• Title/Summary/Keyword: combined loadings

Search Result 87, Processing Time 0.027 seconds

Seismic behavior of reinforced concrete T-shaped columns under compression-bending-shear and torsion

  • Ping, Chen Zong;Weiwei, Su;Yang, Yang
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.431-444
    • /
    • 2021
  • T-shaped column is usually used as side column in buildings, which is one of the weak members in structural system. This paper presented a quasi-static cyclic loading experiment of six specimens of reinforced concrete (RC) T-shaped columns under compression-flexure-shear-torsion combined loadings to investigate the effect in the ratio of torsion to moment (T/M) and axial compression ratio (n) and height-thickness ratio of flange plate (φ) on their seismic performance. Based on the test results, the failure characteristics, hysteretic curves, ductility, energy dissipation, stiffness degradation and strength degradation were analyzed. The results show that the failure characteristics of RC T-shaped columns mainly depend on the ratio of torsion to moment, which can be divided into bending failure, bending-torsion failure and shear-torsion failure. With the increase of T/M ratio, the torsion ductility coefficient increased, and in a suitable range, the torsion and horizontal displacement ductility coefficient of RC T-shaped columns could be effectively improved with the increase of axial compression ratio and the decrease of height-thickness ratio of flange plate. Besides, the energy dissipation capacity of the specimens mainly depended on the bending and shear energy dissipation capacity. On the other hand, the increase of axial compression ratio and the ratio of torsion to moment could accelerate the torsional and bending stiffness degradation of RC T-shaped columns. Moreover, the degradation coefficient of torsion strength was between 0.80 and 0.98, and that of bending strength was between 0.75 and 1.00.

Finite Element Simulation of Hysteretic Behavior of Structural Stainless Steel under Cyclic Loading (반복하중을 받는 스테인리스강의 이력거동 해석모델 개발)

  • Jeon, Jun-Tai
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.2
    • /
    • pp.186-197
    • /
    • 2019
  • Purpose: This study intends to develop a nonlinear cyclic plasticity damage model in the framework of finite element formulation, which is capable of taking large deformation effects into account, in order to accurately predict the hysteretic behavior of stainless steel structures. Method: The new cyclic constitutive equations that utilize the combined isotropic-kinematic hardening rule for plastic deformation is incorporated into the damage mechanic model in conjunction with the large strain formulation. The damage growth law is based on the experimental observations that the evolution of microvoids yields nonlinear damage accumulation with plastic deformation. The damage model parameters and the procedure for their identification are presented. Results and Conclusion: The proposed nonlinear damage model has been verified by simulating uniaxial strain-controlled monotonic and cyclic loading tests, and successfully applied to a thin-walled stainless steel pipe subjected to constant and alternating strain-controlled cyclic loadings.

Numerical analysis of the combined aging and fillet effect of the adhesive on the mechanical behavior of a single lap joint of type Aluminum/Aluminum

  • Medjdoub, S.M.;Madani, K.;Rezgani, L.;Mallarino, S.;Touzain, S.;Campilho, R.D.S.G.
    • Structural Engineering and Mechanics
    • /
    • v.83 no.5
    • /
    • pp.693-707
    • /
    • 2022
  • Bonded joints have proven their performance against conventional joining processes such as welding, riveting and bolting. The single-lap joint is the most widely used to characterize adhesive joints in tensile-shear loadings. However, the high stress concentrations in the adhesive joint due to the non-linearity of the applied loads generate a bending moment in the joint, resulting in high stresses at the adhesive edges. Geometric optimization of the bonded joint to reduce this high stress concentration prompted various researchers to perform geometric modifications of the adhesive and adherends at their free edges. Modifying both edges of the adhesive (spew) and the adherends (bevel) has proven to be an effective solution to reduce stresses at both edges and improve stress transfer at the inner part of the adhesive layer. The majority of research aimed at improving the geometry of the plate and adhesive edges has not considered the effect of temperature and water absorption in evaluating the strength of the joint. The objective of this work is to analyze, by the finite element method, the stress distribution in an adhesive joint between two 2024-T3 aluminum plates. The effects of the adhesive fillet and adherend bevel on the bonded joint stresses were taken into account. On the other hand, degradation of the mechanical properties of the adhesive following its exposure to moisture and temperature was found. The results clearly showed that the modification of the edges of the adhesive and of the bonding agent have an important role in the durability of the bond. Although the modification of the adhesive and bonding edges significantly improves the joint strength, the simultaneous exposure of the joint to temperature and moisture generates high stress concentrations in the adhesive joint that, in most cases, can easily reach the failure point of the material even at low applied stresses.

