• Title/Summary/Keyword: comparison accuracy

Search Result 3,244, Processing Time 0.029 seconds

Performance Comparison of Scaffold Defect Detection Model by Parameters (파라미터에 따른 인공지지체 불량 탐지 모델의 성능 비교)

  • Song Yeon Lee;Yong Jeong Huh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.54-58
    • /
    • 2023
  • In this study, we compared the detection accuracy of the parameters of the scaffold failure detection model. A detection algorithm based on convolutional neural network was used to construct a failure detection model for scaffold. The parameter properties of the model were changed and the results were quantitatively verified. The detection accuracy of the model for each parameter was compared and the parameter with the highest accuracy was identified. We found that the activation function has a significant impact on the detection accuracy, which is 98% for softmax.

  • PDF

A Comparison of the Discrimination of Business Failure Prediction Models (부실기업예측모형의 판별력 비교)

  • 최태성;김형기;김성호
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.27 no.2
    • /
    • pp.1-13
    • /
    • 2002
  • In this paper, we compares the business failure prediction accuracy among Linear Programming Discriminant Analysis(LPDA) model, Multivariate Discriminant Analysis (MDA) model and logit analysis model. The Data for 417 companies analyzed were gathered from KIS-FAS Published by Korea Information Service in 1999. The result of comparison for four time horizons shows that LPDA Is advantageous in prediction accuracy over the other two models when over all tilt ratio and business failure accuracy are considered simultaneously.

CCD PHOTOMETRY USING MULTIPLE COMPARISON STARS

  • Kim, Yong-gi;Andronov, Ivan L.;Jeon, Young-Beom
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.3
    • /
    • pp.191-200
    • /
    • 2004
  • The accuracy of CCD observations obtained at the Korean 1.8m telescope has been studied. Seventeen comparison stars in the vicinity of the cataclysmic variable BG CMi have been measured. The 'artificial' star has been used instead of the 'control' star, what made possible to increase accuracy estimates by a factor of 1.3-2.1 times for 'good' and 'cloudy' nights, respectively. The algorithm of iterative determination of accuracy and weights of few comparison stars contributing to the artificial star, has been presented. The accuracy estimates for 13-mag stars are around $0.^m002$ mag for exposure times of 30 sec.

Evaluation of KOMPSAT-1 Orbit Determination Accuracy

  • Kim, Hae-Dong;Choi, Hae-Jin;Kim, Eun-kyou
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.588-590
    • /
    • 2003
  • For the normal operations, KOMPSAT-1 orbits are determined using GPS navigation solutions data such as position and velocity vectors. Currently, the accuracy of GPS navigation solution data is generally known as on the order of 10~30 m with the removal of S/A. In this paper, an estimate of the current orbit determination accuracy for the KOMPSAT-1 is given. For the evaluation of orbit determination accuracy, the orbit overlap comparison is used since no independent orbits of comparable accuracy are available for comparison. As a result, It is shown that the orbit accuracy is on the order of 5 m RMS with 4 hrs arc overlap for the 30 hr arc.

  • PDF

Analysis of Direction Finding Accuracy for Amplitude-Phase Comparison and Correlative Interferometer Method (진폭-위상 복합비교 기법과 상관형 위상비교 기법의 방향탐지 정확도 분석)

  • Lim, Joong-Soo;Chae, Gyoo-Soo
    • Journal of Digital Convergence
    • /
    • v.14 no.1
    • /
    • pp.195-201
    • /
    • 2016
  • In this paper, we present the direction finding accuracy of correlative interferometer method and amplitude-phase comparison method. Spiral antennas are used for amplitude-phase comparison method and blade antennas are used for correlative interferometer method. Those are made for uniform circular array (UCA) direction finding antenna systems. We simulate the accuracy of azimuth angle with 3 antennas UCA when SNR is 20 dB and baseline is 0.5 wave length. Correlative interferometer method has better accuracy than amplitude-phase comparison method.

Comparison of Step Counting Methods according to the Internal Material Molding Methods for the Module of a Smart Shoe

  • Jang, Si-Woong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.1
    • /
    • pp.90-99
    • /
    • 2021
  • Recently, studies on wearable devices in ubiquitous computing environments have increased and the technology collecting user's activities to provide services has received great attention. We have compared the step counting methods according to sensor molding methods in case of counting steps by using the piezoelectric sensor. We have classified the cases which could result from the course of molding the internal module of a smart shoe as follows: (i) the module is unmolded, (ii) molded but only to the extent that a sensor is fixed or (iii) molded to the extent that a sensor is not moved. Moreover, we have made comparison to verify which algorithm should be used to increase the accuracy of counting steps by the respective cases. Based on the comparison result, we have confirmed that the accuracy of counting steps is higher when using gradient value rather than when using threshold value. In the case of no molding and small molding under the condition of using gradient value, it was turned out to be 100% accuracy for step counting.

