• 제목/요약/키워드: combined type

검색결과 2,289건 처리시간 0.026초

PV Thermal 복합시스템의 국내외 연구 개발 동향 (Research and Development Trends of PV Thermal Combined Systems)

  • 김진희;이강록;양연원;김준태
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.588-592
    • /
    • 2006
  • PV Thermal combined system produces the electricity and thermal energy which are needed for buildings. The system removes heat from PV module through air or liquid, so that its efficiency will be improved. The heat as the forms of hot air or hot water can be utilized for building use, like space heating and hot water. This paper describes the concept of PV Thermal combined system and its research and development trend at local and international levels. This materials can be used as a fundamental study source about PV Thermal combined system to apply fur building space heating.

  • PDF

외이도성형술을 병행한 선천작은귀증의 두단계 재건 (Two-stage Ear Reconstruction with Canaloplasty in Congenital Microtia)

  • 김종엽;조병채;이상흔
    • Archives of Plastic Surgery
    • /
    • 제33권1호
    • /
    • pp.53-60
    • /
    • 2006
  • The current authors performed two-stage ear reconstruction of microtia using autogenous costal cartilage combined with canaloplasty of the acoustic meatus in a team approach. In the first stage, lobule transposition, fabrication of the cartilage framework, and implantation of the framework were peformed. In the second stage, elevation of the auricle, cartilage graft for posterior auricular sulcus, coverage with the mastoid fascia flap and skin graft, and concha excavation were performed. The canaloplasty was combined simultaneously in patients with radiologic and audiometric evidence of cochlear function in the second stage. A total of 36 consecutive patients with congenital microtia were treated from 1998 to 2003. Among them, 27 patients(male: 18, female: 9) ranging from 7 to 43 years old were combined with canaloplasty. The follow-up period was one year to 5 years. Thirteen patients exhibited improved hearing over 30 dB PTA(pure tone average), 9 patients below 30 dB, and 5 patients with no improvement. Complications related to the canaloplasty were chronic drainages of the auditory meatus and meatal stenosis. Lobule type deformity combined with the canaloplasty showed higher complications than concha type. Therefore, in the lobule type, meticulous manipulation is necessary to reduce complications after the canaloplasty.

치료적 초음파를 결합한 뻗침운동이 긴장성 두통 환자의 목주변 근육에 미치는 즉각적인 효과 (Immediate Effects of Combined Stretching Exercise and Therapeutic Ultrasound on the Muscles Around the Neck in Tension-type Headache Patients)

  • 허재원;박삼헌
    • 근관절건강학회지
    • /
    • 제29권1호
    • /
    • pp.11-17
    • /
    • 2022
  • Purpose: This study aimed to provide objective and basic data for an effective treatment method by examining changes in the mechanical properties of muscles and the degree of tenderness when a combination of stretching exercise and ultrasound therapy is applied to patients with tension headaches. Methods: The participants were classified into two groups based on the intervention received: the therapeutic ultrasound combined with suboccipital stretching (n=15, experimental group) and infrared combined with suboccipital stretching (n=15, control group) groups. The intragroup differences in mechanical muscle properties and modified total tenderness score were compared and analyzed. Results: The comparison and analyses of the changes in muscle tone and stiffness revealed statistically significant intragroup decreases in the upper trapezius and suboccipitalis in the experimental group. Similarly, the comparison and analyses of the changes in muscle stiffness revealed statistically significant intragroup decreases in the upper trapezius in the control group. Conclusion: Therapeutic ultrasound combined with suboccipitalis stretching effectively increased the flexibility of the muscles around the cervical vertebrae and reduced muscle tension and stiffness in tension-type headache patients

