• Title/Summary/Keyword: column method

Search Result 3,475, Processing Time 0.031 seconds

Approximate Method to Estimate Member Forces in the Column of a Rigid Frame (강접골조 기둥의 부재력 산정을 위한 근사해석법)

  • Kim, Young-Chan;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4611-4617
    • /
    • 2014
  • This paper proposes an approximate method to estimate member forces of columns in a rigid frame. One of the conventional methods, Cantilever Method assumes the midpoint of a column as a hinge and linear distribution of axial stresses regarding the centroid of the column areas. As a result, it shows erroneous results compared to those of matrix analysis of two frames. In this study, a new method is proposed to estimate the member forces in columns and location of hinges in columns, which can be adopted easily by a practicing engineer, and numerical examples showed improved results compared to conventional methods.

Confounded Row-Column Designs

  • Choi Kuey Chung;Gupta Sudhir
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.313-317
    • /
    • 2004
  • Confounded row-column designs for factorial experiments are studied in this paper. The Designs, thus, have factorial balance with respect to estimable main effects and interactions. John and Lewis (1983) considered generalized cycle row=column designs for factorial experiments. A simple method of constructing confounded designs using the classical method of confounding for block designs is described in this paper

  • PDF

Experimental Study on Supernodal Column Choleksy Factorization in Interior-Point Methods (내부점방법을 위한 초마디 열촐레스키 분해의 실험적 고찰)

  • 설동렬;정호원;박순달
    • Korean Management Science Review
    • /
    • v.15 no.1
    • /
    • pp.87-95
    • /
    • 1998
  • The computational speed of interior point method depends on the speed of Cholesky factorization. The supernodal column Cholesky factorization is a fast method that performs Cholesky factorization of sparse matrices with exploiting computer's characteristics. Three steps are necessary to perform the supernodal column Cholesky factorization : symbolic factorization, creation of the elimination tree, ordering by a post-order of the elimination tree and creation of supernodes. We study performing sequences of these three steps and efficient implementation of them.

  • PDF

An Experimental Study on The Bolted Connection Between H-Beam and Precast-Concrete Column (PC 기둥-H형강보의 볼트접합부에 관한 실험적 연구)

  • 조은영;박순규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.181-185
    • /
    • 2003
  • The composite structural system with reinforced concrete column and steel beam has some advantages in the structural efficiency by complementing the shortcomings between the two systems. The system, however, has also a lot of problems in earthquake-proof capacity and construction process because it is wet method of construction. So, this paper proposed PCS(Precast Concrete Column and Steel Beam) structural system with dry method of construction. Purpose of this study is to enhance merit and control failure mechanism by installing Dog-Bone on H-beam.

  • PDF

Buckling Strength Analysis of Box-Column Including the Coupling Effect Between Local and Global Buckling

  • Paik, Jeom-K.
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1988.10a
    • /
    • pp.36-42
    • /
    • 1988
  • In this study, a formulation of the idealized plate element based upon the idealized structural unit method(ISUM) firstly proposed by Ueda et.al is made in an attempt to analyze the geometric nonlinear behaviour up to the buckling strength of thin-walled long structures like box-column structure including the coupling effect between local and global buckling. An application to the example box-column is also performed and it is found that the present method gives reliable results with consuming very short computing times and therefore is very useful for evaluation of the buckling strength of thin-walled long structures.

  • PDF

A Study on Strength and Packing Characteristics of Top-Down Joint in Field Experiment (현장실험을 통한 역타설 이음부의 강도 및 충전특성에 관한 연구)

  • 강동현;김종구;김병천;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1101-1106
    • /
    • 2000
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is to find a solution of removing void and air, way to exhaust air in top down column. through specimen concrete placing experiment.

GC Capillary Column Installation (가스 크로마토그래피 캐필러리 컬럼 설치 가이드)

  • Matt James;Kirsty Ford
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.2.1-2.6
    • /
    • 2024
  • This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

  • PDF

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.13 no.5
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.

An Elemental Study for construction elevation of a Underground Columns in Top-Down construction Method (TOP-DOWN공법에 의한 지하기둥의 시공성 향상을 위한 기초적 연구)

  • 임형일;박희곤;백민수;조상영;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.1059-1064
    • /
    • 2001
  • This study is about accurate steel column position method in the Top down method's delicate part. When the concrete is placing, it is required that complementary measures to the transformation due to concrete pressure, column buckling, the trouble due to bar net inserting and so on. To solve the problem of exist method, the concrete is placed at the bottom of excavated hole in advance. then, the steel column is inserted into the excavated hole. With a new method try, the problem due to placing pressure and others is could be prevented. In this study, the concrete is examined with test-slump, slump flow, and compressive strength to do quantitative analysis of concrete. The factors of the experiment is plasticizer, retarder addition rate, fly ash substitution rate to cement. Considering of the new method try, the retarder added concrete properties-fluidity, viscosity, strength-is investigated as time lapsing.

  • PDF

Flow Tests of Sandy-Clay Column due to Increasing Water Content and Their Simulation Using Particle Method (함수비 증가에 따른 모래질 점토기둥의 붕괴실험 및 입자법 시뮬레이션)

  • Park, Sung-Sik;Chang, Han
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.11
    • /
    • pp.25-37
    • /
    • 2014
  • Clay or sand does not exist alone but various sizes of soil are mixed in the field. In this study, the effect of water content on large deformation of such mixed soils is studied by using soil column tests and a particle method. A soil column with 7 cm in diameter and 13 cm in height, which was made out of kaolinite with sand content of 0, 10, 25, or 50%, was tested for large deformation. Its deformation was monitored with time. While increasing its water content from 40, 60, to 80%, a total of 12 types of soil column tests were carried out. The particle method simulated their deformation with time. A maximum plastic shear modulus, which was a function of undrained shear strength and plasticity index for soils with different water contents, was associated with soil viscosity to simulate large deformation of soil column. When a sand content of soil column was constant, the deformation of soil column increased with increasing water content. When a water content of soil column was constant, large deformation occurred with increasing the sand content. The maximum deformation, which was 22 cm in diameter, was observed in the case of water content of 80% and sand content of 50%. The particle method was able to relatively well simulate such large deformation and stress change of soils.