• Title/Summary/Keyword: column behavior

Search Result 1,605, Processing Time 0.029 seconds

Optimization of Radiostrontium Separation Process Using Sr Resin (Sr resin을 이용한 방사성 스트론튬 분리의 최적화)

  • Jung, Yoonhee;Kim, Hyuncheol;Suh, Kyung Suk;Kang, Mun Ja;Chung, Kun Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2015
  • For the analysis of 90Sr, which is a pure beta emitter, radiochemical separation from the main interfering elements such as Ca, Ba and Ra is required due to their similarity in chemical behavior to strontium. This study describes a radioanalytical procedure using extraction chromatography for separating Sr from interfering elements. The maximum capacity of the resin for Sr was approximately 6 mg per 1.5 mL of bed volume (BV). The recovery of Sr on the resin 1.5 mL (BV) was quantitative for the calcium level of 200 mg at the flow rate of 1 mL min-1. However the chemical yield declined by increasing the flow rate by up to 5 mL min-1 even at the calcium level of 200 mg. When using the same BV of Sr resin, the performance of the resin was enhanced as the cross-sectional area of the Sr resin column is small.

Progressive collapse of steel-framed gravity buildings under parametric fires

  • Jiang, Jian;Cai, Wenyu;Li, Guo-Qiang;Chen, Wei;Ye, Jihong
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.383-398
    • /
    • 2020
  • This paper investigates the progressive collapse behavior of 3D steel-framed gravity buildings under fires with a cooling phase. The effect of fire protections and bracing systems on whether, how, and when a gravity building collapses is studied. It is found that whether a building collapses or not depends on the duration of the heating phase, and it may withstand a "short-hot" fire, but collapses under a mild fire or a "long-cool" fire. The collapse time can be conservatively determined by the time when the temperature of steel columns reaches a critical temperature of 550 ℃. It is also found that the application of a higher level of fire protection may prevent the collapse of a building, but may also lead to its collapse in the cooling phase due to the delayed temperature increment in the heated members. The tensile membrane action in a heated slab can be resisted by a tensile ring around its perimeter or by tensile yielding lines extended to the edge of the frame. It is recommended for practical design that hat bracing systems should be arranged on the whole top floor, and a combination of perimeter and internal vertical bracing systems be used to mitigate the fire-induced collapse of gravity buildings. It is also suggested that beam-to-column connections should be designed to resist high tensile forces (up to yielding force) during the cooling phase of a fire.

Consolidation Characteristics of Soft Ground with Artesian Pressure (피압에 따른 연약지반의 압밀 거동)

  • Yun, Daeho;Kim, Jaehong;Kim, Yuntae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.2
    • /
    • pp.31-39
    • /
    • 2016
  • Vertical drain has usually been used to accelerate the consolidation of soft clay deposits with high moisture content. Busan thick clay deposits are subjected to artesian pressure from an aquifer in sand and gravel layers. However, effect of artesian pressure existing in drainage-installed soft ground on consolidation behaviors is not well known. This paper investigates the consolidation behavior of drainage-installed soft ground at the Nakdong river estuary with artesian pressure and without artesian pressure. A series of one-dimensional large size column test was carried out to find out the consolidation characteristics of clay. Test results indicated that total settlement of clay with artesian pressure was higher than that without artesian pressure because effective stress decreased due to upward flow. Dissipation rate of excess pore water pressure delayed and excess pore water pressure did not fully dissipate in clay layer with artesian pressure. Undrained shear strength of clay ground with artesian pressure was lower than that without artesian pressure.

Application and Verification of Coupled Analysis of Piled Piers (교량 말뚝기초 해석기법의 적용성 분석)

  • Won Jin-Oh;Jeong Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.123-134
    • /
    • 2005
  • A coupled three-dimensional pile group analysis method (YSGroup) was developed considering nonlinear pile head stiffness matrices and compared with other analytical methods (elastic displacement method, Group 6.0 and FBPier 3.0). In this method, a pile cap was modelled by four-node flat shell element, a pier was modelled using 3 dimensional beam element, and individual piles were modelled as beam-column elements. Through the comparative studies on a piled pie. subjected to lateral loads in linear soil, it was found that present method (YSGroup), elastic displacement method and Group 6.0 gave similar results of lateral pile head displacement, but FBPier 3.0 was estimated to show somewhat larger displacements than those from the three methods. Displacements of superstructure (pier), including nonlinear soil behavior, could be estimated by present method (YSGroup) and FBPier 3.0 because these two methods modelled the superstructure directly by finite element techniques. It was found that pile groups in pinned pile head condition had a tendency to cause excessive rotation of the pile cap.

Dynamic Behavior of Decomposed Granite Soils (화강풍화토의 동적 거동)

  • 이종규
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.1
    • /
    • pp.175-183
    • /
    • 1999
  • Recently, problems related to vibrations of decomposed granite soils have acquired increasing attention in Korea because those soils cover approximately one third of the country. Both resonant column and cyclic triaxial test were performed to investigate deformation characteristics of unsaturated and cement-mixed decomposed granite soils in Suwon region. The important soil parameters in this respect are the shear moduli, dynamic moduli of elasticity and damping ratios. The dynamic parameters are influenced by variables such as strain amplitude, ratio of loading cycles, and degree of saturations, etc. Test results and data have shown that the optimum degree of saturation to the maximum shear modulus due to a capillary menisci effect was about 17~18 % at low strain amplitude and 10~15 % at intermediate strain amplitude. This paper suggests the range of threshold strain and mean shear modulus of decomposed granite soils in Suwon region. It also proposed the empirical relationship between the dynamic parameters for cement-mixed and non-mixed decomposed granite soils.

