• Title/Summary/Keyword: comparison

Search Result 53,779, Processing Time 0.088 seconds

Possibility of Establishing an International Court of Air and Space Law (국제항공우주재판소의 설립 가능성)

  • Kim, Doo-Hwan
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.24 no.2
    • /
    • pp.139-161
    • /
    • 2009
  • The idea of establishing an International Court of Air and Space Law (hereinafter referred to ICASL) is only my academic and practical opinion as first proposal in the global community. The establishment of the International Court of Air and Space Law can promote the speed and promote fairness of the trial in air and space law cases. The creation of an ICASL would lead to strengthening of the international cooperation deemed essential by the global community towards joint settlement in the transnational air and space cases, claims and would act as a catalyst for the efforts and solution on aircraft, satellite and space shuttle's accidents and cases and all manpower, information, trial and lawsuit to be centrally managed in an independent fashion to the benefit of global community. The aircraft, satellite and spacecraft's accidents attributes to the particular and different features between the road, railway and maritime's accidents. These aircraft, satellite and spacecraft's accidents have incurred many disputes between the victims and the air and space carriers in deciding on the limited or unlimited liability for compensation and the appraisal of damages caused by the aircraft's accidents, terror attack, satellite, space shuttle's accidents and space debris. This International Court of Air and Space Law could hear any claim growing out of both international air and space crash accidents and transnational accidents in which plaintiffs and defendants are from different nations. This alternative would eliminate the lack of uniformity of decisions under the air and space conventions, protocols and agreements. In addition, national courts would no longer have to apply their own choice of law analysis in choosing the applicable liability limits or un-limit for cases that do not fall under the air and space system. Thus, creation of an International Court of Air and Space Law would eliminate any disparity of damage awards among similarly situated passengers and shippers in nonmembers of air and space conventions, protocols, agreements and cases. Furthermore, I would like to explain the main items of the abovementioned Draft for the Convention or Statute of the International Court of Air and Space Law framed in comparison with the Statute of the International Court of Justice, the Statue of the International Tribunal for the Law of the Sea and the Statute of the International Criminal Court. First of all, in order to create the International Court of Air and Space Law, it is necessary for us to legislate a Draft for the Convention on the Establishment of the International Court of Air and Space Law. This Draft for the Convention must include the elected method of judges, term, duty and competence of judge, chambers, jurisdiction, hearing and judgment of the ICASL. The members of the Court shall be elected by the General Assembly and Council of the ICAO and by the General Assembly and Legal Committee of the UNCOPUOS from a list of persons nominated by the national groups in the six continent (the North American, South American, African, Oceania and Asian Continent) and two international organization such as ICAO and UNCOPUOS. The members of the Court shall be elected for nine years and may be re-elected as one time. However, I would like to propose a creation an International Court of Air and Space Law in extending jurisdiction to the International Court of Justice at the Hague to in order to decide the air and space convention‘s cases. My personal opinion is that if an International Court on Air and Space Law will be created in future, it will be settled quickly and reasonably the difficulty and complicated disputes, cases or lawsuit between the wrongdoer and victims and the injured person caused by aircraft, satellite, spacecraft's accidents or hijacker and terrorists etc. on account of deciding the standard of judgment by judges of that’s court. It is indeed a great necessary and desirable for us to make a new Draft for the Convention on a creation of the International Court of Air and Space Law to handle international air and space crash litigation. I shall propose to make a new brief Draft for the Convention on the Creation of an International Court of Air and Space Law in the near future.

  • PDF

Comparison of Electrocardiographic Time Intervals, Amplitudes and Vectors in 7 Different Athletic Groups (운동종목별(運動種目別) 선수(選手)의 심전도시간간격(心電圖時間間隔), 파고(波高) 및 벡터의 비교(比較))

