• Title/Summary/Keyword: comparison patch

Search Result 114, Processing Time 0.034 seconds

Comparison of Characteristics of P-Wave Detection in ECG with Wireless Patch Electrodes

  • Cho, Young Chang;Kim, Min Soo;Yoon, Jeong Oh
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.1
    • /
    • pp.43-52
    • /
    • 2014
  • P-wave characteristic in the human electrocardiogram (ECG) is important in the diagnosis of atrial conduction pathology. In this paper, we measured an ECG signal from patient with cardiovascular disease using one lead ECG electrode system which is based on the wireless cardiac monitoring system. And we detected a P-wave in ECG signal using the complex-valued continuous wavelet transforms (CWT) according to two kinds of patch type electrodes such as an existing narrow patch type electrode and the improved wide patch type electrode presented in this paper. Also, we compared the characteristics in detecting the P-wave in terms of the magnitude and the width of P-waves. From the results of comparison we found that the width and the magnitude of P-wave detected using the wide patch type electrode is improved to be interpreted easier compared to those using the narrow patch type electrode. Furthermore, we have also proven that the complex-valued CWT can be used as a robust detector for P-wave in ECG signal analysis.

Efficacy of Hydrogel Patch in Wound Rat Model (동물모델을 이용한 Hydrogel Patch의 상처치유개선 능력 평가)

  • Oh, Seung-Seok;Kim, Chul-Jun;Kim, Hee-Sook;Shin, Young-Hee
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.55-58
    • /
    • 2009
  • Sodium polyacrylate based hydrogel patch was prepared and its wound healing efficacy in comparison with control groups was evaluated in thermal burn wound ($200^{\circ}C$, 10 sec burn) and excision wound rat model. Cytotoxicity of gamma irradiated (25 kGy) hydrogel patch was investigated in human fibroblasts and showed no significant cytotoxicity. Wound closure rates (H50%) in hydrogel patch group and BAND-$AID^{(R)}$ treated group were faster than that of control group (uncovered open wound). Hydrogel patch showed an enhancement in wound healing process.

Design of "ㄷ"-Shaped Folded Microstrip Patch Antenna ("ㄷ" 자형 폴디드 마이크로스트립 패치 안테나 설계)

  • Heo, Hee-Moo;Seo, Jeong-Sik;Heo, Jin-Young;Woo, Jong-Myung
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.464-467
    • /
    • 2003
  • In this paper, to reduce the patch size of microstrip antenna, folded surface-type patch antenna is designed and fabricated. Size reduction could be achieved because of the downed resonant frequency by the extended current path passing along below the transformated patch surface. Comparison of the patch size at the 1.575 GHz between plane type(length 82 mm${\times}$width 90 mm) and "ㄷ"-shaped folded type is carried and comparision of frequency variation at the same patch size is carried. The result is like that the patch size was reduced than the plane type by 60 mm(73.17 %) at the same frequency. Therefore, it could be checked that "ㄷ"-shaped folded type antenna is advantageous than the plane type in size reduction.

  • PDF

A Study of the Mechanical Properties of Patch-Bonded and Riveted Repairs on Cracked Al 6061-T6 alloy Structures

  • Yoon, Young-Ki;Kim, Guk-Gi;Yoon, Hi-Seak
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.2
    • /
    • pp.55-60
    • /
    • 2000
  • A comparison of Riveted and bonded repairs, bearing and net tension failures, and Al 6061-T6 plates is presented. The results are then compared with previous papers about bonded repairs on different patch materials and shapes. Aluminum alloys, including Al 6061-T6, have a face-centered-cubic crystal structure. Under normal circumstances, these types of crystal structures do not exhibit cleavage fractures even at very low temperatures. In aluminum-base structures, the cracked plate structures are frequently repaired using mechanical fasteners-either rivets of bolts- even though patch-bonding techniques are applied to repair and reinforce the structure. Static test results indicate that the riveted repairs are affected by the position of the rivers. When using the same size of patch, the bonded repair technique is stronger; the rate of elongation is also increased. Form FEM analysis, it is revealed the origin of patch debonding in patch-bonded structures is the edge of the patch along to the tensile strength.

  • PDF

10.525 GHz Band Broadband Inset-fed Microstrip Patch Antenna (10.525 GHz 대역 광대역 인셋-급전 마이크로스트립 패치 안테나)

  • Junho Yeo;Jong-Ig Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.136-141
    • /
    • 2024
  • In this paper, a broadband inset-fed microstrip patch antenna operating at 10.525 GHz band was proposed. The proposed broadband inset-fed microstrip patch antenna consists of three narrow rectangular patches. At the center of the center patch, two symmetrical side patches were connected by a strip conductor and were arranged with their centers shifted in a perpendicular direction with respect to the center patch. For performance comparison, a conventional inset-fed square microstrip patch antenna was designed. Experiment results show that the frequency band of the measured input reflection coefficient with a voltage standing wave ratio less than 2 for the broadband inset-fed microstrip patch antenna was 10.036-11.051 GHz (9.63%), whereas that for the conventional inset-fed rectangular microstrip patch antenna was 10.306-10.772 GHz (4.42%). Therefore, the input reflection coefficient frequency bandwidth of the fabricated broadband inset-fed microstrip patch antenna was increased by 2.18 times, compared to the conventional inset-fed square microstrip patch antenna.