측정 불확도 모형 분류 및 평가 (Model Classification and Evaluation of Measurement Uncertainty)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.145-156
    • /
    • 2007
  • This paper is to propose model classification and evaluation of measurement uncertainty. In order to obtain type A and B uncertainty, variety of measurement mathematical models are illustrated by example. The four steps to evaluate expanded uncertainty are indicated as following; First, to get type A standard uncertainty, measurement mathematical models of single, double, multiple, design of experiment and serial autocorrelation are shown. Second, to solve type B standard uncertainty measurement mathematical models of empirical probability distributions and multivariate are presented. Third, type A and B combined uncertainty, considering sensitivity coefficient, linearity and correlation are discussed. Lastly, expanded uncertainty, considering degree of freedom for type A, B uncertainty and coverage factor are presented with uncertainty budget. SPC control chart to control expanded uncertainty is shown.

중·소규모 생활오수 처리를 위한 합병정화조 개발 (Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment)

  • 임재명;한동준
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

액체식 PVT 복합모듈의 유형별 성능 비교 분석 (The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules)

  • 김진희;강준구;김준태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.792-797
    • /
    • 2009
  • The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.

  • PDF

Osteogenesis imperfecta and combined orthodontics and orthognathic surgery: a case report on two siblings

  • Kim, Dong-Young;Baik, Unbong;Jeon, Ju-Hong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제46권1호
    • /
    • pp.70-77
    • /
    • 2020
  • Osteogenesis imperfecta is a heterogeneous group of connective tissue diseases that is predominantly characterized by bone fragility and skeletal deformity. Two siblings with undiagnosed type I osteogenesis imperfecta underwent orthognathic surgery for the treatment of facial asymmetry and mandibular prognathism. The authors report two cases of combined orthodontics and orthognathic surgery in patients with type I osteogenesis imperfecta, mandibular prognathism, and facial asymmetry.

단심실증의 수술치험 2 (Univentricular heart: a report of 2 cases)

  • 박이태
    • Journal of Chest Surgery
    • /
    • 제17권4호
    • /
    • pp.625-631
    • /
    • 1984
  • A modified Fontan procedure was performed on two patients with Univentricular heart. The first patient had UVH of right ventricular type with trabecular pouch and had various associated anomalies, such as common atrium, common atrioventricular valve and combined pulmonary stenosis. The second patient had UVH of left ventricular type with outlet chamber and the associated anomalies were atrial septal defect, tricuspid stenosis and combined pulmonary stenosis. Postoperative hemodynamic insufficiency, fluid retention and renal insufficiency were occurred in the first patient, but relieved with the aid of inotropics and vasodilators. We thought that the good postoperative course and surgical result were gained from the widely patent atriopulmonary anastomosis.

  • PDF

지연시간을 갖는 다변수 유량제어 시스템의 2-자유도 PID 제어기 특성 비교 (The comparison of the output characteristics of 2-DOF PID controller in the multivariable flow control system with delayed time)

  • 김동화
    • 제어로봇시스템학회논문지
    • /
    • 제5권6호
    • /
    • pp.744-752
    • /
    • 1999
  • In this paper, we studied the response characteristics of $\alpha$, $\beta$ separated type, combined type, PI typed, and feedforward type in 2DOF-PID controller through the simulation and the experiments designed with the multivariable flow control system. The parameters $\alpha$ and $\beta$ give an affect to characteristics of controller in separated type but $\gamma$ does not give an affect to the characteristics of 2-DOF PID. The more $\beta$ increases, the more overshoot decreases and especially, in case of PI type represent clearly. The $\alpha$, $\beta$ separated type has a very small overshoot and its magnitudes in 2-DOF PID onctroller increases in order of $\alpha$, $\beta$ combined type, PI type, feedforward type, conventional type. The response characteristics of simulation are similar to that of experiments but the experimental characteristics in the multivariable flow control system has the delayed response. The time delay of response in experiments depends on 2-DOF parameter $\alpha$, $\beta$, $\gamma$ and the overshoot increase as the $\alpha$, $\beta$, $\gamma$ increase. So, we can have a satisfactory response by tuning D gain.