  • Kwon, Ki-Young;Lee, Won-Jung;Hwang, Soo-Kwan;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.19 no.1
    • /
    • pp.61-72
    • /
    • 1985
  • In order to compare the cardiac function of various groups of athletes, the resting electrocardiographic time intervals, amplitudes and vectors were analyzed in high school athletes of throwing(n=7), jumping(n=11), short track(n=8), long track(n=14), boxing(n=7), volleyball(n=8) and baseball(n=9), and nonathletic control students(n= 19). All athletic groups showed a significantly longer R-R interval(0.96-1.09 sec) than the controls (0.78 sec). Therefore, the heart rate was significantly slower in atheletes than in the control, but was not different among the different athletic groups. R-R interval is the sum of intervals of P-R, 0-T and T-P: P-R and Q-T intervals showed no difference among the control and athletic groups, but T-P interval in the jump, short track, long track and boxing groups was significantly higher than the control. R-B interval showed a significant correlation with T-P or Q-T intervals but no correlation with P-R or QRS complex. Comparing the amplitude of electrocardiographic waves, the athletic groups showed a lower trend in P wave than the controls. T wave in lead $V_5\;(Tv_5)$ was similar in the athletic and control groups. The long track group showed a significantly higher waves of $Rv_5$, $Sv_1$, and the sum of $Rv_5$ and $Sv_1$ than not only the controls but also the other athletic group. The angles of P, QRS, and T vector in the frontal and horizontal planes were not different among the control and all the athletic groups. Each athletic group stowed a lower trend in amplitude of P vector in the frontal plane, but in horizontal plane, throwing, jump, short track and baseball groups showed a significantly lower than the controls. The amplitude of QRS and T vector was similar in the athletic and control groups, but only the baseball group showed a significantly higher QRS vector in the frontal plane. In taken together, all the athletic groups showed a slower heart rate than the controls, mainly because of elongated T-P interval. Comparing the electrocardiographic waves and vector, the athletic groups showed lower amplitudes of P wave and P vector than the controls. Values of $Rv_5$ and $Sv_1$ strongly suggest that only the long distance runners among the various athletic groups developed a left ventricular hypertrophy.

  • PDF

Usefulness of LIFE in diagnosis of bronchogenic carcinoma (기관지 암의 진단에서 형광기관지 내시경검사의 유용성)

  • Lee, Sang Hwa;Shim, Jae Jeong;Lee, So Ra;Lee, Sang Youb;Suh, Jung Kyung;Cho, Jae Yun;Kim, Han Gyum;In, Kwang Ho;Choi, Young Ho;Kim, Hark Jei;Yoo, Se Hwa;Kang, Kyung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.69-84
    • /
    • 1997
  • Background : Although the overall prognosis of patients with lung cancer is poor, highly effective treatment exists for the small subset of patients with early lung cancer(carcinoma in situ/micro- invasive cancer). But very few patients have benefit from them because these lesions are difficult to detect and localize with conventional white-light bronchoscopy. To overcome this problem, a Lung Imaging Fluorescence Endoscopic device(LIFE) was developed to detect and clearly delineate the exact location and extent of premalignant and early lung cancer lesions using differences in tissue autofluorescence. Purpose : The purpose of this study was to determine the difference of sensitivity and specificity in detecting dysplasia and carcinoma between fluorescence imaging and conventional white light bronchoscopy. Material and Methods : 35 patients (16 with abnormal chest X-ray, 2 with positive sputum study, 2 with undiagnosed pleural effusion, 15 with respiratory symptom) have been examined by LIFE imaging system. After a white light bronchoscopy, the patients were submitted to fluorescence bronchoscopy and the findings of both examinations have been classified in 3 categories(class I, II, III). From of all class n and III sites, 79 biopsy specimens have been collected for histologic examination: a comparison between histologic results and white light or fluorescence bronchoscopy has been performed for assessing sensitivity and specificity of the two methods. Results : 1) Total 79 sires in 35 patients were examined. Histology demonstrated 8 normal mucosa, 21 hyperplasia, 23 dysplasia, and 27 microinvasive and invasive carcinoma. 2) The sensitivity of white light or fluorescence bronchoscopy in detecting dysplasia was 60.9% and 82.6%, respectively. 3) The results of this study showed 70.3 % sensitivity for microinvasive or invasive carcinoma with LIFE system, versus 100% sensitivity for white light in 27 cases of carcinoma. The false negative study of LIFE system was 8 cases(3 adenocarcinoma and 5 small cell carcinoma), which were infiltrated in submucosal area and had normal epithelium. Conclusion : To improve the ability 10 diagnose and stage more accurately, fluorescence imaging may become an important adjunct to conventional bronchoscopic examination because of its high detection rate of premalignant and malignant epithelial lesion. But. it has limitation to detect in submucosal infiltrating carcinoma.

