DOI QR코드

DOI QR Code

Exposure Assessments of Environmental Contaminants in Ansim Briquette Fuel Complex, Daegu(II) - Concentration distribution and exposure characteristics of TSP, PM10, PM2.5, and heavy metals -

대구 안심연료단지 환경오염물질 노출 평가(II) - TSP, PM10, PM2.5 및 중금속 농도분포 및 노출특성 -

  • Jung, Jong-Hyeon (Faculty of Health Science, Daegu Haany University) ;
  • Phee, Young-Gyu (Faculty of Health Science, Daegu Haany University) ;
  • Lee, Jun-Jung (Faculty of Health Science, Daegu Haany University) ;
  • Oh, In-Bo (Environmental Health Center, Ulsan University College of Medicine) ;
  • Shon, Byung-Hyun (Dept. of Environmental Engineering, Hanseo University) ;
  • Lee, Hyung-Don (Resource Recirculation Technology Research Center, R&D Division, Sudokwon Landfiil Site Management Corporation) ;
  • Yoon, Mi-Ra (National Institute of Environmental Research) ;
  • Kim, Geun-Bae (National Institute of Environmental Research) ;
  • Yu, Seung-do (National Institute of Environmental Research) ;
  • Min, Young-Sun (Department of Preventive Medicine, Dongguk University College of Medicine) ;
  • Lee, Kwan (Department of Preventive Medicine, Dongguk University College of Medicine) ;
  • Lim, Hyun-Sul (Department of Preventive Medicine, Dongguk University College of Medicine)
  • 정종현 (대구한의대학교 보건학부) ;
  • 피영규 (대구한의대학교 보건학부) ;
  • 이준정 (대구한의대학교 보건학부) ;
  • 오인보 (울산의대 환경보건센터) ;
  • 손병현 (한서대학교 환경공학과) ;
  • 이형돈 (수도권매립지관리공사 자원순환기술연구소 연구개발처) ;
  • 윤미라 (국립환경과학원) ;
  • 김근배 (국립환경과학원) ;
  • 유승도 (국립환경과학원) ;
  • 민영선 (동국의대 예방의학교실) ;
  • 이관 (동국의대 예방의학교실) ;
  • 임현술 (동국의대 예방의학교실)
  • Received : 2015.09.10
  • Accepted : 2015.09.25
  • Published : 2015.09.30

Abstract

Objectives: The objective of this study is to assess airborne particulate matter pollution and its effect on health of residents living near Ansim Briquette Fuel Complex and its vicinities. Also, this study measured and analyzed the concentration of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals which influences on the environmental and respiratory disease in Ansim Briquette Fuel Complex, Daegu, Korea. Methods: In this study, we analyzed various environmental pollutants such as particulate matter and heavy metals from Ansim Briquette Fuel Complex that adversely affected local residents's health. In particular, we verified the concentration distribution and characteristics of exposure for TSP, $PM_{10}$, and $PM_{2.5}$ among particulate matters, and heavy metals(Cd, Cr, Cu, Mn, Ni, Pb, Fe, Zn, and Mg). In that regard, the official test method on air pollution in Korea for analysis of particulate matter and heavy metal in atmosphere were conducted. The large capacity air sampling method by the official test method on air pollution in Korea were applied for sampling of heavy metals in atmosphere. In addition, we evaluated the concentration of seasonal environmental pollutants for each point of residence in Ansim Briquette Fuel Complex and surrounding area. The sampling measured periods for air pollutants were from August 11, 2013 to February 21, 2014. Furthermore, we measured and analyzed the seasonal concentrations(summer, autumn and winter). Results: The average concentration for TSP, $PM_{10}$, and $PM_{2.5}$ by direct influence area at Ansim Briquette Fuel Complex were 1.7, 1.4 and 1.9 times higher than reference region. In analysis results of seasonal concentrations for particulate matter in four direct influence and reference area, concentration levels for winter were generally somewhat higher than concentrations for summer and autumn. The average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were $0.0008{\pm}0.0004{\mu}g/Sm^3$, $0.0141{\pm}0.0163{\mu}g/Sm^3$, $0.0248{\pm}0.0059{\mu}g/Sm^3$, $0.0026{\pm}0.0011{\mu}g/Sm^3$, $0.0272{\pm}0.0084{\mu}g/Sm^3$, $0.4855{\pm}0.1862{\mu}g/Sm^3$, and $0.3068{\pm}0.0631{\mu}g/Sm^3$, respectively. In particularly, the average concentrations for Cd, Cr, Mn, Ni, Pb, Fe, and Zn in direct influence area at Ansim Briquette Fuel Complex were 1.9, 3.6, 2.1, 1.9, 1.4, 2.6, and 1.2 times higher than reference area, respectively. The continuous monitoring and management were required for some heavy metals such as Cr and Ni. Moreover, the average concentration in winter for particulate matter in direct influence area at Ansim Briquette Fuel Complex were generally higher than concentrations in summer and autumn. Also, average concentrations for TSP, $PM_{10}$, and $PM_{2.5}$ were from 1.5 to 2.0 times, 1.2 to 1.8 times, and 1.1 to 2.3 times higher than reference area, respectively. In results for seasonal atmospheric environment, TSP, $PM_{10}$, $PM_{2.5}$, and heavy metal concentrations in direct influence area were higher than reference area. Especially, the concentrations in C station were a high level in comparison with other area. Conclusions: In the results, some particulate matters and heavy metals were relatively high concentration, in order to understand the environmental pollution level and health effect in surrounding area at Ansim Briquette Fuel Complex. The concentration of some heavy metals emitted from direct influence area at Ansim Briquette Fuel Complex were relatively higher than reference area. In particular, average concentration for heavy metals in this study were higher than average concentrations in air quality monitoring station for heavy metal for 7 years in Deagu metropolitan region. Especially, the residents near Ansim Briquette Fuel Complex may be exposed to the pollutants(TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals, etc) emitted from the factories in Ansim Briquette Fuel Complex.

