• Title/Summary/Keyword: comparison of energy consumption

Search Result 446, Processing Time 0.026 seconds

A Comparative Analysis on Page Caching Strategies Affecting Energy Consumption in the NAND Flash Translation Layer (NAND 플래시 변환 계층에서 전력 소모에 영향을 미치는 페이지 캐싱 전략의 비교·분석)

  • Lee, Hyung-Bong;Chung, Tae-Yun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.3
    • /
    • pp.109-116
    • /
    • 2018
  • SSDs that are not allowed in-place update within the allocated page cause another allocation of a new page that will replace the previous page at the moment data modification occurs. This intrinsic characteristic of SSDs requires many changes to the existing HDD-based IO theory. In this paper, we conduct a performance comparison of FTL caching strategy in perspective of cache hashing (Global vs. grouped) and caching algorithm (LRU vs. NUR) through a simulation. Experimental results show that in terms of energy consumption for flash operation the grouped management of cache is not suitable and NUR algorithm is superior to LRU algorithm. In particular, we found that the cache hit ratio of LRU algorithm is about 10% point higher than that of NUR algorithm while the energy consumption of LRU algorithm is about 32% high.

The Energy Performance & Economy Efficiency Evaluation of Microturbine Installed in Hospital buildings (대형병원에서 마이크로터빈 이용한 열병합시스템 에너지성능 및 경제성 분석)

  • Kim, Byung-Soo;Gil, Young-Wok;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.176-183
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat, and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30[%] after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40[%]. If electricity energy and waste heat in turbine are used, 56[%] of heating energy and 67[%] of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70[%].

Ondol Heating System Using Heat Pump - Comparison of Energy Consumption between the Heat Pump and the Oil Boiler - (열펌프를 이용한 온돌 난방 시스템 - 열펌프와 석유보일러의 소요에너지 비교 -)

  • 김현철;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.351-358
    • /
    • 1999
  • In these days, we are faced to a couple of difficult problems, the one is the unstable price of the energy due to the shortage of fossil fuel resources and the other is the serious environmental pollution from the excessive consumption of fossil fuel. In order to save the thermal energy for the house heating, in this study the heat pump using the natural thermal energy resources was provided for Ondol heating and the thermal energy consumption of the heat was compared to that of oil boiler. The results could be summarized as follows: 1. In the Ondol room the temperature difference between the Ondol surface and room air was about 5∼$10^{\circ}C$ in accordance with the ambient temperature. 2. The Ondol room heating efficiency of the heat pump with compressor of 2PS was the highest at the water flow rate of 200 l/h. 3. The energy saving rate of the heat pump to the oil boiler for heating the Ondol system was 19.3%. 4. The Ondol heating cost of the heat pump was less 20.6% than that of oil boiler when oil price was 478 won/l.

  • PDF

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

Heating and Hot Water Supply Energy Comparison of Medium Capacity and Multi Boilers System applied to Military Officer Housing (군간부 숙소에 적용된 중용량 및 멀티 보일러 시스템의 난방 및 급탕에너지 비교)

  • Kim, Min-Yong;Kim, Young Il;Chung, Kwang Seop
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.3
    • /
    • pp.8-16
    • /
    • 2014
  • Heating and hot water supply energy consumption of medium and multi boiler systems applied to military officer housing are compared with in-situ experiment and TRNSYS dynamic simulation program. In a multiple boiler system, small capacity boilers are connected in parallel to meet the required capacity. For handling partial loads, medium capacity boiler relies on on-off control, while multi boiler adopts PI control. Since multi boiler has higher efficiency and better control strategy, the results show that energy consumption can be reduced significantly with the multi boiler system.

The power consumption and performance comparison between Intel Pentium 4 and Core2 Duo (인텔 펜티엄 4와 코어2 듀오의 실행시간과 파워소모량 효율성 비교)

  • Kong, Joon-Ho;Choi, Jin-Hang;Lee, Jong-Sung;Chung, Sung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.7
    • /
    • pp.165-172
    • /
    • 2008
  • There are many metrics when designing microprocessors. Especially, energy, power consumption and performance are the most fundamental metrics. Since these metrics are contradictory, microprocessor designers give more weight to some metrics than the other metrics. In this paper, we compare Intel Pentium 4 and Core2 Duo both qualitatively and quantitatively. Furthermore, we provide detailed comparison between Pentium 4 and Core2 Duo when running real benchmarks. Through performance counter of real processors, we calculate energy and power consumption. Performance metric is execution time. In experimental result, Core2 Duo consumes less energy and power. Moreover, performance of Core2 Duo is also better than that of Pentium 4. However, in case of bzip2 which is optimized in Pentium 4, Pentium 4 shows much better performance and lower energy and power consumption than Core2 Duo.

