• 제목/요약/키워드: column

검색결과 12,353건 처리시간 0.044초

일반 강도 콘크리트 슬래브를 통한 고강도 콘크리트 기둥의 축력 전달 (Transmissibility of High-Strength Concrete Column Loads through Normal-Strength Concrete Slabs)

  • 윤영수;데니스미첼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.521-524
    • /
    • 1999
  • Twelve column specimens were tested in compression, six were slab-column specimens and six were isolated column specimens. The slab column specimens were first tested to punching shear failure before the columns of the specimens were loaded axially. The effects of confinement from the surrounding slab on the axial capacity of the columns was investigated. Other parameters investigated were the placement of fiber-reinforced concrete in the slab and the concentration of flexural reinforcement in the column vicinity.

  • PDF

철근콘크리트 장주 교각의 시간에 따른 거동 (Long-Term Behaviors of Reinforced Concrete Pier Structures Considering Long Column Effects)

  • 정현수;김수만
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.69-72
    • /
    • 2005
  • For reinforced concrete column under sustained loads, the member suffers additional lateral deflection due to creep. This deflection leads to additional bending in the member, which in turn causes the column to deflect still further. Therefore the secondary moment due to additional deflection causes an increase in primary moment and the strength of column is reduced. And also creep buckling may occur. On this study, nonlinear analysis of reinforced concrete long column including crack effects is carried out and then the strength of long column is revaluated.

  • PDF

심층혼합기둥체 차수벽을 이용한 중금속 오염물질의 이동 제어 (Containing Heavy Metal Contaminants Using Soil-Cement Column Barrier)

  • 정문경;천찬란;이주형;김강석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.821-826
    • /
    • 2003
  • Laboratory experiments were peformed to understand physical properties of soil-cement column under the influence of acidic flow including metal contaminants and its retaining capacity against metal migration. The contaminant used in this study was nitric acid with Cu and Cd. The Permeability of soil-cement column decreased when pH of the column began to drop below 12. Decreases in pH led to significant reduction of compressive strength of clayey soil-cement specimen, while relatively marginal reduction for sandy soil-cement specimen. The metal contaminants did not leachate from soil-cement column until pH of soil-cement dropped below 7∼8 for Cu and 9∼10 for Cd. Metal contaminants were precipitated and trapped inside the soil-cement column at pHs higher than those mentioned as verified with metal analysis and visual inspection. This indicated that soil-cement column not only performs well as a cut-off wall, but also helps alleviating the level of contamination of the surrounding environment.

  • PDF

파형강관으로 내부구속된 중공 R.C 교각의 연성도 (Ductility Characteristics of a Hollow R.C Pier Internally Confined by a Corrugated Steel Tube)

  • 한택희;김성남;강영종;정두석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.712-717
    • /
    • 2005
  • When the weight if a concrete member makes problems, or when the cost of the concrete is relatively high, it may be economical to use a hollow concrete member. But a hollow R.C column may have poor ductility because of the brittle failure at the inner face of the hollow R.C column. This brittle failure results from the absence of the confinement at the inner face of the hollow R.C column. To avoid this brittle failure an internally confined hollow R.C column by a steel tube was developed before. In this study, a hollow R.C column is internally confined by a corrugated steel tube instead of a general flat steel tube. And a column ductility is performed. Test results show that the energy ductility ratio of a internally confined hollow R.C column by a by a corrugated steel tube corresponds to $80\%$ of the energy ductility ratio of a general solid R.C column.

  • PDF

매개변수에 따른 기둥축소량 변화에 관한 연구 (Variations of Column Shortening with Parameters)

  • 정은호;김형래
    • 콘크리트학회논문집
    • /
    • 제12권4호
    • /
    • pp.59-67
    • /
    • 2000
  • With increased height of structure, the effect of column shortening need special consideration in the design and construction of high-rise buildings. The shortening of each column affects nonstructural members such as partitions, cladding, and M/E systems, which are not designed to carry gravity forces. The slabs and beams will tilt due to the cumulative differential shortening of adeacent vertical members. The main purpose of estimating the total shortening of vertical structural member is to compensate the differential shortening between adeacent members. This paper presents effect of parameters for phenomenon of column shortening in vertical members. The paper presents effect of parameters for phenomenon of column shortening in vertical members. The conclusions obtained from this study are follow as ; Strength of concrete and steel ratio effected on column shortening caused by elastic and inelastic shortening. Also, it is known that Ultimate-shrinkage-Value, Specific-Creep-Value, and volume to surface ratio effected on inelastic shortening only. Particularly, Ultimate-Shrinkage-Value and Specific-Creep-Value effected considerable on the amount of total column shortening.