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

THE CHARACTERISTICS OF CHILD AND ADOLESCENT INPATIENTS WITH SEVERE OBSESSIVE-COMPULSIVE DISORDER (심각한 소아 ${\cdot}$ 청소년 강박장애로 입원한 환아들의 특징)

  • Hwang, Jun-Won;You, So-Young;Chang, Jun-Hwan;Shin, Min-Sup;Cho, Soo-Churl;Hong, Kang-E;Kim, Boong-Nyun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.15 no.2
    • /
    • pp.143-151
    • /
    • 2004
  • Objectives : Child and adolescent onset obsessive compulsive disorder(C-OCD) is known to be associated with poor drug response, high comorbid rate and strong genetic tendencies. Till now studies for C-OCD have been very rare in Korea. We conducted this study to investigate the informations about clinical features, familial psychiatric loading, treatment profiles and course of server C-OCD from the retrospective analysis of inpatient data of Seoul National University Children's Hospital. Method : Retrospective chart review and data analysis was performed. Twenty(male 16 : female 4) patients with final C-OCD diagnosis by DSM-IV at discharge from 1994 to 2002 were found and their medical chart, psychological data, family interview data and nursing reports were collected and analyzed. Results : 1) The sex ratio of C-OCD was male dominant(4:1). 2) Phenomenological, most common obsession was pathologic doubt, contamination fear, followed by aggressive obsession, need for symmetry, sexual obsession, most common compulsion was checking and washing, followed by breathing, movement, symmetry, repetitive asking, hoarding, mental compulsion. 3) Most common comorbid diagnosis was depression. Other axis-I diagnosis associated OCD were anxiety disorder, tic disorder, conduct and oppositional defiant disorder and psychosis. 4) Regarding psychiatric familial loadings, 17 patients(85%) had relatives with psychiatric disorders, OC-spectrum disorders(OCD or OCPD) were found in 9 patients(45%). 5) The majority of patients(75%) have received SSRI and antipsychotics treatment. The response rate above 'moderate improved" by CGI was 75%. 6) During follow-up period in outpatient clinic, five patients(25%) showed continuous complete remission, 10 patients (50%) did residual symptoms with chronic course. Conclusion : This seems to be the first systemic investigation of severe pediatric OCD patients in Korea. The children & adolescents with severe OCD in inpatient-setting showed the high comorbid rate, familial psychiatric loading, and combined pharmacotherapy with antipsychotics, As for symptoms, high rate of aggressive-sexual obsession and atypical compulsions like breathing and moving was reported in this study. Severe pediatric OCD patients, however, responded well to the combined SSRI and antipsychotics regimen.

  • PDF

A Study on the Nonpoint Pollutant Loadings in Urban and Agricultural Areas (도시(都市)와 농촌(農村)에서의 비점원(非點源) 오염물(汚染物) 배출양상(排出樣相)에 관한 연구(硏究))

  • Lim, Bong Su;Lee, Byung Hyun;Choi, Eui So
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.2
    • /
    • pp.45-53
    • /
    • 1984
  • This study was conducted to investigate characteristics of nonpoint pollutant discharges and concentrations in runoff from the urban and agricultural areas in Korea. The analytical parameters used for this study were COD, BOD and SS. This study was conducted during the period from May to August 1981. Nonpoint pollutant mass loadings from the urban area were influenced by the rainfall intensity and the duration of rainfall, and etc. The concentrations of pollutants in the first flush was higher as the discharges increased. It was, however, found that the concentrations of pollutants in the heavy storm runoff were decreased due to the dilution effect. When other rainfall followed a peak rainfall, the concentrations of pollutants were lower than expected, because the first flush conveyed the most of pollutants deposited on the combined sewers. However the concentrations were increased in proportion to the increased flow when a rainfall of higher intensity than the first flush was continued. Yearly area yield rates in kg/ha were estimated to be 690.5(489.9~1,328) of COD, 319.7(226.8~614.8) of BOD, and 831.2(589.7~1,598) of SS. Pollutant sources in agricultural area were of the domestic waste water, manure composting stack, and agricultural solid wastes and etc. In the paddy field, yearly area yield rates in kg/ha were estimated to be 623.4(21.7~114) of COD, 18.65(9.53~34.5) of BOD, and 91.9(46.3~171.8) of SS. In the crop land, however, yearly rates in kg/ha were estimated to be 91.9(46.3~171.8) of COD, 23.09(11.7~42.5) of BOD, and 23.09(11.4~43.4) of SS. Pollutant sources in the feedlot area were originating from the feces of cattle, the cleaning water, the wastes spilled from manure composting stack during rain. Yearly area yield rate in kg/ha was estimated to be 3.804(2,489~6,658) of COD, 2.047(464~2,900) of BOD, and 1.149 (729~1,442) of SS. Pollutant discharges in the forest area were resulted from the organic layer like leaves and others deposited on the surface. Yearly area yield rate in kg/ha was estimated to be 9.86(5.45~18.56) of COD, 3.48(1.67~7.54) of BOD, and 4.64(9.74~10.35) of SS.

  • PDF