• Title/Summary/Keyword: combination resonance

Search Result 222, Processing Time 0.023 seconds

Seismic Analysis on a Control Panel of (Nuclear) Power Plant (발전소 주 제어실 제어패널의 내진해석)

  • Lee, Heung-Shik;Kim, Myung-Gu;Cho, Chongdu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.6 s.99
    • /
    • pp.652-659
    • /
    • 2005
  • In this paper, seismic qualification analysis for the Plant control Panel is carried out to confirm the structural integrity under the seismic conditions represented by required response spectra(RRS). The finite element method(FEM) is used for the analysis and a mode combination method is adopted to obtain a more reliable spectrum analysis results. In addition, the experimental analysis is performed to compare the reliability of the analytical results. The analysis results shows that the plant control panel system is designed to have the dynamic rigidity with no resonance frequency below 33 Hz. The analytically calculated maximum stress of the plant control panel system is $36\%$ of the field strength of material, thus it can be shown that the system has a stable structure for the seismic load.

Characteristics Analysis of Induction Motor by Operation of Non- linear Loads under the 3-phase 4-wire grid system (3상 4선식에서 비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Wong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.43-48
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Moors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.165-165
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Quantitative Diffusion-Tensor Anisotropy of Human Brain Using Fast STEAM DTI

  • 박현정;황문정;김용선;이상권;장용민
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.138-138
    • /
    • 2001
  • Purpose: To obtain quantitative diffusion-tensor anisotropy information of human cerebral structu using turbo STEAM diffusion-tensor imaging. Method: Quantitative diffusion anisotropy MR images were obtained in 7 healthy adults using turbo STEAM sequence and a combination of tetrahedral and orthogonal diffusi gradients. Both relative anisotropy(RA) and fractional anisotropy(FA) values were measured various brain regions. The anisotropy index was then compared with the reported valu resulting from EPI-based diffusion tensor imaging.

  • PDF

The Diffusion Tensor Imaging of Muscle Preliminary Results

  • 황문정;박현정;장용민;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.167-167
    • /
    • 2001
  • Purpose: To obtain normative human skeletal muscle data and evaluate quantitative diffusion-ten anisotropy information using diffusion-tensor imaging technique. Method: Quantitative extremity muscle diffusion tensor MR images were obtained in 5 healt adults by using turbo STEAM sequence and a combination of tetrahedral and orthogon diffusion gradients. Relative anisotropy(RA) and fractional anisotropy(FA) values we measured in soleus and gastrocnemius muscle in addition to mean ADC value.

  • PDF

Fabrication of metal nanodots and nanowires by atomic force microscopy nanomachining

  • Lin, Heh-Nan
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • The fabrication of metal nanostructures by a combination of atomic force microscopy nanomachining on a thin polymer resist, metal coating and lift-off is reported. Nanodots with sizes and nanowires with widths ranging between 50 and 100 nm have been successfully created. The present work exemplifies the feasibility and effectiveness of using a single-layer resist in comparison with a two-layer resist. In addition, the localized surface plasmon resonance peaks of the metal nanostructures have been measured and the selective growths of zinc oxide nanowires on the metal nanostructures are demonstrated.

  • PDF

Operation Analysis of Induction Motor under the Combination of Linear & Non-linear Loads (선형 및 비선형 부하 혼합 운전시 유도전동기의 동작 분석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Dong-Ju;Kim, Jun-Ho;Lee, Jong-Han;Jeong, Jong-Ho;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.65-67
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Motors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF

Bouble Resonance Optical Pumping in the Transition 5S1/2-5P3/2-4D3/2, 5/2 of Rb Atoms (루비듐 5S1/2-5P3/2-4D3/2, 5/2 전이선에서의 이중공명 광펌핑 분광)

  • Moon, H.S.;Lee, L.;Kim, J.B.
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2005
  • We present the double resonance optical pumping(DROP) spectra according to the laser power, the polarization combination of lasers, and the alignment of lasers in the transition $5P_{3/2}-4D_{5/2}\;and\;5P_{3/2}-4D_{5/2}$ of $^{87}Rb.$ We observed obviously changing DROP spectrum according to the laser power in the transition $5P_{3/2}-4D_{5/2}$ involved the cycling transition. The laser power effects are attributed to the low optical-pumping-effect in the cycling transition. We observed changing DROP spectrum depending on the polarizations of the lasers. The laser polarization effects are attributed to the changing transition probability according to the polarizations of lasers. We compared the co-propagation with the counter-propagation and the spectral linewidths were 12.2 MHz and 6.9 MHz, respectively.

Benefit of Using Early Contrast-Enhanced 2D T2-Weighted Fluid-Attenuated Inversion Recovery Image to Detect Leptomeningeal Metastasis in Lung-Cancer Staging

  • Kim, Han Joon;Lee, Jungbin;Lee, A Leum;Lee, Jae-Wook;Kim, Chan-Kyu;Kim, Jung Youn;Park, Sung-Tae;Chang, Kee-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.32-42
    • /
    • 2022
  • Purpose: To evaluate the clinical benefit of 2D contrast-enhanced T2 fluid-attenuated inversion recovery (CE-T2 FLAIR) image for detecting leptomeningeal metastasis (LM) in the brain metastasis work-up for lung cancer. Materials and Methods: From June 2017 to July 2019, we collected all consecutive patients with lung cancer who underwent brain magnetic resonance image (MRI), including contrast-enhanced 3D fast spin echo T1 black-blood image (CE-T1WI) and CE-T2 FLAIR; we recruited clinico-radiologically suspected LM cases. Two independent readers analyzed the images for LM in three sessions: CE-T1WI, CE-T2 FLAIR, and their combination. Results: We recruited 526 patients with suspected lung cancer who underwent brain MRI; of these, we excluded 77 (insufficient image protocol, unclear pathology, different contrast media, poor image quality). Of the 449 patients, 34 were clinico-radiologically suspected to have LM; among them, 23 were diagnosed with true LM. The calculated detection performance of CE-T1WI, CE-T2 FLAIR, and combined analysis obtained from the 34 suspected LM were highest in the combined analysis (AUC: 0.80, 0.82, and 0.89, respectively). The inter-observer agreement was also the highest in the combined analysis (0.68, 0.72, and 0.86, respectively). In quantitative analyses, CNR of CE-T2 FLAIR was significantly higher than that of CE-T1WI (Wilcoxon signed rank test, P < 0.05). Conclusion: Adding CE-T2 FLAIR might provide better detection for LM in the brain-metastasis screening for lung cancer.

Transmit Receive RF Resonator Optimization at 7 T MRI System (7 T 자기공명영상시스템에서의 송수신 RF 공진기 최적화)

  • Alam, Mohammad Wajih;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1727-1730
    • /
    • 2016
  • Magnetic resonance imaging has a potential to produce clear anatomical as well as functional images of human body. However, the ability to diagnose is limited by signal to noise ratio (SNR) and the resolution of current medical systems. To remove the challenges prevalent due to the use of high field scanners, dedicated radio frequency coils are used. Transverse electromagnetic coils have an advantage of providing homogeneous magnetic field throughout the region but with low signal to noise ratio while surface coils have an advantage of providing higher signal to noise ratio but with low homogeneity. This research combines both the advantage into one by utilizing transmit only transverse electromagnetic radio frequency coils (8 channel) along with receive only surface coils (by varying the number) for better imaging of brain. A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.