  • PDF

Coupling Effects in Rainfall-induced Slope Stability Considering Hydro-mechanical Model (강우침투에 의한 비탈면 안정해의 수리-역학적 모델을 이용한 커플링 효과)

  • Kim, Yong-Min;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.9
    • /
    • pp.5-15
    • /
    • 2015
  • In this study, rainfall-induced slope stability and coupling effect are investigated using hydro-mechanical finite element model. This model is developed by formulating constitutive and coupled balance equations and is verified by comparing the numerical results with field matric suction. The homogeneous soil layer (soil column) and soil slope are modeled by this model, and the results of variation in matric suction, mean effective stress, porosity, displacement, factor of safety are compared with those of staggered analysis. It is found that the vertical and horizontal displacement from coupling analysis considering change in porosity is larger than that of staggered analysis. The displacement and matric suction from coupling analysis by rainfall infiltration can affect slope instability, which shows a progressive failure behavior. The lowest factor of safety is observed under short-term rainfall. This results confirm the fact that coupling analysis is needed to design soil slope under severe rain condition.

A Study on the U(VI), Ca(II) and Lu(III) Metal Ions Utilizing Nitrogen-Donator Synthetic Resin (질소-주게 합성수지를 이용한 U(VI), Ca(II) 및 Lu(III) 금속 이온들에 관한 연구)

  • 정만태
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.1
    • /
    • pp.25-33
    • /
    • 2000
  • The new ion exchange resin was synthesized from chloromethylated styrene-1,4-divinylbenzene(DVB) with 1-aza-15-crown-5 macrocyclic ligand by substitution reaction. The effect of pH, time, dielectric constant of solvent and cross-linked of the matrix on the adsorption for $UO_2^{2+}$, $Ca^{2}$ and $Lu^{3+}$ was investigated. The metal ion was not adsorbed on the resins below pH 3 but above pH 4 fast adsorption behavior was showed. The optimum equilibrium time for adsorption of metallic ions was two hours. The adsorption selectivity determined in ethanol matrix was in increasing order $UO_2^{2+}>Ca^{2}>Lu^{3+}$. The adsorption power was in the order of 1%, 2%, 10% and 20% -crosslinked resin, but adsorption properties of resins decreased in proportion to the order of dielectric constant of solvents used. In addition, these metal ions could be separated in the column packed with 1% crosslinked resin by pH2.5 $HNO_3$ as an eluent.

  • PDF

Classification system for figid and semi-rigid connection (강·반강 철골 접합부의 분류체계에 관한 연구)

  • Jang, Mee;Lee, Sang Sup;Mun, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.351-361
    • /
    • 2001
  • The connections are classified as rigid, semi+rigid, or pinned. There are two classification systems, EC3 adn Bjorhovede et al., representatively. The EC3 boundary between rigid and semi-rigid connections is in on the whole restrictive in term of the stiffness as well as the moment capacity of connections. The boundary specified by Bjorhovede et al. may not be sufficient to assure the behavior of rigid frames in some cases. In this study, it is proposed the new classification system for steel connection that depends on the reduction factor(R) of critical buckling load for unbraced semi-rigid frame expressed by the stiffness ratio($\rho$) of beam to column and the stiffness ratio(k) of connection to beam. Finally, it is examined by experimental data that new classification criteria provides a practical boundary compared wit hteh existing classifications.

  • PDF

Behavior of Reduced Beam Section Connectios with Web Openins (웨브 개구부를 갖는 철골 보-기둥 접합부의 내진 성능에 관한 연구)

  • Park, Jong Won;Kang, Seoung Min;Hwang, In Kyu;Kang, Tae Kyoung;Kwon, Ki Ju
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.395-405
    • /
    • 2001
  • A test program was conducted on seismic-resistant steel moment connections constructed using Reduced Beam Sections with beam web openings. In the connection, in order to enhance ductility capacity under severe cyclic loads, a portion of the beam web near the beam-to-column connection is cut out instead of the beam flange as in dogbone connections. A total of 4 large scale specimens were tested in this program. The specimens were all made using $H-458{\times}417{\times}30{\times}50$ sections for the columns and $H-792{\times}300{\times}14{\times}22$ sections for the beams. Test specimens showed excellent performance similar to that of dogbone connections.

  • PDF

Elasto-Plastic Behaviors of Composite Beam using Shear Connectors installed in Driving Pins (드라이빙핀전용 전단연결재를 이용한 합성보의 탄소성 거동)

  • Yang, Il-Seung;Oh, Young-Ho;Lee, Man-Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • The adoption of a composite beam system is regarded as a simple but effective solution because it improves the overall stiffness, strength and stability of the structure by welding shear studs. However, welding shear studs poses problems including electric shock and weld defects. Mechanical methods have emerged as an alternative to metallurgical methods for connecting the H-beam and shear connector. Four specimens were tested in order to compare the structural behavior of the proposed composite beams with that of the classical composite beam given the condition of horizontal loading. With the original composite beam (FCB-SB specimen) using stud bolts, hysteresis loops are stable, but its strength decreased with the crashing of the concrete slab around the column. The suggested composite beams using shear connectors also yielded stable hysteresis loops. Consequently, use of the suggested composite beams instead of the original composite beam are recommended.