Keywords

References

  1. Choi BW, Jung JH, Choi WJ, Jeon CJ, Shon BH. Distribution characteristics of ambient heavy metals based on the pollution source and their carcinogenic risk assessment in Ulsan. Korea. Korean Society of Environmental Health. 2006;32(5):522-531
  2. Choi BW, Jung JH, Choi WJ, Shon BH, Oh KJ. Characteristics of the distribution of high ambient air pollutants with sources and weather condition in Ulsan. Korean Society of Environmental Health. 2006;32(4):324-335
  3. Cho SW, Min BC, Jung JH, Jeon YH, Kim DY, Jeong DY. A study on desulfurization by anthracite-bituminous coal blend combustion in a fluidized bed. Korean Society of Environmental Health. 1997;23(3):102-108
  4. Do HS. Characteristics assessment of trace element concentration in dust by facilities and areas in Daegu, Korea. Daegu Haany University. Ph.D Dissertation. 2011
  5. Jeon YH, Jung, JH, Shon BH, Cho SW, Oh KJ. A study on adsorption characteristics of $SO_2$ gas in a fixed bed adsorber. Korean Society of Environmental Engineers. 1996;18(8):961-969
  6. Jung, JH. A study on health hazard evaluation among residents in fuel complex, Ansim, Daegu. The Korean Society for Preventive Medicine. Fall Conference. 2014:324
  7. Jung, JH, Choi WJ, Leem HH, Park DS, Shon BH. Health and environmental risk assessment and weathering of stone cultural properties of air pollutants in Gyeongju and its vicinities(I). The Korea Academia- Industrial Cooperation Society. 2009;10(12):3740-3747 https://doi.org/10.5762/KAIS.2009.10.12.3740
  8. Jung, JH, Cho SW, Lim HS. Distribution characteristics of environmental contaminant at soil in an Industrial Complex Area. Clean Technology. 2012;18(4);200-208 https://doi.org/10.7464/ksct.2012.18.2.200
  9. Jung, JH, Cho SW, Shon BH, Jeon YH, Oh KJ. A study on the use of low-grade domestic anthracite by anthracite - bituminous coal blend combustion in a fluidized bed combustor. Journal of Environmental Science. 1997; 6(3):267-276
  10. Jung, JH, Cho SW, Shon BH, Kim YS, Oh KJ. A study on contaminant emission and combustion of anthracite - bituminous coal blend in a fluidized bed coal combustor. Korean Society of Environmental Health. 1996;22(3):28-36
  11. Jung JH. Effects of air pollutants on the health/environmental risk assessment and weathering of stone cultural properties in Gyeongju and its vicinities. Daegu Haany University. Ph.D Dissertation. 2008
  12. Jung, JH. Health risk assessments and concentrations of environmental pollutants in an industrial complex. Dongguk Uiversity. Ph.D Dissertation. 2012
  13. Jung, JH, Lee HD, Jeon SB, Yoo JK, Shon BH. Chemical characteristics and particle size distribution of $PM_{10}$ in Iron and Steel Industrial Complex. The Korea Academia- Industrial Cooperation Society. 2012;13(11):5601-5609 https://doi.org/10.5762/KAIS.2012.13.11.5601
  14. Jung, JH, Lee HD, Shon BH. Assessment of location of the air quality monitoring stations according to the analysis of wind sector division in Pohang. The Korea Academia-Industrial Cooperation Society. 2012;13(4): 1931-1938 https://doi.org/10.5762/KAIS.2012.13.4.1931
  15. Jung, JH, Oh IB, Phee YG, Nam MR, Lee HD et al. Effect zone of environmental pneumoconiosis and fugitive dust in an industrial complex and its vicinities. Journal of Korean Society of Occupational and Environmental Hygiene. Summer Conference. 2015:110
  16. Jung, JH, Phee YG, Shon BH, Yang WH, Kim JY et al. Distribution characteristics of pollutants according to elemental carbon and stable isotope ratio in an industrial complex and its vicinities. Journal of Korean Society of Occupational and Environmental Hygiene. Summer Conference. 2015:111
  17. Jung, JH, Phee YG, Oh IB, Shon BH, Yoon MR et al. Exposure characteristics of TSP, $PM_{10}$, $PM_{2.5}$, and heavy metals in an industrial complex and its vicinities. Journal of Korean Society of Occupational and Environmental Hygiene. Summer Conference. 2015:112
  18. Kang SW, Shim SH, Jung SH, Jung JH, Lee SS. Mercury emission characteristics from co-combustion of coal and sludge. Korean Society of Atmospheric Environment. 2012;28(2);182-189 https://doi.org/10.5572/KOSAE.2012.28.2.182
  19. National Institute of Environmental Research(NIER). The monitoring study on exposure level and biomarker of environmental pollutants in the Pohang industrial complex(5th annual report). 2010
  20. National Institute of Environmental Research(NIER). A study on health hazard evaluation among residents in fuel complex, Ansim, Daegu. 2014;1-491