Preliminary Feasibility Study for Commercial DME Plant Project (DME 상용화 플랜트 예비 타당성 조사)

  • Mo, Younggi;Kang, Minseo;Song, Taekyoung;Baek, Youngsoon;Cho, Wonjun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.2
    • /
    • pp.173-182
    • /
    • 2014
  • Dimethyl ether (DME) is a new clean fuel as an environmentally-being energy resources. DME has similar characteristics to those of LPG and can be substituted Diesel fuel. KOGAS has investigated and developed new innovative DME synthesis process from synthesis gas with KOGAS's own technologies. KOGAS had finished the construction of 10ton/day DME demonstration plant in 2008, we have established the basic design of commercial plant which can produce 3,000ton/day DME. Specifically, an economic model for a commercial DME project will be presented. It accounts for all the major cost factors that are considered in a commercial scale project as the model input for performing cash flow analysis, after which key economic indicators are produced including the internal rate of return (IRR), net present value (NPV). Sensitivity analysis is performed to identify dominant cost factors to the project economics and quantify their impact. The inputs to the economic analysis will be based on representative cost factors from the commercial-scale design of KOGAS' direct DME process supplemented by literature data. Case study results will be presented based on recent commercialization projects.

Large-Scale Culture of Hepatitis A Virus in Human Diploid MRC-5 Cells and Partial Purification of the Viral Antigen for Use as a Vaccine

  • Kim, Hyun-Seok;Chung, Yong-Ju;Jeon, Yeong-Joong;Lee, Sung-Hee
    • Journal of Microbiology and Biotechnology
    • /
    • v.9 no.4
    • /
    • pp.386-392
    • /
    • 1999
  • A large-scale culture of hepatitis A virus in human diploid MRC-5 cells was conducted. In a roller bottle culture, the virus was grown to a maximum titer in 3 weeks after infection. Over 95% of the cell-associated virus was excreted after culturing the infected cells in suspension media without fetal bovine serum for 3 days. The cultured virus was inactivated with formalin, concentrated by ultrafiltration, and partially purified by ultracentrifugation in a non-ionic gradient medium of Renocal. Two separate peak fractions showing high anti-HAY ELISA titer were pooled and about 40% of HAV antigen was recovered by this purification procedure. Of the partially purified vaccine, the protein pattern in SDS-PAGE and immunogenicity in mice were compared with a commercial HAV vaccine. In SDS-PAGE, the purified vaccine in this study and the commercial vaccine showed almost the same protein pattern. The seroconversion rate of the purified vaccine in mice was not different from that of the commercial vaccine. Therefore, we could prepare a good grade of HAV vaccine by a simple purification procedure although the purification itself was not completed.

  • PDF

Development of a Low -Cost and Precise Liquid Metering Device for Automatic Nutrient-Solution Control (양액 자동조제용 액제 정밀계량 장치 개발)

  • 이정훈;류관희;이규철
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1997.12a
    • /
    • pp.255-262
    • /
    • 1997
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. Those parts were controlled by personal computer with time-based odoff control method. To verify the performance of the developed metering device, the relationship between operating time and discharge was examined and the accuracy of the developed metering device was compared with commercial metering pumps. The results of this study are as follows. 1. The correlation coefficient between the flow rate and operating time was 0.9999, and the linear regression equation computed was y=21.759x, where y is the discharge(g) and x is the operating time(s). 2. The developed device has greater accuracy than commercial metering pumps in terms of the full-scale error. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3 %, $\pm$2.45 % and $\pm$1.38 % respectively. 3. Above results show developed metering device is a useful tool for nutrient-solution control system.

  • PDF

Physicochemical Properties and Consumer Acceptability of Commercial Gang-jeong (시판 강정류의 이화학적 특성 및 소비자 기호도에 관한 연구)

  • Ryu, Ji-Hye;Kwon, Yong-Suk;Kim, Kyoung-Mi;Lee, Jin-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.29 no.6
    • /
    • pp.637-647
    • /
    • 2014
  • This study was conducted to examine the physicochemical properties and consumer acceptability of commercial Gang-jeong. The samples used in this study were nine different Gang-jeong as commercial products. To accomplish this research, the physicochemical properties of nine samples, including moisture, crude lipid, sugar contents, acid value, color values, and texture, were measured. In addition, consumer panels evaluated the overall acceptability, appearance, flavor, sweetness, and texture of samples using a 9-point Likert type scale as well as the perceived intensities of sweetness and rancid odor by a 9-point Just-About-Right (JAR) scale. All data were statistically analyzed using One-way ANOVA, Principle Component Analysis, Hierarchical Cluster Analysis, and Pearson's Correlation Analysis. All physicochemical properties were significantly different among the samples (p<0.001). Analyses of consumer acceptability and JAR ratings of the nine samples showed significant differences (p<0.001).

