• Title/Summary/Keyword: common and differential characteristics

Search Result 80, Processing Time 0.03 seconds

Application of VSI-EBG Structure to High-Speed Differential Signals for Wideband Suppression of Common-Mode Noise

  • Kim, Myunghoi;Kim, Sukjin;Bae, Bumhee;Cho, Jonghyun;Kim, Joungho;Kim, Jaehoon;Ahn, Do Seob
    • ETRI Journal
    • /
    • v.35 no.5
    • /
    • pp.827-837
    • /
    • 2013
  • In this paper, we present wideband common-mode (CM) noise suppression using a vertical stepped impedance electromagnetic bandgap (VSI-EBG) structure for high-speed differential signals in multilayer printed circuit boards. This technique is an original design that enables us to apply the VSI-EBG structure to differential signals without sacrificing the differential characteristics. In addition, the analytical dispersion equations for the bandgap prediction of the CM propagation in the VSIEBG structure are extracted, and the closed-form expressions for the bandgap cutoff frequencies are derived. Based on the dispersion equations, the effects of the impedance ratio, the EBG patch length, and via inductances on the bandgap of the VSI-EBG structure for differential signals are thoroughly examined. The proposed dispersion equations are verified through agreement with the full-wave simulation results. It is experimentally demonstrated that the proposed VSI-EBG structure for differential signaling suppresses the CM noise in the wideband frequency range without degrading the differential characteristics.

Development of Improved EMC Power Line Filter in New Type

  • Kim, Dong-Il;Kim, Eun-Mi;Ahn, Young-Sup;Jeon, Mi-Hwa
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.4
    • /
    • pp.153-157
    • /
    • 2008
  • Most of malfunctions in electronic equipment or systems controlled by processors is occurred by the differential- and common-mode noises, and the electrical fast transient (EFT). The International Electrotechnical Commission (IEC) has prepared the dummy signal to test the immunity level of the equipment. For the countermeasure against the differential- and common-mode noises, and the EFT, we designed, fabricated, and tested a new electromagnetic compatibility (EMC) filter, which is composed of feed-through capacitors and ferrite beads with high permeability. As a result, the filter showed excellent differential- and common-mode noises filtering, and immunity improving characteristics over the frequency band from 30 MHz to 1.5 GHz and 1.8 GHz, respectively.

A CMOS Op-amp Design of Improved Common Mode Feedback(CMFB) Circuit for High-frequency Filter Implementation (고주파용 필터구현을 위한 개선된 CMFB회로를 이용한 CMOS Op-amp 설계)

  • Lim, Dae-Sung;Choi, Young-Jae;Lee, Meung-Su;Kim, Dong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.479-482
    • /
    • 1993
  • A fully balanced differential amplifier can achieve high-gain wide-bandwidth characteristics. And also, Offset PSRR, CMRR and Noise performance of that are excellent, but these merits can be achieved only when the architecture holds fully balanced. Commonly, the fully balanced differential amplifier has a common mode feedback(CMFB) circuit in order to maintain the balance. This paper presents improved characteristics of the CMFB circuit and designs the wide-bandwidth CMOS Op-amp. The unity gain bandwidth of this Op-amp is 50MHz with the load capacitor 2pF, and the value of phase margin is $85^{\circ}$.

  • PDF

Balanced Mixer Based on Composite Right/Left-Handed Transmission Line Leaky-Wave Antenna (CRLH 전송 선로 리키 웨이브 안테나를 이용한 평형 믹서)

  • Kim, Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.985-991
    • /
    • 2008
  • This paper presents a novel balanced mixer receiver front-end design based on a metamaterial structure applicable to differential-/common-mode excitation. This metamaterial structure functions as a leaky-wave antenna and provides in-trinsic common-mode suppression. Low LO leakage and high RF to LO isolation are achieved without additional filters for LO and RF paths. The metamaterial is based on a unit-cell which under a differential-mode excitation behaves like a composite right/left-handed(CRLH) metamaterial. In contrast, the metamaterial unit-cell is below cut-off under a common-mode excitation. Experimental results are used to verify the proposed metamaterial's differential-/common-mode characteristics. The metamaterial is integrated with a balanced mixer design resulting in an operation frequency range of $1.96{\sim}2.40$ GHz with an optimum mixer conversion loss of 21.1 dB at 2,4 GHz.