  • PDF

Experimental Study on Optimal Operation Strategies for Energy Saving in Building Central Cooling System (건물 중앙냉방시스템의 에너지절감을 위한 최적운전 방안에 관한 실험적 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4610-4615
    • /
    • 2013
  • In this study, optimal operation strategies to save the electric energy and power price in the building central cooling system is researched by experiments. The optimal strategies of demand response control and outdoor temperature reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested optimal control method shows better responses in the power price and energy consumption in comparison with the conventional one and saves energy consumption by 9.5% and electronic price by 15.7%, respectively.

Effect of Arm Sling on Walk Speed and Energy Consumption in Patients with Stroke (팔걸이가 뇌졸중 환자의 보행속도 및 에너지 소모량에 미치는 영향)

  • Yoon, Seoung-Ic;Kim, Yoon-Shin;Shim, Jae-Hun;Oh, Kyung-Ah;Oh, Duck-Won;Chon, Seung-Chul
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.39-45
    • /
    • 2008
  • This study was undertaken to identify the influence which affect on gait speed and energy consumption regarding putting on arm sling during gait of the 40 hemiplegic patients selected from University Hospital and rehabilitation center in seoul during two months. The analysis of data was performed using the paired samples ttest to compare the differences of gait velocity, heart rate, oxygen consumption and oxygen cost in gait of preand post- arm sling. The results of this study were as follows; 1. When comparing the result before putting on arm sling in the gait of hemiplegic patient, gait velocity after putting on arm sling was statistically significantly increased(p<.05). 2. When comparing the result before putting on arm sling in the gait of hemiplegic patient, heart rate after putting on arm sling was statistically significantly decreased(p<.05). 3. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption per weight after putting on arm sling was statistically significantly decreased(p<.05). 4. When comparing the result before putting on arm sling in the gait of hemiplegic patient, oxygen consumption rate per weight after putting on arm sling was statistically significantly decreased(p<.05). When putting together the above result, the gait with arm sling in comparison with the gait without arm sling was to increase gait velocity, decrease heart rate, decrease oxygen consumption and was finally to decrease energy consumption in the gait of hemiplegic patient.

  • PDF

Performance Evaluation of Energy Reduction of Light Shelf Applying Punching Plate

  • Choi, Yuchang;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.5-13
    • /
    • 2014
  • Various studies on lighting energy savings are conducted, given that lighting energy consumption accounts 23.5% of building energy consumption. Especially, external type light shelf's efficiency is acknowledged; however, its application is limited in Korea, where high rise building ratio is high, due to high wind pressure. This study delves into natural lighting system to cope with wind pressure, and proposes the punching plate-installed light shelf. This study actually draws lighting energy output, according to whether the punching plate is applied through the test-bed, and verifies the effectiveness of the punching plate-installed light shelf. The conclusion is presented below: First) The result of performance evaluation of light shelf with the punching plate in winter solstice showed that the awning area decreased as the opening ratio increased so that the indoor distributed illumination tended to increase, and $-40^{\circ}$ which was advantageous for awning was determined as the proper angle. Second) The light shelf with the punching plate in spring/autumn equinox shows improved lighting according to the angle, and the appropriate angle of light shelf with the punching plate has increased to $15^{\circ}$ and $20^{\circ}$ according to the opening ratio in comparison to $5^{\circ}C$ which is the appropriate angle of light shelf with no punching plate due to the reflection area reduced by the reflecting plate with holes. Third) The result of performance evaluation of light shelf with the punching plate in summer solstice showed that the lighting performance tended to decrease as the opening ratio increased. 4) The light shelf with the punching plate incurs a 50% energy loss in comparison to the light shelf with no punching plate. However, its effectiveness has been proven in the aspects that it can bring a 50% energy saving in comparison to the case with no installation of light shelf and that it can be designed in response to wind pressure on the high floors.

An Analysis of the Prediction Accuracy of HVAC Fan Energy Consumption According to Artificial Neural Network Variables (인공신경망 변수에 따른 HVAC 에너지 소비량 예측 정확도 평가 - 송풍기를 중심으로-)

  • Kim, Jee-Heon;Seong, Nam-Chul;Choi, Won-Chang;Choi, Ki-Bong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.73-79
    • /
    • 2018
  • In this study, for the prediction of energy consumption in the ventilator, one of the components of the air conditioning system, the predicted results were analyzed and accurate by the change in the number of neurons and inputs. The input variables of the prediction model for the energy volume of the fan were the supply air flow rate, the exhaust air flow rate, and the output value was the energy consumption of the fan. A predictive model has been developed to study with the Levenbarg-Marquardt algorithm through 8760 sets of one-minute resolution. Comparison of actual energy use and forecast results showed a margin of error of less than 1% in all cases and utilization time of less than 3% with very high predictability. MBE was distributed with a learning period of 1.7% to 2.95% and a service period of 2.26% to 4.48% respectively, and the distribution rate of ${\pm}10%$ indicated by ASHRAE Guidelines 14 was high.8.