Finite Element Analysis of Thermal Fatigue Safety for a Heavy-Duty Diesel Engine (대형디젤엔진의 열적 피로안전도 분석을 위한 유한요소해석)

  • 조남효;이상업;이상규;이상헌
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.122-129
    • /
    • 2004
  • Finite element analysis was performed to analyze structural safety of a new heavy-duty direct injection diesel engine. A half section of the in-line 6-cylinder engine was selected as a computational domain. A mapping method was used to project heat transfer coefficients from CFD results of engine coolant flow onto the FE model. The accurate setting of thermal boundary condition on the FE model was expected to result in improved prediction of temperature, cylinder bore distortion, and stresses. Characteristics of high cycle fatigue were investigated by assuming the engine was operated under the following five loading conditions repeatedly; assembly force, assembly force with thermal loading, alternating maximum gas pressure loading at each cylinder combined with assembly force and thermal loading. Distribution of fatigue safety factor was calculated by using it Haigh diagram in which the maximum and the minimum stresses were selected from the five loading cases.

Re-engineering Distribution Using Web-based B2B Technology

  • Kim, Gyeung-min
    • Journal of Distribution Research
    • /
    • v.6 no.1
    • /
    • pp.22-35
    • /
    • 2001
  • The focus of Business Process Re-engineering (BPR) has been extended to inter-business process that cuts across independent companies. Combined with Supply Chain Management (SCM), inter-business process reengineering (IBPR) focuses on synchronization of business activities among trading partners to achieve performance improvements in inventory management and cycle time. This paper reviews the business process reengineering movement from the historical perspective and presents a case of inter-business process reengineering using the latest internet-based Business-to- Business (B2B) technology based on Collaborative Planning, Forecasting, and Replenishment (CPFR). The case demonstrates how CPFR technology reengineers the distribution process between Heineken USA and its distributors. As world's first implementor of web-based collaborative planning system, Heineken USA reduces cycle time from determining the customer need to delivery of the need by 50% and increases sales revenue by 10%. B2B commerce on the internet is predicted to grow from $90 billion in 1999 to $2.0 trillion in 2003. This paper provides the management with the bench-marking case on inter-business process reengineering using B2B e-commerce technology.

  • PDF

Experimental study on rock-concrete joints under cyclically diametrical compression

  • Chang, Xu;Guo, Tengfei;Lu, Jianyou;Wang, Hui
    • Geomechanics and Engineering
    • /
    • v.17 no.6
    • /
    • pp.553-564
    • /
    • 2019
  • This paper presents experimental results of rock-concrete bi-material discs under cyclically diametrical compression. It was found that both specimens under cyclical and static loading failed in three typical modes: shear crack, tensile crack and a combined mode of shear and wing crack. The failure modes transited gradually from the shear crack to the tensile one by increasing the interface angle between the interface and the loading direction. The cycle number and peak load increased by increasing the interface angle. The number of cycles and peak load increased with the interface groove depth and groove width, however, decreased with increase in interface groove spacing. The concrete strength can contribute more to the cycle number and peak load for specimens with a higher interface angle. Compared with the discs under static loading, the cyclically loaded discs had a lower peak load but a larger deformation. Finally, the effects of interface angle, interface asperity and concrete strength on the fatigue strength were also discussed.

Measurement of the Benefits from Safeguarding Energy Security through Building the Integrated Gasification Combined Cycle Power Plant (석탄가스화 복합발전소 건설의 에너지안보 확보편익 추정)

  • Lim, Seul-Ye;Choi, Hyo-Yeon;Yoo, Seung-Hoon
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.40-47
    • /
    • 2015
  • Integrated gasification combined cycle (IGCC) power plants not only emit less greenhouse gases and air pollutants than conventional coal-fired power plants, but also use low-price, low-quality, and internationally easily procurable coal. Thus we can benefit from safeguarding energy security through building the IGCC power plant. This paper attempts to value the benefits of energy security enhanced by IGCC power plant. To this end, we report here the results from a contingent valuation survey of randomly selected 600 households. A combination of a double-bounded model and a spike model is applied for the purpose of increasing statistical efficiency and dealing with zero(0) willingness to pay data, respectively. The results show that the respondents are additionally willing to pay 6.05 won for 1kWh of electricity generated from IGCC power plant. In other words, the benefits from safeguarding energy security through building the IGCC power plant are 6.05 won per kWh. Given that the expected amount of generation from the Taean IGCC power plant that is scheduled to be built in late 2015 is 2.27 TWh per year, the benefits are estimated to be 13.74 billion won per year.