Common Mode Filter Embedded in Flexible Printed Circuit Board for Multi-Function Cable (다기능 케이블을 위한 연성 회로 기판에 내장된 공통 모드 필터)

  • Byun, Jin-Do;Jung, Sang-Woon;Lee, Keun-Hyung;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.343-351
    • /
    • 2008
  • In this paper, a spiral shaped common mode filter(CMF) embedded in a flexible printed circuit board(FPCB) is proposed for a multi-function cable. The CMF embedded in a FPC cable presents a new concept as a multi-function cable by the common mode rejection characteristics without a surface mounted device(SMD) CMF. The embedded CMF has a wideband common mode rejection bandwidth and an enhanced differential mode characteristics compared to conventional CMFs that use a magnetic material such as a ferrite of high loss. The proposed CMF of 3 turn inductors has a common mode rejection bandwidth from 0.4 GHz to 3.12 GHz and has 1.95 dB at 3 GHz, 6.97 dB at 8 GHz improvements of a differential mode insertion loss compared to the commercial LTCC(Low Temperature Co-fire Ceramics) CMFs.

Metamaterial CRLH Structure-based Balun for Common-Mode Current Indicator

  • Kahng, Sungtek;Lee, Jinil;Kim, Koon-Tae;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.301-306
    • /
    • 2014
  • We proposed a new PCB-type 'common-mode current($I_c$) and differential-mode current($I_d$) detector' working for fast detection of $I_c$ and $I_d$ from the differential-mode signaling, with miniaturization effect and possibility of cheaper fabrication. In order to realize this device, we suggest a branch-line-coupler balun having a composite right- and left-handed(CRLH) one-layer microstrip phase-shifting line as compact as roughly ${\lambda}_g/14$. The presented balun obviously is different from the conventional bent-&-folded delay lines or slits on the ground for coupling the lines on the top and bottom dielectrics. As we connect the suggested balun output ports of the differential-mode signal lines via the through-port named U and coupled-port named L, $I_c$ and $I_d$ will appear at port ${\Delta}$ and port ${\Sigma}$ of the present device, in order. The validity of the design scheme is verified by the circuit-and numerical electromagnetic analyses, and the dispersion curve proving the metamaterial characteristics of the geometry. Besides, the examples of the $I_c$ and $I_d$ indicator are observed as the even and odd modes in differential-mode signal feeding. Also, the proposed device is shown to be very compact, compared with the conventional structure.

Differential Diagnosis of Thick Myocardium according to Histologic Features Revealed by Multiparametric Cardiac Magnetic Resonance Imaging

  • Min Jae Cha;Cherry Kim;Chan Ho Park;Yoo Jin Hong;Jae Min Shin;Tae Hoon Kim;Yoon Jin Cha;Chul Hwan Park
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.581-597
    • /
    • 2022
  • Left ventricular (LV) wall thickening, or LV hypertrophy (LVH), is common and occurs in diverse conditions including hypertrophic cardiomyopathy (HCM), hypertensive heart disease, aortic valve stenosis, lysosomal storage disorders, cardiac amyloidosis, mitochondrial cardiomyopathy, sarcoidosis and athlete's heart. Cardiac magnetic resonance (CMR) imaging provides various tissue contrasts and characteristics that reflect histological changes in the myocardium, such as cellular hypertrophy, cardiomyocyte disarray, interstitial fibrosis, extracellular accumulation of insoluble proteins, intracellular accumulation of fat, and intracellular vacuolar changes. Therefore, CMR imaging may be beneficial in establishing a differential diagnosis of LVH. Although various diseases share LV wall thickening as a common feature, the histologic changes that underscore each disease are distinct. This review focuses on CMR multiparametric myocardial analysis, which may provide clues for the differentiation of thickened myocardium based on the histologic features of HCM and its phenocopies.

