• 제목/요약/키워드: combined protection

검색결과 382건 처리시간 0.022초

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

정압기지에 대한 산불화재 영향평가 (Effect Evaluation of Forest Fire on Governor Station)

  • 장서일;차순철;강경식
    • 대한안전경영과학회지
    • /
    • 제9권2호
    • /
    • pp.49-57
    • /
    • 2007
  • This Study is to suggest a method of effect evaluation of forest fire on governor station in shrub land. Theoretically, to evaluate effects of forest fire, it is combined that Spread Rate of Forest Fire, Flame Model, and Thermal Radiation Effects Model; i.e. a travel time of forest fire is calculated by Spread Rate of Forest Fire, fire-line intensity is calculated by Flame Model, and effects of fire-line intensity is affected by Thermal Radiation Effects Model. With the aforementioned method, we could carry out the effect evaluation of forest fire on governor station in shrub land and could distinguish scenarios to need protection plan from all scenarios.

Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터 (Single Stage PFC Flyback Converter Using Top Switch)

  • 임창섭;권순걸;이현우;김은수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF

OF 케이블 계통에서 과도상태시 에너지 특성 검토 (A Study on Energy Characteristics in Transient States of OF Cable Systems)

  • 정채균;이종범;강지원;이동일;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권11호
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

대형 봉상 접지전극의 접지임피던스와 주파수 응답특성 (Ground Impedance and Frequency Response Characteristics of Large-scale Ground Rods)

  • 이복희;엄주홍;김태두;정동철;길형준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1791-1793
    • /
    • 2003
  • In order to analyze the dynamic characteristics of ground impedance in large grounding system for lightning and surge protections, a novel method for measuring the ground impedance as a function of frequency was proposed. The experiments were carried out in the grounding system composed of ground rods and mesh grids. The test current was injected by the variable frequency inverter whose frequency is linearly controlled in the range of $5{\sim}500$kHz. The ground impedance and frequency response of the grounding system were mainly caused by the inductive current flowing through grounding conductors over the frequency of 2002. In the combined grounding system of rods and mesh grids, inductive component of ground impedance was significantly decreased. It was fumed out that the grounding system is effective for the surge protection.

  • PDF

Isolation, Purification, and Structural Identification of an Antifungal Compound from a Trichoderma Strain

  • Li, Chong-Wei;Song, Rui-Qing;Yang, Li-Bin;Deng, Xun
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권8호
    • /
    • pp.1257-1264
    • /
    • 2015
  • Trichoderma strain T-33 has been demonstrated to have inhibitory effect on the fungus species Cytospora chrysosperma. Here, an active antifungal compound was obtained from Trichoderma strain T-33 extract via combined separation technologies, including organic solvent extraction, liquid chromatography, and thin-layer chromatography. The purified compound was further characterized by advanced analytical technologies to elucidate its chemical structure. Results indicated that the active antifungal compound in Trichoderma strain T-33 extract is 2,5-cyclohexadiene-1,4-dione-2,6-bis (1,1-dimethylethyl).

Texture Image Retrieval Using DTCWT-SVD and Local Binary Pattern Features

  • Jiang, Dayou;Kim, Jongweon
    • Journal of Information Processing Systems
    • /
    • 제13권6호
    • /
    • pp.1628-1639
    • /
    • 2017
  • The combination texture feature extraction approach for texture image retrieval is proposed in this paper. Two kinds of low level texture features were combined in the approach. One of them was extracted from singular value decomposition (SVD) based dual-tree complex wavelet transform (DTCWT) coefficients, and the other one was extracted from multi-scale local binary patterns (LBPs). The fusion features of SVD based multi-directional wavelet features and multi-scale LBP features have short dimensions of feature vector. The comparing experiments are conducted on Brodatz and Vistex datasets. According to the experimental results, the proposed method has a relatively better performance in aspect of retrieval accuracy and time complexity upon the existing methods.

Polynactin Complex (Tetranactin)와 BPMC 혼합제의 사과 및 토양 잔류성 (Residue of Combined Insecticide of Polynactin Complex(Tetranactin) and BPMC in Apple and Soil)