  • PDF

Comparison of Treatment Planning System(TPS) and actual Measurement on the surface under the electron beam therapy with bolus (전자선 치료 시 Bolus를 적용한 경우 표면선량의 Treatment Planning System(TPS) 계산 값과 실제 측정값의 비교)

  • Kim, Byeong Soo;Park, Ju Young;Park, Byoung Suk;Song, Yong Min;Park, Byung Soo;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.163-170
    • /
    • 2014
  • Purpose : If electron, chosen for superficial oncotherapy, was applied with bolus, it could work as an important factor to a therapy result by showing a drastic change in surface dose. Hence the calculation value and the actual measurement value of surface dose of Treatment Planning System (TPS) according to four variables influencing surface dose when using bolus on an electron therapy were compared and analyzed in this paper. Materials and Methods : Four variables which frequently occur during the actual therapies (A: bolus thickness - 3, 5, 10 mm, B: field size - $6{\time}6$, $10{\time}10$, $15{\time}15cm2$, C: energy - 6, 9, 12 MeV, D: gantry angle - $0^{\circ}$, $15^{\circ}$) were set to compare the actual measurement value with TPS(Pinnacle 9.2, philips, USA). A computed tomography (lightspeed ultra 16, General Electric, USA) was performed using 16 cm-thick solid water phantom without bolus and total 54 beams where A, B, C, and D were combined after creating 3, 5 and 10 mm bolus on TPS were planned for a therapy. At this moment SSD 100 cm, 300 MU was investigated and measured twice repeatedly by placing it on iso-center by using EBT3 film(International Specialty Products, NJ, USA) to compare and analyze the actual measurement value and TPS. Measured film was analyzed with each average value and standard deviation value using digital flat bed scanner (Expression 10000XL, EPSON, USA) and dose density analyzing system (Complete Version 6.1, RIT, USA). Results : For the values according to the thickness of bolus, the actual measured values for 3, 5 and 10 mm were 101.41%, 99.58% and 101.28% higher respectively than the calculation values of TPS and the standard deviations were 0.0219, 0.0115 and 0.0190 respectively. The actual values according to the field size were $6{\time}6$, $10{\time}10$ and $15{\time}15cm2$ which were 99.63%, 101.40% and 101.24% higher respectively than the calculation values and the standard deviations were 0.0138, 0.0176 and 0.0220. The values according to energy were 6, 9, and 12 MeV which were 99.72%, 100.60% and 101.96% higher respectively and the standard deviations were 0.0200, 0.0160 and 0.0164. The actual measurement value according to beam angle were measured 100.45% and 101.07% higher at $0^{\circ}$ and $15^{\circ}$ respectively and standard deviations were 0.0199 and 0.0190 so they were measured 0.62% higher at $15^{\circ}$ than $0^{\circ}$. Conclusion : As a result of analyzing the calculation value of TPS and measurement value according to the used variables in this paper, the values calculated with TPS on 5 mm bolus, $6{\time}6cm2$ field size and low-energy electron at $0^{\circ}$ gantry angle were closer to the measured values, however, it showed a modest difference within the error bound of maximum 2%. If it was beyond the bounds of variables selected in this paper using electron and bolus simultaneously, the actual measurement value could differ from TPS according to each variable, therefore QA for the accurate surface dose would have to be performed.