A Preliminary Comparison of the Efficacy of Auricular Acupuncture, Transdermal Nicotine Patch and Combination Therapy for Smoking Cessation (금연 이침과 경피적 니코틴 패치 및 병용 요법 간의 금연 효과에 대한 예비적 비교 연구)

  • Kang, Hee-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.24 no.2
    • /
    • pp.179-188
    • /
    • 2013
  • Objectives : The purpose of this study was to compare three therapies - auricular acupuncture, transdermal nicotine patch and therapy - in combination with auricular acupuncture and nicotine patch. Methods : The subjects of this study included 188 male smokers in their 20s, 30s, 40s and 50s, who visited Wonmi Public Health Center. They were evaluated with the Fagerstrom test for nicotine dependence, amounts of daily smoking and success rate of smoking cessation. The subjects decided on a therapy method strictly of their own choice. They were divided into three groups according to the therapy; auricular acupuncture group (62 persons), nicotine patch group (69 persons) and combination therapy group (57 persons). Results : All three groups resulted in statistically significant reducing effects of nicotine dependence and amounts of daily smoking. In the combination therapy group, nicotine dependence was significantly decreased by more than those of the other groups. There were no statistically significant differences in decrements of daily smoking and success rate of smoking cessation among the three groups. Conclusions : The above results suggest that auricular acupuncture and transdermal nicotine patch have significant effects of smoking cessation. If they are combined, it is expected that therapies for smoking cessation would be developed.

Antidotal and Neuroprotective Efficacies of a Prophylactic Patch against Sarin and Soman Poisonings in Guinea Pigs (신경작용제 사린 및 소만 중독에 대한 기니픽에서의 예방패치의 해독 및 뇌보호 효능)

  • Song, Youngjo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.144-150
    • /
    • 2021
  • This study was designed to evaluate the prophylactic efficacy of a combinational patch system containing physostigmine and procyclidine against sarin and soman using guinea pig. The median lethal dose values of two nerve agents were calculated by a probit analysis of deaths occurring within 24 h. In this study, the values of median lethal dose of sarin and soman were determined to be 33.0 and 26.7 ㎍/kg in guinea-pigs, respectively. The guinea pigs treated with a prophylactic patch(4×5 ㎠) for 24 h were 100 % protected against a challenge of 1.5 LD50. The combinational KMARK-1(atropine and 2-PAM) and prophylactic patch were more effective than a single KMARK-1, a combination of pyridostigmine and KMARK-1 significantly. Epileptiform seizures in the guinea pigs treated with the combinational antidotes led to neuropathological changes, in comparison with intact feature of brain of the animal treated with the patch.

Patch load resistance of longitudinally stiffened webs: Modeling via support vector machines

  • Kurtoglu, Ahmet Emin
    • Steel and Composite Structures
    • /
    • v.29 no.3
    • /
    • pp.309-318
    • /
    • 2018
  • Steel girders are the structural members often used for passing long spans. Mostly being subjected to patch loading, or concentrated loading, steel girders are likely to face sudden deformation or damage e.g., web breathing. Horizontal or vertical stiffeners are employed to overcome this phenomenon. This study aims at assessing the feasibility of a machine learning method, namely the support vector machines (SVM) in predicting the patch loading resistance of longitudinally stiffened webs. A database consisting of 162 test data is utilized to develop SVM models and the model with best performance is selected for further inspection. Existing formulations proposed by other researchers are also investigated for comparison. BS5400 and other existing models (model I, model II and model III) appear to yield underestimated predictions with a large scatter; i.e., mean experimental-to-predicted ratios of 1.517, 1.092, 1.155 and 1.256, respectively; whereas the selected SVM model has high prediction accuracy with significantly less scatter. Robust nature and accurate predictions of SVM confirms its feasibility of potential use in solving complex engineering problems.

Comparison of the Radiation Characteristic of a Microstrip Patch Antenna integrated with a UC-EBG Structure and a Mushroom EBG Structure (UC-EBG 구조와 Mushroom EBG 구조가 집적된 마이크로스트립 패치 안테나의 방사 특성 비교)

  • Kim, Tae-Young;Kim, Boo-Gyoun;Shin, Jong-Dug
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.233-234
    • /
    • 2008
  • Radiation characteristics of a microstrip patch antenna integrated with a UC-EBG (Uniplanar Compact Electromagnetic Bandgap) structure and a Mushroom EBG structure are compared. Radiation characteristics of a patch antenna integrated with a Mushroom EBG structure are better than those of a patch antenna integrated with a UC-EBG structure.

  • PDF

PD Diagnosis on High Voltage Rotating by Using New Prototype Patch Antenna Sensor (prototype 패치 안테나를 이용한 고압 회전기의 부분방전 측정 연구)

  • Lwin, K.S.;Shin, D.H.;Lim, K.J.;Kong, T.S.;Kim, H.D.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.169-171
    • /
    • 2007
  • We studied the partial discharge detecting by sensing electromagnetic wave emitted from the partial discharge source in the HV Rotating Machine with the new prototype patch antenna sensor. In this study, we design new type of patch antenna based on microstrip technology and make many experiments of elaine testing compare with the existing HFCT and EM probe on stator winding of HV generator in the laboratory. This paper will mention comparison of experimental results based on the three kinds of sensors.

  • PDF