  • 윤재천;이석준;박종우;김장억
    • Current Research on Agriculture and Life Sciences
    • /
    • 제11권
    • /
    • pp.101-110
    • /
    • 1993
  • Tetranactin과 BPMC 혼합유제의 사과 재배 중 살포횟수 및 처리시기에 따른 잔류정도와 토양에 처리한 후의 분해정도를 조사한 결과는 다음과 같다. Tetranactin과 BPMC의 잔류분석시의 회수율은 사과에서 0.5ppm과 1.0ppm의 농도 수준에서 tetranactin은 74.0-77.5% 이었으며 BPMC는 83.6-87.1% 이었다. 토양에서의 회수율은 tetranactin 82.3-84.4%, BPMC 83.6-87.1% 이었다. Tetranactin 및 BPMC의 잔류분석시의 검출한계는 두 약제 모두 사과의 과육 부분에서는 0.01ppm, 사과의 과피 및 토양에서는 0.3ppm 이었다. 사과의 과육 및 과피부분에서 tetranactin 및 BPMC의 잔류량은 수확 3일전 5회 처리에서 잔류량의 96% 정도가 사과의 과피 부분에 잔류되는 것으로 나타났다. 사과에 대한 tetranactin 및 BPMC의 잔류량은 수확 3일전 5회 처리에서 tetranactin은 0.39ppm, BPMC는 0.75ppm이 잔류되어 tetranactin 및 BPMC의 사과에 대한 안전사용기준은 수확 30일전, 2회 이내의 사용으로 추천할 수 있다. Tetranactin 및 BPMC의 토양 중 분해 반감기는 포장시험 조건에서 각각 6.9일과 6.3일 이었으며 실내시험 조건에서는 각각 24.4 및 23.2일로 나타났다.

  • PDF

합류식 관거 내 고형물 퇴적량 산정기법 분석 (Analysis of Estimation Technique for Solid Sediments in Combined Sewer Systems)

  • 이재수
    • 한국수자원학회논문집
    • /
    • 제39권5호
    • /
    • pp.405-415
    • /
    • 2006
  • 건조기 때의 합류식 관거 내 고형물의 퇴적으로 인해 통수능이 감소하여 여름철 장마시 국지적인 침수가 발생하며 이로 인해 관거 내 퇴적을 더욱 초래할 수가 있다. 또한 관거 시스템에 퇴적된 고형물로 인해 우기시 'first-flush' 현상을 초래하기도 한다. 이와 같은 문제를 해결하기 위해서는 장기간에 걸친 관거 내 고형물 퇴적량을 관측할 필요가 있으나 많은 비용과 노력이 수반되어야 한다. 따라서 본 연구에서는 미국환경보호청에서 개발한 건조기의 합류관거 내 고형물 퇴적량 산정기법을 우리나라의 배수유역에 적용하여 분석하였다. 분석결과 적용 배수유역의 가용 자료에 따라 모형을 선택하여 실무에서 간편하게 적용할 수가 있지만 모형별 변수산정 방법별로 많은 차이를 보이고 있다. 초기에 유도된 Eqs. (1)$\sim$(4)가 후에 유도된 Eqs. (5)$\sim$(9)보다 산정치가 모두 크게 나타나고 있으며 전반적으로 중간모형이 정밀모형이나 단순모형보다 크게 나타나고 있다. 건조기 동안의 관거 내 퇴적고형물의 관측자료가 구비되어 있지 않아 실질적으로 비교하기가 곤란하지만 대상 배수유역 관거에서의 장기적인 관측이 이루어지고 이에 따라 국내실정에 맞도록 산정공식의 수정이 이루어지면 실무에서 많은 비용과 노력을 줄이고 관거 관리를 할 수 있다고 판단된다.

소년원학교 학생의 구강건강 실태와 구강건강 인식도 (ORAL HEALTH STATUS AND SELF-PERCEIVED ORAL HEALTH STATUS OF STUDENTS IN JUVENILE PROTECTION EDUCATION INSTITUTIONS)

  • 정영정;정서영;강병진;백광우
    • 대한소아치과학회지
    • /
    • 제36권4호
    • /
    • pp.539-549
    • /
    • 2009
  • 본 연구는 소년원학교 학생의 치아우식증, 치주조직 상태와 구강건강에 대한 실태 및 인식도를 조사하기 위해 경기도 지역 소년원학교에 수용되어 있는 13~20세 남녀 청소년 342명의 우식, 상실, 충전 치아 수와, 상하악 좌우 제1대구치와 상악 우측 중절치, 하악 좌측 중절치의 출혈/치석/치주낭 존재 유무를 검사하였으며, 구강건강에 대한 인식도에 대한 설문조사를 시행하여 다음과 같은 결과를 얻었다. 1. 2006년 국민구강건강실태 조사와 비교할 때, 일반청소년에 비해 소년원학교 학생의 우식 치아, 우식경험 영구치, 출혈, 치석, 천치주낭을 보이는 치아 수가 많았다. 2. 여자가 남자보다 우식경험 영구치 수가 많았으나(p<0.05),건전 치주조직을 보이는 치아 수는 많고, 천치주낭을 보이는 치아 수는 더 적었다(p<0.05). 3. 여자가 남자보다 자신의 구강건강이 나쁘다고 생각하는 비율이 높았으며(p<0.05), 대다수(79.2%) 청소년이 구강건강이 중요하다고 응답하였다. 4. 소년원학교 학생의 71.5%가 치과치료에 대한 불안이 있다고 응답하였으며, 여자가 남자보다 그 비율이 높았다(p<0.05).

  • PDF