Post-buckling behaviours of axially restrained steel columns in fire

  • Li, Guo-Qiang;Wang, Peijun;Hou, Hetao
    • Steel and Composite Structures
    • /
    • 제9권2호
    • /
    • pp.89-101
    • /
    • 2009
  • This paper presents a simplified model to study post-buckling behaviours of the axially restrained steel column at elevated temperatures in fire. The contribution of axial deformation to the curvature of column section is included in theoretical equations. The possible unloading at the convex side of the column when buckling occurs is considered in the stress-strain relationship of steel at elevated temperatures. Parameters that affect structural behaviours of the axial restrained column in fire are studied. The axial restraint cause an increase in the axial force before the column buckles; the buckling temperature of restrained columns will be lower than non-restrained steel columns. However, the axial force of a restrained column decreases after the column buckles with the elevation of temperatures, so make use of the post-buckling behaviour can increase the critical temperature of restrained columns. Columns with temperature gradient across the section will produce lower axial force at elevated temperatures.

분리주탑형 열복합 증류탑에서의 증류실험 (Experimental Distillation Using a Fully Thermally Coupled Distillation Column with Separated Main Columns)

  • 박영민;강현욱;김영한
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1197-1201
    • /
    • 2006
  • In order to improve the operability in a fully thermally coupled distillation column the main column is separated into an upper and a lower column, and its design method is explained. With a distillation experiment using a two-inch column the operability of the proposed column is examined. Readily available methanol, ethanol and propanol are used as the feed, and the experimental result is compared with that of the HYSYS simulation. It is found from the experiment that the recovery ranges between 58.8% and 68% and the distillation efficiency is lower than that of the simulation. consumes less energy than an original column, it is not widely implemented in practice due to its operational difficulty. However, it is proved that the proposed distillation column can be operated without compressors and it can be practically utilized.

Rehabilitation and strengthening of exterior RC beam-column connections using epoxy resin injection and FRP sheet wrapping: Experimental study

  • Marthong, Comingstarful
    • Structural Engineering and Mechanics
    • /
    • 제72권6호
    • /
    • pp.723-736
    • /
    • 2019
  • The efficacy of a technique for the rehabilitation and strengthening of RC beam-column connections damaged due to cyclic loading was investigated. The repair mainly uses epoxy resin infused under pressure into the damaged region to retrieved back the lost capacity and then strengthening using fiber reinforced polymer (FRP) sheets for capacity enhancement. Three common types of reduced scale RC exterior beam-column connections namely (a) beam-column connection with beam weak in flexure (BWF) (b) beam-column connections with beam weak in shear (BWS) and (c) beam-column connections with column weak in shear (CWS) subjected to reversed cyclic loading were considered for the experimental investigation. The rehabilitated and strengthened specimens were also subjected to similar cyclic displacement. Important parameters related to seismic capacity such as strength, stiffness degradation, energy dissipation, and ductility were evaluated. The rehabilitated connections exhibited equal or better performance and hence the adopted rehabilitation strategies could be considered as satisfactory. Confinement of damaged region using FRP sheet significantly enhanced the seismic capacity of the connections.

Experimental and numerical studies on seismic behaviour of exterior beam-column joints

  • Asha, P.;Sundararajan, R.
    • Computers and Concrete
    • /
    • 제13권2호
    • /
    • pp.221-234
    • /
    • 2014
  • A nonlinear finite element analysis using ANSYS is used to evaluate the seismic behavior of reinforced concrete exterior beam-column joints. The behavior of the finite element models under cyclic loading is compared with the experimental results. Two beam-column joint specimens (SH and SHD) with square hoop confinement in joint and throughout the column with detailing as per IS 13920 are studied. The specimen SHD was provided with additional diagonal bars from column to beam to relocate the plastic hinge formation from beam-column interface. The load-displacement relationship, joint shear stress and strain in beam obtained from numerical study showed good agreement with the experimental results. This investigation proves that seismic behaviour of reinforced concrete beam-column joints under reversed cyclic loading can be evaluated successfully using finite element modeling and analysis.

축하중을 받는 ICH-CFT 단면의 비선형 거동 분석 (Nonlinear behavior analysis of ICH-CFT section under axial force)

  • 박종근;한택희;유재홍;강영종
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.291-294
    • /
    • 2008
  • A ICH-CFT colunn(internally confined hollow-concrete filled tube column) has many advantages compare with R.C column and CFT column. For example using a hollow section, it is possible to save material and to reduce self weight of column. Also two steel tubes on both sid of concrete, inner and outter tube, can improve ductility of ICH-CFT column. But study about ICH-CFT section has done only theoretically. Thus although ICH-CFT column has many advantages, ICH-CFT column dosen't use in construction. In this thesis, through out 3-D full modeling using ABAQUS analyze the nonlinear behavaior of ICH-CFT column. And using the analysis result, review the theoretical knowledge.

  • PDF