a Third-Order Volterra System)

  • 김진영;최봉준;남상원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1289-1291
    • /
    • 1996
  • In this paper, we propose a new adaptive pre-processing technique for the linearization of a weakly nonlinear system which can be modeled by a Volterra series up to third order. To compensate the nonlinear effects of a given system, an update algorithm for the linear filter coefficients of the proposed adaptive pre-processor is introduced, and to compensate the linear distortion of the given system, the linear inverse filter is also utilized. For the performance test of the proposed adaptive pre-processor, computer simulation results obtained by analyzing an ANRSS loudspeaker model are provided.

  • PDF

태양광발전 시스템을 이용한 전력품질 보상시스템 (Power Quality Compensate System Using Photovoltaic System)

  • 한석우;최규하;장도현;신우석;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.76-80
    • /
    • 2001
  • Voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problems in many systems. Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. In this paper, proposed power quality compensate system using photovoltaic system is not only for harmonic compensation but also for harmonic isolation between supply and load, and for voltage regulation and unbalance compensation. Through computer simulations, we have verified the effectiveness of the proposed system.

  • PDF

슬라이딩 모드제어기와 권선형 유도전동기를 이용한 고조파 및 역률보상 (Harmonic and Power Factor Compensation Using WRIM Based on Sliding Mode Controller)

  • 김승모;김윤호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.7-11
    • /
    • 2002
  • This paper proposes an APF(Active Power Filter) with WRIM(Wounded Rotor Induction Motor) controlled by sliding mode which can compensate harmonic currents generated in a power system. As non-linear loads increase gradually in industry fields, harmonic current generated In the electric power network system also increases. Harmonic current makes a power network current distorted and generates heat, vibration and noise In the power machinery, Many approaches have been applied to compensate harmonic currents generated in the power system. Among various control strategy, in this paper, a sliding mode controlled systems is designed and evaluated. This is a flywheel compensator based on secondary excitation of WRIM(wounded rotor induction motor) with SMC(sliding mode controller). The proposed system uses a flywheel as an energy storage device. The designed control scheme is verified through simulation.

  • PDF

포배열카메라 영상을 활용한 함포 사격통제시스템의 동적배열오차 분석 및 보정방법 (Study on Analyzing and Correction of Dynamic Battery Alignment Error in Naval Gun Fire Control System by using Image of Boresight Telescope)

  • 김의진;서태일
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.745-751
    • /
    • 2013
  • In naval gun firing, firing accuracy comes from the combination of each component's accuracy in CFCS (Command and Fire Control System) like tracking sensors and gun. Generally, battery alignment is done to correct the error between gun and tracking sensor by using boresight telescope on harbor and sea. But normally, the battery alignment can compensate only the static alignment error and ignore dynamic alignment error which is caused by own ship movement. There was no research on this dynamic alignment error until now. We propose a new way to analyze dynamic arrangement error by using image of boresight telescope. In case of the dynamic alignment error was due to time delay of own ship attitude information, we propose the way to compensate it.