Effect of Cooling Timing in the Root Zone on Substrate Temperature and Physiological Response of Sweet Pepper in Summer Cultivation (여름 파프리카 수경재배에서 근권 냉방 시간이 근권 온도와 생리적 반응에 미치는 영향)

  • Choi, Ki Young;Ko, Ji Yeon;Yoo, Hyung Joo;Choi, Eun Young;Rhee, Han Cheol;Lee, Yong-Beom
    • Horticultural Science & Technology
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 2014
  • This study aimed to determine an appropriate cooling timing in the root zone for lowering substrate temperature and its effect on physiological response of sweet pepper (Capsicum annum L. 'Orange glory') grown on coir substrate in summer, from the July 16 to October 15, 2012. Daily temperature of substrate, root activity, leaf water potential, first flowering date, and the number of fruits were measured by circulating cool water through a XL pipe in the root zone during either all day (all-day) or only night time (5 p.m. to 3 a.m.; night) from the July 23 to September 23, 2012. For comparison, no cooling (control) was also applied. Between the $23^{rd}$ of July and $31^{st}$ of August (hot temperature period), daily average temperatures in substrates were $25.6^{\circ}C$, $26.1^{\circ}C$, and $29.1^{\circ}C$ for the all-day and night treatment, and control respectively. About 1.8 to $5^{\circ}C$ lower substrate temperature was observed in both treatments compared to that of control. In sunny day ($600-700 W{\cdot}m^{-2}{\cdot}s^{-1}$), the highest temperature of substrate was measured between 4 p.m. and 5 p.m. under both the all-day and night treatments, whereas it was measured between 7 p.m. and 8 p.m. under the control. Substrate temperatures during the day (6 a.m. to 8 p.m.) and night (8 p.m. to 6 a.m.) differed depending on the treatments. During the day and night, averaged substrate temperature was lower about $3.3^{\circ}C$ and $4.0^{\circ}C$ for the all-day, and $2.1^{\circ}C$ and $3.4^{\circ}C$ for the night treatment, compared to that of control. In the all-day and night treatment, the TD [TD = temperature of (control)] was greater in bottom than that of other regions of the substrate. Between the day and night, no different TD values were observed under the all-day treatment, whereas under the night treatment there was difference with the greatest degree in the bottom of the substrate. During the hot temperature period, total numbers of days when substrate temperature was over $25^{\circ}C$ were 40, 23 and 27 days for the control, all-day, and night treatment, respectively, and the effect of lowering substrate temperature was therefore 42.5% and 32.5% for the all-day and night treatment, respectively, compared to that for the control. Root activity and leaf water potential of plants grown under the all-day treatment were significantly higher than those under the night treatment. The first flowering date in the all-day treatment was similar to that in the night treatment, but 4-5 day faster than in the control. Also, the number of fruits in both treatments was significantly higher than that in the control. However, there was no effect of root zone cooling on eliminating delay in fruiting caused by excessively higher air temperature (> $30^{\circ}C$), although the substrate temperature was reduced $18^{\circ}C$ to $5^{\circ}C$. These results suggest that the method of cooling root zone temperature need to be incorporated into the lowering growing temperature for growth and fruit set of health paprika.

Studies on the Shade Tolerance, Light Requirement, and Water Relations of Economic Tree Species(III) - Analysis of Pressure-Volume Curves on the Changes of Tissue Water Relations of Five Deciduous Hardwood Species Subjected to Artificial Shading Treatments - (주요경제수종(主要經濟樹種)의 내음성(耐陰性) 및 광선요구도(光線要求度)와 수분특성(水分特性)에 관한 연구(III) - 인공피음처리하(人工被陰處理下)에서 자라는 활엽수(闊葉樹) 5수종(樹種)의 수분특성(水分特性) 변화(變化)에 대한 P-V곡선(曲線) 분석(分析) -)