Characteristics of Thermal and Fluid Flows for Different Fire Locations in Underground Combined Cycle Power Plant (화원 위치에 따른 지하 복합 발전 플랜트 내 열유동 특성 연구)

  • Sung, Kun Hyuk;Bang, Joo Won;Lee, Soyeong;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.716-722
    • /
    • 2017
  • The present study numerically investigates the effect of obstacles located in the trajectory of fire plume flow on heat flow characteristics by using Fire Dynamics Simulation (FDS) software in an underground combined cycle power plant (CCPP). Fire size is taken as 10 MW and two different locations of fire source are selected depending on the presence of an obstacle. As the results, when the obstacle is in the trajectory of fire plume, hot plume arrives at the ceiling about 5 times slower in the upper of the fire in comparison to the results without obstacle. In addition, the average propagation time of ceiling jet increases by about 70 % with the distance from the ceiling in the upper of the fire, and it increases mainly about 4 times at the distance of 10 m. Consequently, it is noted that the analysis of heat flow characteristics in the underground CCPP considering fire scenarios is essential to develop the fire detection system for initial response on evacuation and disaster management.

A Study on the Demonstration of Yellow Plume Elimination System from Combined Cycle Power Plant Using Liquid Injection System (액상 직분사 시스템을 이용한 복합화력 황연제거 실증 연구)

  • Lee, Seung-Jae;Kim, Younghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.317-324
    • /
    • 2020
  • Combined cycle power plants (CCPP) that use natural gas as fuel are easier to start and stop, and have lower pollutant emissions, so their share of domestic power generation facilities is steadily increasing. However, CCPP have a high concentration of nitrogen dioxide (NO2) emission in the initial start-up and low-load operation region, which causes yellow plume and civil complaints. As a control technology, the yellow plume reduction system was developed and operated from the mid-2000s. However, this technology was unable to control the phenomenon due to insufficient preheating of the vaporization system for 10 to 20 minutes of the initial start-up. In this study, CFD analysis and demonstration tests were performed to derive a control technology by injecting a reducing agent directly into the gas turbine exhaust duct. CFD analysis was performed by classifying into 5 cases according to the exhaust gas condition. The RMS values of all cases were less than 15%, showing a good mixing. Based on this, the installation and testing of the demonstration facilities facilitated complete control of the yellow plume phenomenon in the initial start-up.

Numerical Study on Characteristics of Gas Leakage in an Underground Combined Cycle Power Plant (지하 복합발전 플랜트 내부의 가스 누출 특성에 대한 수치해석 연구)

  • Bang, Joo Won;Sung, Kun Hyuk;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.594-600
    • /
    • 2016
  • The present study numerically investigated the gas leakage characteristics in a simplified underground combined cycle power plant. The effect of obstacles near a crack location on the gas concentration in the confined space was analyzed by using the lower flammable limit (LFL) of methane gas. When the jet flow was close to the vertical walls, the longitudinal leakage distance increased by about 60% (when an obstacles was present) compared to the case without any obstacle, because these obstacles prevented transverse flows. In addition, when an air filter was installed near to the trajectory of the gas flow, the longitudinal leakage distance was similar to the distance between the crack and obstacle, whereas the transverse leakage distance increased up to 8 times compared to the case without any obstacle. As the jet flow impacts on the obstacle and changes its direction, the gas flows recirculate. Therefore, it is necessary to consider the effect of the structure and facility locations on the trajectory of the jet flow to propose an accident prevention system in confined spaces.