Study on the Process Condition for Producing Propylene Carbonate in Commercial (상업적으로 프로필렌카보네이트를 제조하기 위한 공정 조건 연구)

  • Jin, Sang Hyun;Lee, Hak Beum;Back, Jea Beom
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.58-62
    • /
    • 2020
  • Among the exhaust gas, Carbon dioxide which is a causative factor in greenhouse effect. We study for synthesis of propylene carbonate with carbon dioxide which is captured and utilized in commercially valuable. The Experiment was proceeded as pilot scale with using homogeneous organic catalyst which is able to produce propylene carbonate in commercial and reaction conditions. Optimization condition for concentration of catalyst and reaction temperature, pressure was studied. We confirm that this process is eco-friendly method and commercial application due to the mild condition and also catalyst has a competitive price, reusability.

A Study on the Improvement Plan for the Revitalization of Commercial Facilities in Railway Station Building - Focused on Ecute of Commercial Facilities of Railway Station Building in Japan - (철도 역내 상업시설의 이용 활성화를 위한 개선방안 모색 - 일본의 역내 상업시설 'ecute'에 관한 고찰을 중심으로 -)

  • Moon, Suh-hyun
    • Korean Institute of Interior Design Journal
    • /
    • v.26 no.3
    • /
    • pp.101-112
    • /
    • 2017
  • Based on an analysis of the characteristics of "Ecute" of the East Japan Railway Company (JR East) that planned the world's first large scale commercial facilities inside a ticket gate (paid-area including waiting room and platforms), the present study proposes a brand development of commercial facilities inside aged railway stations, where only basic railway business have been provided focusing on passenger transportation, by renewing the definition of railway commercial facilities and presenting a detailed planning and the direction of the operation system. A list of practical tasks that can be carried out in academia, planning and operation / management to facilitate the revitalization of the use of commercial facilities inside railway stations are as follows: 1) the setting of a wide scope for the revitalization of railway commercial facilities around the railway station focusing on private-funded stations in addition to existing stations; a setup of the direct scope of commercial development in the practical railway operation for passengers and stations in terms of external research, and a corresponding shift in thinking in terms of internal research 2) development of under used spaces such as the transfer area (Gongdeok Seoul Wangsimri Station are first target stations where more than four subway lines intersect) 3) brand establishment through improvement strategies for image and symbolism specialized for railway stations 4) rent of suitable business stores and layout of commercial facilities by analysis of passenger move pattern 5) development of commercial facilities which can attract customers by displaying various products, as well as finding a way to develop them in to a base facility that connects to local infrastructures 6) providing advertisement and management system for continual maintenance, and 7) brand specialization through unique storytelling and design plan that stimulates sensibility. The above study results can be utilized as a starting point for design brand awareness about commercial facilities in railway stations in Korea, which can be developed further to improve station image and passenger convenience, as well as to increase the revenue of railway businesses.

Advances in electrodeionization technology for ionic separation - A review

  • Khoiruddin, Khoiruddin;Hakim, A.N.;Wenten, I.G.
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.87-108
    • /
    • 2014
  • Electrodeionization (EDI), which combines electrodialysis (ED) and conventional ion-exchange (IX), is a mature process which has been applied since more than twenty years on commercial use for the production of ultrapure water (UPW). Eliminating chemical regeneration is the main reason for its commercial success. The increase in acceptance of EDI technology has led to an installation of very large plant as the commercial state of the art that produces $1,500m^3/h$ of water for high pressure steam boiler. More recently, EDI system has found a number of new interesting applications in wastewater treatment, biotechnology industry, and other potential field. Along with further growth and wider applications, the development of stack construction and configuration are also become a concern. In this paper, the principle of EDI process is described and its recent developments, commercial scale, and various applications are pointed out.

A Study on the Flow Characteristic of Lubrication Oil System in Manual Transmission System for Large Commercial Vehicle (대형 상용차용 수동변속기내 윤활시스템의 유동특성에 관한 연구)

  • Yi, Chung-Seob;Suh, Jeong-Se;Song, Chul-Ki;Shin, Yoo-In;Yun, Ji-Hun;Chung, Kyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2010
  • This study has conducted numerical analysis for lubrication system of transmission for commercial vehicle. The lubrication oil system in transmission can be applied to a large scale commercial vehicle which is over 15tons. The flow rate of lubricating oil has been obtained for each of branch port from the lubrication pipe. The results from numerical simulation are mainly suggested for the mass flow rate of lubrication oil in the rotating main shaft of transmission system. It has been found that the mass flow rate from oil hole increased with an rotating rate of main shaft. The flow characteristic from oil hole has been presented for the lubricating system in the manual transmission.

Performance Analysis, Real Time Simulation and Control of Medium-Scale Commercial Aircraft Turbofan Engine

  • Kong, Chang-Duk;Jayoung Ki;Chung, Suk-Chou
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.776-787
    • /
    • 2001
  • The turbofan engine performance analysis for a medium scale commercial aircraft was carried out and the LQR control scheme for performance optimization was studied. By using scaled component maps from well-known CF6 engine characteristics, the steady-state performance analysis result was compared with BR715-56 engine performance data. The transient performance analysis was performed with four fuel schedules. The linear simulation was done at the maximum take-off condition. The real time linear simulation was performed by interpolation of the system matrices, which used the least square method as the function of LPC rotational speed. By using linear system matrices of design point, the LQR controller which used control variables for the fuel flow and the LPC bleed air was designed.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF