• 제목/요약/키워드: combined energy

Search Result 1,913, Processing Time 0.024 seconds

Analysis on the Operational Characteristics of the Combined Generation System with Power Storage Apparatus that Apply Microcontroller

  • Lim, Jung-Yeol;Yoon, Seok-Am;Cha, In-Su
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.12B no.1
    • /
    • pp.24-30
    • /
    • 2002
  • The developments of the solar and the wind power energy are necessary since the future alternative, energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a flew faults with the weather condition. In order to solve these existing problem combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added far the present study. In an experiment, when output of combined generation system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

A Study on the Characteristics of the Combined Generation System by Solar and Wind Energy with Power Storage Apparatus for the Geographical Features

  • Lim, Jung-Yeol;Kang, Byeong-bok;Cha, In-Su
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • The development of the solar and the wind energy is necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently MW Class power generation system has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic and wind power was suggested. It combines wind power energy and solar energy to have the supporting effect from each other. However, since even combined generation system cannot always generate stable output with everchanging weather condition, power storage apparatus that uses elastic energy of spiral spring to combined generation system was also added for the present study.

Development of combined generation systems that power storage apparatus is applied (동력저장장치가 적용된 복합발전시스템의 개발)

  • Lee, Jeong-Il;Seo, Jang-Soo;Kang, Byung-Bog;Cha, In-Su
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The developments of the solar and the wind power energy are neccessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of existing problems, combined generation system of photovoltaic(400W) and wind power generation system(400W) was suggested. It combines wind power and solar energy to have the supporting effect from each other. However, weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator.

Economic Evaluation by Compared Battery Energy Storage System(BESS) and Conventional Combined Cycle of power Generation Cost (복합화력발전시스템과의 발전원가 비교에 의한 전지전력저장시스템의 경제성 분석)

  • Kim, Eung-Sang;Kim, Ji-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.241-246
    • /
    • 1999
  • This paper describes the economic evaluation of battery energy storage system(BESS) for the domestic application. Application target is decided on conventional combined cycle of domestic and we analyzed economics that compared conventional combined cycle with power generation cost in development and the commercialized in case that establish it on utility and customer, urban and rural. The result shows that about the same conventional combined cycle of Anyang, Bundang and Pyungtak but more economical than seoincheon conventional combined cycle. And, in case of capacity enlargment and using the maintenance free battery more economical than conventional system.

  • PDF

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

24 hour Load Forecasting using Combined Very-short-term and Short-term Multi-Variable Time-Series Model (초단기 및 단기 다변수 시계열 결합모델을 이용한 24시간 부하예측)

  • Lee, WonJun;Lee, Munsu;Kang, Byung-O;Jung, Jaesung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.493-499
    • /
    • 2017
  • This paper proposes a combined very-short-term and short-term multi-variate time-series model for 24 hour load forecasting. First, the best model for very-short-term and short-term load forecasting is selected by considering the least error value, and then they are combined by the optimal forecasting time. The actual load data of industry complex is used to show the effectiveness of the proposed model. As a result the load forecasting accuracy of the combined model has increased more than a single model for 24 hour load forecasting.

Operation Mode Development and Evaluation for Grid-Tied PMSG Wind Power System Combined with Battery Energy Storage (배터리 에너지저장이 결합된 계통연계 풍력발전시스템의 운전모드 개발 및 평가)

  • Kim, Hyun-Jun;Kim, Do-Hyun;Kim, Kyung-Tae;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.41-49
    • /
    • 2012
  • This paper describes the operation mode development for the grid-tied PMSG(permanent magnet synchronous generator) wind power system combined with a battery energy storage. The development of operation modes was carried out through simulations with PSCAD/EMTDC software and experiments with a 10kW hardware prototype. The detailed simulation models for PMSG wind power system and battery energy storage were developed using user-defined models programed with C-code. A 10kW hardware simulator was built and tested in connection with the local load and the utility power. The simulation and experimental results confirm that the grid-tied PMSG wind power system combined with battery energy storage can supply highly reliable power to the local load in various operation modes.

Fatigue Design of Mooring Lines of Floating Type Combined Renewable Energy Platforms

  • Choung, Joon-Mo;Jeon, Sang-Ik;Lee, Min-Seong
    • International Journal of Ocean System Engineering
    • /
    • v.1 no.3
    • /
    • pp.171-179
    • /
    • 2011
  • This paper presents the concept design procedure of a floating-type combined renewable energy platform based on hydrodynamic analyses and is focused on the fatigue design of taut-type mooring lines of the platform. Two types of combined renewable energy platforms are considered: a combination of wind turbine, wave turbine and photovoltaic energy plant and a combination of wind turbine, current turbine and photovoltaic energy plant. The basic configurations are conceptually determined from the understanding of floating offshore plants, while the main dimensions have been determined based on a hydrostatic calculation. Fully coupled hydrodynamic analyses have been carried out to identify the motion characteristics of the floating body and the tension histories of the mooring lines. The tension history is used for the fatigue life prediction based on the rain-flow cycle counting method. For the fatigue life prediction, tension life curves from API and the Palmgren-Miner rule are employed.

Evaluation of High Flux Combined with Pretreatment Process for Application of Decentralized Water Supply System with Ceramic Membrane (세라믹 분리막의 분산형 용수공급 시스템 적용을 위한 전처리 연계공정의 고플럭스 평가)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Seongsu;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.61-72
    • /
    • 2018
  • In this study, applicability of the decentralized water supply system were investigated by the high flux evaluation using ceramic membrane with combined pretreatment process. A) filtration process increased the transmembrane pressure of 1.4 kPa and 89.5 kPa on 2 and $5m^3/m^2{\cdot}d$ of filtration flux, respectively, the physical backwashing recovery rate were less than 28.6%. The (B) Coag./Floc. - Sedi. combined process with 4 mg / L of A-PAC showed that the transmembrane pressure increased to within 6 kPa, the physical backwashing recovery rate was over 37.9 % higher than (A) Filtration process. (C) Coag./Floc. combined process showed an increase of transmembrane pressure compared with (B) Coag./Floc. - Sedi. combined process, physical backwashing recovery rate was over 84%. As a result of the membrane fouling analysis using the resistance in series model, the combined pretreatment process showed that the cake resistance (Rc) was more than 92% at membrane filtration flux of $2m^3/m^2{\cdot}d$. In the (C) Coag./Floc. combined process, cake resistance(Rc) was over 86% on high flux conditions. The coagulation floc contained in influent was removed by the membrane, and the cake layer formed with the removed floc was identified as reversible fouling resistance which could be recovered by physical backwashing. The decentralized water supply system, which has the limitation of site area and installation space, is considered to could be operation of high flux of ceramic membrane by applying (C) Coag./Floc. combined process without sedimentation process.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.