Numerical Analysis of Gas Leakage and Diffusion Behavior in Underground Combined Cycle Power Plant (지하 복합발전 플랜트 내에서의 가스 누출 및 확산 거동에 관한 수치해석 연구)

  • Bang, Joo Won;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.118-124
    • /
    • 2017
  • In this study, a numerical simulation was performed using commercial code Fluent(v.17.1). The underground Combined Cycle Power Plant (CCPP) was simplified to analyze the methane gas leakage with the crack size and position. In addition, extensive numerical simulations were carried out for different crack sizes from 10 mm to 20 mm. The crack position is the gas leakage, which is assumed to be near the pipe elbow and the gas turbine. A total of 4 cases were compared and analyzed. To analyze the gas leakage, the concept of the Lower Flammable Limit (LFL) was applied. The leakage distance was defined in the longitudinal direction, and the transverse direction was estimated and quantitatively analyzed. As a result, the leakage distance in the longitudinal direction varies by 52.3 % depending on the crack size at the same crack position. Moreover, the maximum difference was 34.8 % according to the crack position when the crack sizes are identical. As jet flow impacts on the obstacle and changes its direction, the recirculation flows are formed. These results are expected to provide useful data to optimize the location and number of gas detections in confined spaces, such as underground CCPP.

A Study on the Theoretical Analysis and Optimal Design Conditions for the $\alpha$ type Stirling Engine ($\alpha$형 스터링 엔진의 최적 설계 조건)

  • 강문규;이택희;유재환
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.142-154
    • /
    • 1998
  • A stirling engine is a mechanism used to convert heat to power and operates on a closed regenerative thermodynamic cycle with compression and expansion of the working fluid at different temperature. The performance of a stilting cycle machine is a function of six independent parameters, namely; (1) speed N(r.p.m), (2) pressure of the working fluid p(Pa), (3) ratio of the temperature in the compression and expansion space ${\tau}(=T_C/T_E)$ , (4) ratio of the swept volumes in these two spaces K, (5) phase angle $\alpha$ and (6) dead volume ratio X. This paper describes the procedure and presents the results of computations carried out to establish the optimum combinations of these six parameters for maximum engine output for the machine acting as a prime mover, over a combined temperature range from $300^{\circ}K$ to $1000^{\circ}K$ and dead volume ratio X ranging from 0.1 to 2.0. The output of a stilting cycle machine can be expressed in terms of nondimensional power in several different ways. Four methods were studied in detail, the parameters optimized and design charts and engine power charts prepared. The results of this paper may be useful as a guide to the likely effects on the performance of some of the important design parameters and regenerator design.

  • PDF

The Effect of Nitriding/DLC Coating on the High Cycle Fatigue Properties of Fe-3.0Ni-0.7Cr-1.4Mn-X Steel (Fe-3.0Ni-0.7Cr-1.4Mn-X강의 고주기피로특성에 미치는 질화/DLC코팅의 영향)

  • Jang, Jae Cheol;Kim, Song-Hee
    • Journal of Surface Science and Engineering
    • /
    • v.49 no.6
    • /
    • pp.587-594
    • /
    • 2016
  • Various surface treatments and thin film coating processes on the surface of injection die steel have been developed to extend the life. Most of previous studies were mainly focused on investigating the wear and static bonding behavior of thin films. In this study complex surface treatments of DLC coating combined with ion nitriding were applied to increase fatigue life and wear resistance. Ion nitriding, DLC coating, and DLC coating following nitriding on the surface of Fe-3.0Ni-0.7Cr-1.4Mn-X steel were investigated to uncover the beneficial effect which is applicable to injection die. The effect of various surface treatments and coating conditions on high cycle fatigue resistance was studied. Surface morphology change during fatigue tests were observed with AFM. Fatigue life of the die steel increased by 10 to 1,000 times at the various level of stress amplitudes in the condition of DLC coating following the ion nitriding for 3 hrs comparing with the only DLC coated condition.