Differential Diagnosis of Hirschsprung's Disease (Hirschsprung's Disease의 감별 진단)

  • Yoo, Soo-Young
    • Advances in pediatric surgery
    • /
    • v.8 no.1
    • /
    • pp.54-61
    • /
    • 2002
  • Hirschsprung's disease (HD) is usually diagnosed in the newborn period and early infancy. The common presentation of HD in newborns consists of a history of delayed passage of meconium within the first 48 hours of life. The differential diagnosis in newborns is one of the clinical challenges of this disorder. A number of medical conditions which cause functional obstruction of the intestines are easily excluded. Neonates with meconium ileus, meconium plug syndrome, distal ileal atresia and low imperforate anus often present in a manner similar to those with HD in the first few days of life. Abdominal radiographs may help to diagnose complete obstruction such as intestinal atresia. Microcolon on contrast enema can be shown in cases with total colonic aganglionosis, ileal atresia or meconium ileus. Suction rectal biopsy or frozen section biopsy at operation is essential for differential diagnosis in such cases. HD is also considered in any child who has a history of constipation regardless of age. Older children with functional constipation may have symptoms that resemble those of HD and contrast enema is usually diagnostic. However, children with other motility disorders generally referred to as chronic idiopathic intestinal pseudoobstruction present with very similar symptoms and radiographic findings. These disorders are classified according to their histologic characteristics.; visceral myopathy, visceral neuropathy, intestinal neuronal dysplasia (IND), hypoganglionosis, immature ganglia, internal sphincter achalasia. Therefore, the workup for motility disorders should include rectal biopsy not only to confirm the presence of ganglion cells but also evaluate the other pathologic conditions.

  • PDF

Perceptional Characteristics of Effective Safety Signs Corresponding to International Criteria (국제 기준에 부합하는 효과적 안전표지의 지각 특성)

  • Lim, Hyeon-Kyo;Park, Young-Won;Jung, Gwang-Tae
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.111-118
    • /
    • 2008
  • In usual safety signs are final means to transmit hazard information so that the importance of them cannot be emphasized too much. Nevertheless, in Korea, few people are interested in functions of safety signs so that evaluation of safety signs are seldom committed. This research was conducted to evaluate and compare perceptional characteristics of safety signs, especially "Fall" signs, by Semantic Differential Method and Multi-dimensional Scaling Method, with undergraduate students as well as industrial workers. According to research results on several signs evaluated high through suggested procedure, action inducibility was different for students majoring in different sciences, but it had common elements in the sense of 'openness' or 'arrangements'. Besides, perceptional images on safety signs were mainly recognized with bases of 'arrangement' for student group and 'simplicity' for industrial workers, respectively, and their maps corresponded well with each other by partial rotating so that students and workers seemed to recognize safety signs with similar factors though their name might be different. However, since perceptional characteristics including image map, comprehensibility, and action inducibility were similar for student group whereas those were not for worker group, it was concluded that the test for action inducibility would be absolutely necessary for safety signs for workers' group.

Characteristics of On-Board Broadband Antenna for 2.4 GHz Band (2.4 GHz 대역의 On-Board Broadband 안테나 특성)

  • Lee, Sang-Seok;Lee, Young-Hun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.1
    • /
    • pp.39-46
    • /
    • 2014
  • In this paper, to operate 2.4 GHz Inverted-L antenna with On-Board Broadband characteristics is proposed. The antenna was designed on the system board, the bandwidth by adjusting the reactance of the antenna that was formed common-mode and differential-mode on the antenna stubs has been improved. The system size is $80mm{\times}60mm$, the size of the antenna was limited to $30mm{\times}60mm$, the thickness of FR4 dielectric substrate is 0.8 mm, FR4 dielectric constant 4.4 is used. The experimental results, the bandwidth from 17.2 to 24.1 %, the gain is 3.01~4.71 dB, omni-directional radiation pattern characteristics were obtained. By a mobile terminal design applying the results of the paper, the handset's price competitiveness and production efficiency can be improved.