• Title/Summary/Keyword: combined type

Search Result 2,289, Processing Time 0.027 seconds

Research and Development Trends of PV Thermal Combined Systems (PV Thermal 복합시스템의 국내외 연구 개발 동향)

  • Kim, Jin-Hee;Lee, Kang-Rock;Yang, Youn-Wan;Kim, Jun-Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.588-592
    • /
    • 2006
  • PV Thermal combined system produces the electricity and thermal energy which are needed for buildings. The system removes heat from PV module through air or liquid, so that its efficiency will be improved. The heat as the forms of hot air or hot water can be utilized for building use, like space heating and hot water. This paper describes the concept of PV Thermal combined system and its research and development trend at local and international levels. This materials can be used as a fundamental study source about PV Thermal combined system to apply fur building space heating.

  • PDF

Two-stage Ear Reconstruction with Canaloplasty in Congenital Microtia (외이도성형술을 병행한 선천작은귀증의 두단계 재건)

  • Kim, Jong Yeop;Cho, Byung Chae;Lee, Sang Heun
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.53-60
    • /
    • 2006
  • The current authors performed two-stage ear reconstruction of microtia using autogenous costal cartilage combined with canaloplasty of the acoustic meatus in a team approach. In the first stage, lobule transposition, fabrication of the cartilage framework, and implantation of the framework were peformed. In the second stage, elevation of the auricle, cartilage graft for posterior auricular sulcus, coverage with the mastoid fascia flap and skin graft, and concha excavation were performed. The canaloplasty was combined simultaneously in patients with radiologic and audiometric evidence of cochlear function in the second stage. A total of 36 consecutive patients with congenital microtia were treated from 1998 to 2003. Among them, 27 patients(male: 18, female: 9) ranging from 7 to 43 years old were combined with canaloplasty. The follow-up period was one year to 5 years. Thirteen patients exhibited improved hearing over 30 dB PTA(pure tone average), 9 patients below 30 dB, and 5 patients with no improvement. Complications related to the canaloplasty were chronic drainages of the auditory meatus and meatal stenosis. Lobule type deformity combined with the canaloplasty showed higher complications than concha type. Therefore, in the lobule type, meticulous manipulation is necessary to reduce complications after the canaloplasty.

Immediate Effects of Combined Stretching Exercise and Therapeutic Ultrasound on the Muscles Around the Neck in Tension-type Headache Patients (치료적 초음파를 결합한 뻗침운동이 긴장성 두통 환자의 목주변 근육에 미치는 즉각적인 효과)

  • Heo, Jae-Won;Park, Sam-Heon
    • Journal of muscle and joint health
    • /
    • v.29 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • Purpose: This study aimed to provide objective and basic data for an effective treatment method by examining changes in the mechanical properties of muscles and the degree of tenderness when a combination of stretching exercise and ultrasound therapy is applied to patients with tension headaches. Methods: The participants were classified into two groups based on the intervention received: the therapeutic ultrasound combined with suboccipital stretching (n=15, experimental group) and infrared combined with suboccipital stretching (n=15, control group) groups. The intragroup differences in mechanical muscle properties and modified total tenderness score were compared and analyzed. Results: The comparison and analyses of the changes in muscle tone and stiffness revealed statistically significant intragroup decreases in the upper trapezius and suboccipitalis in the experimental group. Similarly, the comparison and analyses of the changes in muscle stiffness revealed statistically significant intragroup decreases in the upper trapezius in the control group. Conclusion: Therapeutic ultrasound combined with suboccipitalis stretching effectively increased the flexibility of the muscles around the cervical vertebrae and reduced muscle tension and stiffness in tension-type headache patients

Model Classification and Evaluation of Measurement Uncertainty (측정 불확도 모형 분류 및 평가)

  • Choi, Sung-Woon
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.145-156
    • /
    • 2007
  • This paper is to propose model classification and evaluation of measurement uncertainty. In order to obtain type A and B uncertainty, variety of measurement mathematical models are illustrated by example. The four steps to evaluate expanded uncertainty are indicated as following; First, to get type A standard uncertainty, measurement mathematical models of single, double, multiple, design of experiment and serial autocorrelation are shown. Second, to solve type B standard uncertainty measurement mathematical models of empirical probability distributions and multivariate are presented. Third, type A and B combined uncertainty, considering sensitivity coefficient, linearity and correlation are discussed. Lastly, expanded uncertainty, considering degree of freedom for type A, B uncertainty and coverage factor are presented with uncertainty budget. SPC control chart to control expanded uncertainty is shown.

Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment (중·소규모 생활오수 처리를 위한 합병정화조 개발)

  • Rim, Jay-Myoung;Han, Dong-Joon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules (액체식 PVT 복합모듈의 유형별 성능 비교 분석)

  • Kim, Jin-Hee;Kang, Jun-Gu;Kim, Jun-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

Osteogenesis imperfecta and combined orthodontics and orthognathic surgery: a case report on two siblings

  • Kim, Dong-Young;Baik, Unbong;Jeon, Ju-Hong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.1
    • /
    • pp.70-77
    • /
    • 2020
  • Osteogenesis imperfecta is a heterogeneous group of connective tissue diseases that is predominantly characterized by bone fragility and skeletal deformity. Two siblings with undiagnosed type I osteogenesis imperfecta underwent orthognathic surgery for the treatment of facial asymmetry and mandibular prognathism. The authors report two cases of combined orthodontics and orthognathic surgery in patients with type I osteogenesis imperfecta, mandibular prognathism, and facial asymmetry.

Univentricular heart: a report of 2 cases (단심실증의 수술치험 2)

  • 박이태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.625-631
    • /
    • 1984
  • A modified Fontan procedure was performed on two patients with Univentricular heart. The first patient had UVH of right ventricular type with trabecular pouch and had various associated anomalies, such as common atrium, common atrioventricular valve and combined pulmonary stenosis. The second patient had UVH of left ventricular type with outlet chamber and the associated anomalies were atrial septal defect, tricuspid stenosis and combined pulmonary stenosis. Postoperative hemodynamic insufficiency, fluid retention and renal insufficiency were occurred in the first patient, but relieved with the aid of inotropics and vasodilators. We thought that the good postoperative course and surgical result were gained from the widely patent atriopulmonary anastomosis.

  • PDF

The comparison of the output characteristics of 2-DOF PID controller in the multivariable flow control system with delayed time (지연시간을 갖는 다변수 유량제어 시스템의 2-자유도 PID 제어기 특성 비교)

  • Kim, Dong-Hwa
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.744-752
    • /
    • 1999
  • In this paper, we studied the response characteristics of $\alpha$, $\beta$ separated type, combined type, PI typed, and feedforward type in 2DOF-PID controller through the simulation and the experiments designed with the multivariable flow control system. The parameters $\alpha$ and $\beta$ give an affect to characteristics of controller in separated type but $\gamma$ does not give an affect to the characteristics of 2-DOF PID. The more $\beta$ increases, the more overshoot decreases and especially, in case of PI type represent clearly. The $\alpha$, $\beta$ separated type has a very small overshoot and its magnitudes in 2-DOF PID onctroller increases in order of $\alpha$, $\beta$ combined type, PI type, feedforward type, conventional type. The response characteristics of simulation are similar to that of experiments but the experimental characteristics in the multivariable flow control system has the delayed response. The time delay of response in experiments depends on 2-DOF parameter $\alpha$, $\beta$, $\gamma$ and the overshoot increase as the $\alpha$, $\beta$, $\gamma$ increase. So, we can have a satisfactory response by tuning D gain.

  • PDF