  • Choi, Jeong Ho;Kwon, Ki Won
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.4
    • /
    • pp.524-534
    • /
    • 2001
  • The pressure-volume curve parameters were investigated to elucidate the effects of shading treatment on the water relations of the one year old seedlings of Betula platyphylla var. japonica, Betula schmidtii, Zelkova serrata, Acer mono and Prunes sargentii subjected to five levels of artificial shading treatments. The osmotic potentials at full turgor(${\phi}_{{\pi}o}$) measured under full sunlight changed with species and growing season in the ranges of -1.04~-1.27MPa, -1.03~-1.48MPa, -0.94~-1.44MPa in first year treatment, and -0.90~-1.37MPa, -1.05~-1.79MPa, -0.99~-1.30MPa in second year treatment in June, July, and September, respectively. The osmotic potentials at full turgor increased with increment of shading level in the ranges of -0.90~-1.79MPa in full sunlight and -0.58~-1.23MPa in nearly full shading level(E) through the growing seasons in all the species studied. The osmotic potentials at turgor loss point(${\phi}_{{\pi}p}$) measured in full sunlight changed in the ranges of -1.64~-2.11MPa, -1.67~-2.15MPa, -1.47~-2.11MPa, and -1.45~-2.04MPa, -1.30~-2.00MPa, -1.28~-2.33MPa in June, July, and September of first and second years, respectively. Most of ${\phi}_{{\pi}p}$ measurements were lower within about 0.5MPa in comparison with those of ${\phi}_{{\pi}o}$. The measurements of ${\phi}_{{\pi}p}$ also increased with increment of shading level, and the differences in ${\phi}_{{\pi}p}$ among shading levels were generally greater than those in ${\phi}_{{\pi}o}$ by species and by growing season. Most of the osmotic potentials at turgor loss point as like as at full turgor were lowered in July than in June and September. The measurements of relative water content at turgor lass point(RWCp) in full sunlight were in the similar ranges of 81~88%, 71~86%, 75~84%, and 82~87, 72~84%, 76~86% in June, July, and September of first and second years, respectively. The RWCp were a little higher in A. mono and P. sargentii than in B. platyphylla var. japonica, B. schmidtii, and Z. serrata. The RWCp also decreased from 71~88% in full sunlight to 48~77% in nearly full shading treatment with increment of shading level. Even if there were some exceptions by species or by growing season, the shading effects on the changes in some P-V parameters were distinctly observed in the present study. The change in P-V parameters following shading treatment may be presumably inferred on the changes in solute accumulation, membrane elasticity, symplasmic water volume, and so on. But much more experiments should be necessarily continued for getting detailed informations on the physiological mechanism of shading effects relating to the changes in P-V parameters.

  • PDF

Stock Identification of Todarodes pacificus in Northwest Pacific (북서태평양에 서식하는 살오징어(Todarodes pacificus) 계군 분석에 대한 고찰)

  • Kim, Jeong-Yun;Moon, Chang-Ho;Yoon, Moon-Geun;Kang, Chang-Keun;Kim, Kyung-Ryul;Na, Taehee;Choy, Eun Jung;Lee, Chung Il
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.292-302
    • /
    • 2012
  • This paper reviews comparison analysis of current and latest application for stock identification methods of Todarodes pacificus, and the pros and cons of each method and consideration of how to compensate for each other. Todarodes pacificus which migrates wide areas in western North Pacific is important fishery resource ecologically and commercially. Todarodes pacificus is also considered as 'biological indicator' of ocean environmental changes. And changes in its short and long term catch and distribution area occur along with environmental changes. For example, while the catch of pollack, a cold water fish, has dramatically decreased until today after the climate regime shift in 1987/1988, the catch of Todarodes pacificus has been dramatically increased. Regarding the decrease in pollack catch, overfishing and climate changes were considered as the main causes, but there has been no definite reason until today. One of the reasons why there is no definite answer is related with no proper analysis about ecological and environmental aspects based on stock identification. Subpopulation is a group sharing the same gene pool through sexual reproduction process within limited boundaries having similar ecological characteristics. Each individual with same stock might be affected by different environment in temporal and spatial during the process of spawning, recruitment and then reproduction. Thereby, accurate stock analysis about the species can play an efficient alternative to comply with effective resource management and rapid changes. Four main stock analysis were applied to Todarodes pacificus: Morphologic Method, Ecological Method, Tagging Method, Genetic Method. Ecological method is studies for analysis of differences in spawning grounds by analysing the individual ecological change, distribution, migration status, parasitic state of parasite, kinds of parasite and parasite infection rate etc. Currently the method has been studying lively can identify the group in the similar environment. However It is difficult to know to identify the same genetic group in each other. Tagging Method is direct method. It can analyse cohort's migration, distribution and location of spawning, but it is very difficult to recapture tagged squids and hard to tag juveniles. Genetic method, which is for useful fishery resource stock analysis has provided the basic information regarding resource management study. Genetic method for stock analysis is determined according to markers' sensitivity and need to select high multiform of genetic markers. For stock identification, isozyme multiform has been used for genetic markers. Recently there is increase in use of makers with high range variability among DNA sequencing like mitochondria, microsatellite. Even the current morphologic method, tagging method and ecological method played important rolls through finding Todarodes pacificus' life cycle, migration route and changes in spawning grounds, it is still difficult to analyze the stock of Todarodes pacificus as those are distributed in difference seas. Lately, by taking advantages of each stock analysis method, more complicated method is being applied. If based on such analysis and genetic method for improvement are played, there will be much advance in management system for the resource fluctuation of Todarodes pacificus.