The Development of Exercise Accuracy Measurement Algorithm Supporting Personal Training's Exercise Amount Improvement

  • Oh, Seung-Taek;Kim, Hyeong-Seok;Lim, Jae-Hyun
    • International journal of advanced smart convergence
    • /
    • v.11 no.4
    • /
    • pp.57-67
    • /
    • 2022
  • The demand for personal training (PT), through which high exercise effects can be achieved within short-term, has recently increased. PT can achieve an exercise amount improvement effect, only if accurate postures are maintained upon performing PT, and exercise with inaccurate postures can cause injuries. However, research is insufficient on exercise amount comparisons and judging exercise accuracy on PT. This study proposes an exercise accuracy measurement algorithm and compares differences in exercise amounts according to exercise postures through experiments using a respiratory gas analyzer. The exercise accuracy measurement algorithm acquires Euler anglesfrom major body parts operated upon exercise through a motion device, based on which the joint angles are calculated. By comparing the calculated joint angles with each reference angle in each exercise step, the status of exercise accuracy is judged. The calculated results of exercise accuracy on squats, lunges, and push-ups showed 0.02% difference in comparison with actually measured results through a goniometer. As a result of the exercise amount comparison experiment according to accurate posture through a respiratory gas analyzer, the exercise amount was higher by 45.19% on average in accurate postures. Through this, it was confirmed that maintaining accurate postures contributes to exercise amount improvement.

A Comparative Study of Wetland Change Detection Techniques Using Post-Classification Comparison and Image Differencing on Landsat-5 TM Data (랜�V-5호(號) TM 데이타를 이용(利用)한 구분후(區分后) 비교(比較) 및 영상대차(映像對差)의 습지대(濕地帶) 변화(變化) 탐지(探知) 기법(技法)에 관(關)한 비교연구(比較硏究))

  • Choung, Song Hak;Ulliman, Joseph J.
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.4
    • /
    • pp.346-356
    • /
    • 1992
  • The extensive Snake River floodplain in Northwest United States has experienced major changes in water channels and vegetation types due to floodings. To detect the change of wetland cover-types for the period of 1985 and 1988, post-classification comparison and image differencing change detection techniques were evaluated using Landsat-5 TM digital data. Differenced infrared-band images indicated better accuracy indices than any visible-band images. A thresholding technique was applied to identify the change and no change categories from the transformed images produced by image differencing. The problems in using different accuracy indices, including the Kappa coefficient of agreement, overall accuracy, producer's accuracy, user's accuracy, and average accuracy(based on both the producer's and user's accuracy approaches) in determining an optimal threshold level, were examined.

  • PDF

Comparison the Mapping Accuracy of Construction Sites Using UAVs with Low-Cost Cameras

  • Jeong, Hohyun;Ahn, Hoyong;Shin, Dongyoon;Choi, Chuluong
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.1
    • /
    • pp.1-13
    • /
    • 2019
  • The advent of a fourth industrial revolution, built on advances in digital technology, has coincided with studies using various unmanned aerial vehicles (UAVs) being performed worldwide. However, the accuracy of different sensors and their suitability for particular research studies are factors that need to be carefully evaluated. In this study, we evaluated UAV photogrammetry using smart technology. To assess the performance of digital photogrammetry, the accuracy of common procedures for generating orthomosaic images and digital surface models (DSMs) using terrestrial laser scanning (TLS) techniques was measured. Two different type of non-surveying camera(Smartphone camera, fisheye camera) were attached to UAV platform. For fisheye camera, lens distortion was corrected by considering characteristics of lens. Accuracy of orthoimage and DSM generated were comparatively analyzed using aerial and TLS data. Accuracy comparison analysis proceeded as follows. First, we used Ortho mosaic image to compare the check point with a certain area. In addition, vertical errors of camera DSM were compared and analyzed based on TLS. In this study, we propose and evaluate the feasibility of UAV photogrammetry which can acquire 3 - D spatial information at low cost in a construction site.

A Study on the Attributes Classification of Agricultural Land Based on Deep Learning Comparison of Accuracy between TIF Image and ECW Image (딥러닝 기반 농경지 속성분류를 위한 TIF 이미지와 ECW 이미지 간 정확도 비교 연구)

  • Kim, Ji Young;Wee, Seong Seung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.6
    • /
    • pp.15-22
    • /
    • 2023
  • In this study, We conduct a comparative study of deep learning-based classification of agricultural field attributes using Tagged Image File (TIF) and Enhanced Compression Wavelet (ECW) images. The goal is to interpret and classify the attributes of agricultural fields by analyzing the differences between these two image formats. "FarmMap," initiated by the Ministry of Agriculture, Food and Rural Affairs in 2014, serves as the first digital map of agricultural land in South Korea. It comprises attributes such as paddy, field, orchard, agricultural facility and ginseng cultivation areas. For the purpose of comparing deep learning-based agricultural attribute classification, we consider the location and class information of objects, as well as the attribute information of FarmMap. We utilize the ResNet-50 instance segmentation model, which is suitable for this task, to conduct simulated experiments. The comparison of agricultural attribute classification between the two images is measured in terms of accuracy. The experimental results indicate that the accuracy of TIF images is 90.44%, while that of ECW images is 91.72%. The ECW image model demonstrates approximately 1.28% higher accuracy. However, statistical validation, specifically Wilcoxon rank-sum tests, did not reveal a significant difference in accuracy between the two images.