Comparison of Family Support and Mental Health Between the Rural and Urban Elderly (농촌과 도시지역 노인의 가족지지와 정신건강에 관한 비교)

  • Min, Kyung-Hwa;Kim, Sang-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 1995
  • This study is to compare family support and mental health between the rural and the urban elderly. In order to do that I collected the data through questioning 238 people in 3 urban areas in Busan and 201 people in 9 rural areas near Daegu. The degree of their family support is 36.70 on the average in the rural area and 40.77 in the urban area. The degree of family support of urban elderly is a little higher. According to general characters between the differences of family support in both areas, in the rural area there are differences in sex, age, whether they have a spouse or not, education level, financial state, number of children, number of co living, status of co living, subjective health status, amount of pocket money and how much they are participating in leisure activity. In the urban area there are differences in sex, whether they have a spouse or not, religion, financial state, number of co living, status of co living, subjective health status, amount of pocket money, how much they are participating in leisure activity and house pattern. In the stepwise multiple regression analysis the main variables that affect degree of family support in the rural area are age, whether they have a spouse or not and financial state which account for 33% of the total variance and in the urban area are subjective health status, financial state, whether they have a spouse or not and number of co-living which account for 35%. Health status is better in the urban area(average 36.87) than in the rural area(57.42). In each item the people whose mark was more than 75%(low) have Depression 8.4%, Somatization 8.0% in the urban area and Somatization 8.5%, Depression 8.5%, Anxiety 4.0%, Phobic anxiety 4.0%, Obsessive compulsive reaction 2.5%, Hostility 2.0%, Paranoid ideation 2.0%, Psychoticism 1.5% and Interpersonal sensitivity 1.5% in the rural area. In the mental health condition, on the basis of 4 points in both areas, the average is Somatization(rural : 1.69, urban : 1.51), Depression (rural : 1.64, urban : 1.37) and Obsessive compulsive reaction(rural : 1.33, urban : 0.99). According to the differences between mental health conditions by general characters, in the rural area the differences are presented in sex, age, whether they have a spouse or not, religion, education level, financial state, number of children, status of co living, subjective health status, amount of pocket money and how much they are participating in leisure activity, in the urban area the differences are presented in sex, whether they have a spouse or not, religion, financial state, number of co living, status of co living, subjective health status, house pattern, amount of pocket money and how much they are participating in leisure activity. In the stepwise multiple regression analysis the main variables that affect mental health condition in the rural are family support degree subjective health status, religion sex, age and financial state which account for 43% of the total and in the urban area are family support degree, subjective health status and financial state which account for 51%. In the matter of family support degree and mental health condition the rural area was -0.4555, of urban area was -0.6446. The rural area that has a high percentage in family support degree and mental health condition Depression was -0.5036, Psychoticism was -0.4265 in the urban area Psychoticism was -0.6452, Depression was -0.5955. Family support has a great influence on mental health of old people and family support and mental health condition can be different according to living area. So in their problems nursing intervention through family and nursing strategies according to living area should be established.

  • PDF

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals - (대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -)

  • Jung, Jong-Hyeon;Phee, Young-Gyu;Lee, Jun-Jung;Oh, In-Bo;Shon, Byung-Hyun;Lee, Hyung-Don;Yoon, Mi-Ra;Kim, Geun-Bae;Yu, Seung-do;Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.380-391
    • /
    • 2015
  • Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF